• 제목/요약/키워드: Ozone generator

검색결과 99건 처리시간 0.024초

가야호 발전기용 SCR System의 성능 평가 (Performance Evaluation of SCR System for Generator Engine on Training Ship KAYA)

  • 정석호;정태영;황성철
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.68-74
    • /
    • 2015
  • NOx emission has been controlled because it is a major cause of the acid rain and effects considerably on formation and destruction of ozone. A SCR system on diesel engine is necessary to clear TierIII, because IMO(International Maritime Organization) plans on tightening regulations to TierIII at $1^{st}$ January 2016. In this study, flow analysis was accomplished with ANSYS Fluent program so that the SCR system would be retrofitted in training ship KAYA and the temperature distributions of exhaust gas in SCR sytem were investigated after it was installed. As a result, it was confirmed that pressure and velocity distributions in SCR system were depended on pipe line shapes, then it was designed as the pressure was lower. The temperature differential between 1 and 3 point was $15^{\circ}C$ because of evaporative latent heat of urea and the temperature of 4 point after catalyst was increased by $5^{\circ}C$ than 3 point because of exothermic reaction.

음이온 발생용 후막형 클러스터의 제조 (Fabrication of Thick Film type Cluster for Anion Generator applications)

  • 조정환;여동훈;신효순;홍연우;박지훈;김종희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.464-464
    • /
    • 2007
  • 환경오염으로 인한 각종 질병 및 증후군 등의 발생으로 가정용 산업용에서 환경관련 기술들이 다양한 분야로 확대되고 있다. 본 연구에서는 양이온 및 음이온 양쪽이온을 최대한 발생시키며, 오존 발생량은 억제하고 소비전력을 절감하고자 Ag-Pd 전극을 적용한 세라믹스 클러스터를 개발하였다. Ag-Pd 전극과 매칭되는 세라믹스 조성을 개발한 후 적층공정 기술을 이용하여 후막형 클러스터를 제조하였다. 전극 패턴모양, 전극간 방전간격 및 전극 보호층의 두께에 따른 음이온 발생량을 측정하여 최적화를 위한 실험을 진행하였으며, 음이온 발생량 100만개이상, 오존발생량 0.6ppb인 특성을 확인하였다.

  • PDF

비열 유전체장벽방전 플라즈마의 포도상구균 및 대장균 살균효과 (Bactericidal Efficacy of Non-thermal DBD Plasma on Staphylococcus aureus and Escherichia coli)

  • 김기영;백남원;김용희;유관호
    • 한국산업보건학회지
    • /
    • 제28권1호
    • /
    • pp.61-79
    • /
    • 2018
  • Objectives: The objective of this study was to examine the effect of non-thermal dielectric barrier discharge(DBD) plasma on decontamination of Staphylococcus aureus(S. aureus) and Escherichia coli(E. coli) as common pathogens. Methods: This experiment was carried out in a chamber($0.64m^3$)designed by the authors. The plasma was continuously generated by a non-thermal DBD plasma generator(Model TB-300, Shinyoung Air tech, Korea). Suspensions of S. aureus and E. coli of 0.5 McFarland standard($1.5{\times}10^8CFU/mL$) were prepared using a Densi-Check photometer(bio $M{\acute{e}}rieux$, France). The suspensions were diluted1:1000 in sterile PBS solutions(approximately$10^{4-5}CFU/mL$) and inoculated on tryptic soy agar(TSA) in Petri dishes. The Petri dishes(80mm internal diameter)were exposed to the non -thermal DBD plasma in the chamber. Results: The results showed that 95% of S. aureus colonies were killed after a six-hour exposure to the DBD plasma. In the case of E. coli, it took two hours to kill 100% of the colonies. The gram-negative E. coli had a greater reduction than the gram-positive S. aureus. This difference may be due to the structure of their cell membranes. The thickness of gram-positive bacteria is greater than that of gram-negative bacteria. The S. aureus is more resistant to DBD plasma exposures than is E. coli. It should be noted that average concentrations of ozone, a byproduct of the DBD plasma generator, were monitored throughout the experiment and the results were well below the criteria, 50 ppb, recommended by the Korean Ministry of the Environment. Thus, non-thermal DBD plasma is deemed safe for use in hospital and public facilities. Conclusions: There was evidence that non-thermal DBD plasma can effectively kill S. aureus and E. coli. The results indicate that DBD plasma technology can greatly contribute to the control of infections in hospitals and other public and private facilities.

코로나 방전-플라즈마 처리수의 틸라피아 순환여과양식시스템 수질 개선 효과 (Improvement of Water Quality by Corona Discharge Plasma-activated Water in a Tilapia Recirculating Aquaculture System)

  • 유진호;문성희;오현지;박태섭;권준영
    • 한국해양생명과학회지
    • /
    • 제5권2호
    • /
    • pp.51-57
    • /
    • 2020
  • 순환여과양식시스템(RAS)은 사육수를 여과하여 재사용하며 고밀도로 사육하는 양식 방법으로 수질관리 및 소독이 매우 중요하다. 병원체로 인한 질병 발생을 예방하고 수질 개선에 도움을 주기 위하여 최근 코로나 방전 플라즈마 처리수(plasma water, PW)를 이용한 사육수 소독법이 제안되었다. 본 연구에서는 플라즈마 발생장치를 설치한 순환여과시스템(처리구, PW system)과 설치하지 않은 순환여과시스템(대조구, No PW system)에서 40일 동안 틸라피아를 사육하면서 수질 변화 및 어체의 성장을 조사하였다. 이를 위해 10일 마다 물을 채수하여 UV 투과율과 일반 세균 수 변화를 측정하였고 틸라피아의 성장지표, 생존율 및 조직학적인 차이를 분석하였다. UV 투과율 실험 결과 처리구와 대조구는 실험 시작 시에(0일) 각각 74.1%, 74.8%를 나타냈으며, 40일째에 처리구는 91.8%로 증가한 반면 대조구는 65.2%로 감소하여 수중 유기물 감소 효과를 확인하였다. 일반 세균 수는 40일에 이르러 처리구(101.69 CFU/ml)에서 대조구(103.25 CFU/ml) 보다 유의하게 감소하였다(p<0.05). 틸라피아 성장차이 조사 결과 처리구는 대조구에 비해 총 증중량이 유의하게 높았으며(p<0.05), 다른 성장지표도 처리구가 상대적으로 높았으나 통계적으로 유의한 차이는 아니었다(p>0.05). 또한 처리구는 100%의 생존율을 보였으며, 조직학적으로 대조구와 차이가 나타나지 않았다. 따라서 플라즈마 처리수는 순환여과양식시스템 내 어류의 성장과 건강에 해를 끼치지 않고 수질 개선에도 효과가 있을 것으로 기대된다. 그러나 현장 적용 시에는 탈기수조의 설치 등 주의사항을 충분히 고려하여야 할 것이다.

전기화학법(電氣化學法)에 의해 생성(生成)된 전해생성(電解生成) 염소(鹽素)를 이용한 루테늄의 침출(浸出) (Leaching of Ruthenium by Electro-generated Chlorine Gas by Electrochemical Method)

  • 안종관;이아름;김민석;안재우;이재령
    • 자원리싸이클링
    • /
    • 제22권6호
    • /
    • pp.55-63
    • /
    • 2013
  • 본 연구에서는 전기화학법으로 생성된 염소를 산화제로 이용하여 루테늄의 침출에 대한 연구를 수행하였다. 휘발성 루테늄산화물의 손실을 막기 위해 전 시스템이 밀폐형으로 제작된다. 루테늄의 침출의 최적조건을 조사하기 위해 pH, 온도, 전해 염소 생성시 인가전류 등의 영향을 조사하였다. 염소전해생성 시스템에 산화전류를 인가하여 염소가스를 발생시키고 침출조에 공급하여 루테늄 용해에 필요한 염소화합물을 생성시켰다. 산화제인 염소화합물의 농도가 포화상태에 도달하였을 때 루테늄 분말시료를 장입하고 침출반응을 진행하였다. 일정시간 간격으로 침출액을 채취하면서 루테늄 침출농도를 분석하였다. 본 실험결과 최적조건은 pH 10, 2 A, $40^{\circ}C$로 이 때 침출률은 88% 이다.

Control Indian meal moth Plodia interpunctella by gas treatment

  • Han, Gyung Deok;Kwon, Hyeok;Jin, Hyun Jung;Kum, Ho Jung;Kim, Bo Hwan;Kim, Wook
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.45-45
    • /
    • 2017
  • The Indian meal moth, Plodia interpunctella, is one of the most important pests of stored food in the food processing industry worldwide. To control the Indian meal moth, methyl bromide, phosphine, high carbon dioxide, sulfuryl fluoride and plant essential oil fumigation have been considered. However, these treatments have disadvantages. For example, depleting the ozone layer, showing resistance in insect, low control efficacy or need high cost for treatment. Chlorine dioxide ($ClO_2$) is strong disinfectant and insecticide. The gas caused a malfunction in enzymes. The oxidative stress induced by $ClO_2$ gas treatment damaged to a physiological system and all life stages of P. interpunctella. The gaseous $ClO_2$ is a convincing alternative to methyl bromide for controlling P. interpunctella. The gaseous $ClO_2$ was generated by a chlorine dioxide generator (PurgoFarm Co., Ltd., Hwasung, Korea). It generated highly pure $ClO_2$ gas and the gas blown out through a vent into a test chamber. Gas entry to the chamber was automatically controlled and monitored by a PortaSene II gas leak detector (Analytical Technology, Collegeville, PA, USA). The properly prepared eggs, larvae, pupae, and adults of P. interpunctella were used in this experiment. Data were analyzed using SAS 9.4. Percentage data were statistically analyzed after arcsine-root transformation. Analysis of variance was performed using general linear model, and means were separated by the least significant difference test at P < 0.05. Fumigation is an effective management technique for controlling all stages of P. interpunctella. We found that $ClO_2$ gas treatment directly effects on egg, larvae, pupae and adults of P. interpunctella. The gas treatment with proper concentration for over a day achieved 100 % mortality in all stages of P. interpunctella and short time treatment or low concentration gas treatment results showed that the egg hatchability, pupation rate, and adult emergency rate were lowered compare with untreated control. Also, abnormal pupae or adult rate were increased. Gaseous $ClO_2$ treatment induced insecticidal reactive oxygen species (ROS), and it resulted in fatal oxidative stress in P. interpunctella. Taken together, these results showed that exposure proper concentration and time of the gas control all stages of P. interpunctella by inducing fatal oxidative stress. Further studies will be required to apply the gas treatment under real-world condition and to understanding physiological reaction in P. interpunctella caused by oxidative stress.

  • PDF

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

담액수경재배 시스템에서 플라즈마수 처리가 상추의 생육 및 페놀류 함량에 미치는 영향 (Effect of Plasma-activated Water Process on the Growth and Functional Substance Content of Lettuce during the Cultivation Period in a Deep Flow Technique System)

  • 노승원;박종석;김성진;김대웅;강우석
    • 생물환경조절학회지
    • /
    • 제29권4호
    • /
    • pp.464-472
    • /
    • 2020
  • 본 연구에서는 플라즈마 발생장치를 수경재배 시스템과 결합하여 재배 기간 동안 처리 시 상추의 생육 및 기능성 물질 함량 변화를 살펴보기 위해 실시하였다. 3주 동안 육묘하여 균일한 크기의 상추 묘를 semi-DFT에 정식하였으며, 플라즈마 공정 장치를 결합하여 4주 동안 8시간 주기로 1시간씩 수중에서 간헐적으로 작동시켰다. 양액(대조구), 플라즈마 활성수(4.2kV, 5.7kV)를 사용하여 온실에서 재배하였으며 이후 수확하여 생육조사 및 기능성 물질 분석을 실시하였다. 플라즈마 활성수 처리 기간 동안 발생되는 활성산소종 중에서 O3로 인하여 플라즈마 발생 장치에 근접한 개체일수록갈색 반점 및 괴사현상이 나타났으며, 생육조사를 실시한 결과 유의적 차이가 나타나지 않았다. 기능성 물질 분석 결과 상추 지상부의 rutin과 총 페놀 함량은 플라즈마수보다 높았지만, epicatechin의 경우 플라즈마수 처리에서 함량이 더 많았다. 근권부에서 측정된 이차대사산물인 rutin, epicatechin, quercetin 및 총 페놀 함량은 대조구보다 플라즈마수 처리구에서 유의하게 높았다. 이러한 결과는 플라즈마수 처리 시간동안 수중에 오존과 같은 활성산소종으로 인해 지상부 생육이 잘 이루어지지 못했으나, 근권 영역에서는 이차대사산물이 크게 증가하였다. 향후 간헐적인 플라즈마 활성수 생성에 따른 생리 장해를 극복하고 뿌리채소의 수경재배 시스템에 적용하여 이차대사산물을 증가시키기 위한 본 기술의 도입이 필요하다.

공기 살균 장치 적용 팽이버섯 재배사의 Listeria Innocua 저감 효과 (Efficacy of Listeria Innocua Reduction on Enoki Mushrooms by Utilization of an Air Sterilization Device)

  • 이현동;유병기;서다솜;김세리;이찬중;곽강수
    • 한국버섯학회지
    • /
    • 제19권3호
    • /
    • pp.210-215
    • /
    • 2021
  • 팽이버섯 재배사의 Listera속 미생물 살균을 위하여 공기 살균 장치가 부착된 파일럿 버섯 재배사를 개발하여 물리적, 화학적 살균처리에 대한 살균 효과 검증실험을 수행하였다. 파일럿 버섯 재배사의 내부 온도는 상부 6.62℃±0.30, 중간 6.46℃±0.24, 하부 6.48℃±0.25, 습도는 79.97%±4.42, 79.43%±4.06, 79.94±4.30%로 설정 온도 6.5℃, 상대습도 75%에 근사하게 제어되었다. 공기 살균 장치 적용에 적합한 팽이버섯 재배단계는 생육단계 조건인 온도 6.5~8.5℃, 습도 70~80% 범위였고 유사 조건에서 이온 클러스터 발생기의 오존 발생농도는 160 ppb 수준으로 나타났다. 물리적 살균처리 후 Listeria innocua의 생존율은 이온클러스터 살균의 경우 0.1~0.9%, UV공기 살균은 9.3~10.6%로 나타났고, 화학적 살균처리인 75% 에탄올과 3% 유기산 수용액 처리구에서는 모두 사멸하는 것으로 나타났다. 소재에 대한 Listeria innocua 생존율은 금속시편의 경우 9.3~10.6%, 플라스틱 권지 9.9~16.2%로 나타났는데, 특히 권지의 거친면에서 생존율이 높게 나타났다. 본 연구 결과에 따르면 버섯 재배사의 Listeria균 발생을 억제하기 위해서 금속 소재로 구성된 재배사 벽면과 재배 선반에 대해서는 이온클러스터 공기 살균처리가 노동력을 절감하면서 살균 가능한 방법이며, 플라스틱 재질의 권지의 경우 화학적 살균처리가 효과적인 것으로 나타났다.