• 제목/요약/키워드: Ozone Concentration

Search Result 758, Processing Time 0.044 seconds

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

Secondary nanoparticle formation by a reaction of ozone and volatile organic compounds emitted from a commercial home cleaner liquid

  • Vu, Thai Phuong;Kim, Sun-Hwa;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • In this study, the formation of nanoparticles by a reaction of ozone with the volatile organic compounds(VOCs) emitted from a commercial home cleaner liquid was investigated using a $1-m^3$ reaction chamber($1{\times}1{\times}1m$). The home cleaner liquid was found to contain many VOCs, particularly terpenes. Some of these VOCs are known to readily react with ozone, forming indoor secondary pollutants. The correlation of particle concentration and reacted ozone concentration was examined with injections of three different ozone concentrations; 50, 100 and 200 ppb. The secondary nanoparticles were formed faster, with their numbers and mass concentrations becoming higher on increasing the concentration of ozone injected.

Prediction of Ozone Concentration by Multiple Regression Analysis in Daegu area (다중회귀분석을 통한 대구지역 오존농도 예측)

  • 최성우;최상기;도상현
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.687-696
    • /
    • 2002
  • Air quality monitoring data and meteorology data which had collected from 1995. 1. to 1999. 2. in six areas of Daegu, Manchondong, Bokhyundong, Deamyungdong, Samdukdong, Leehyundong and Nowondong, were investigated to determine the distribution and characteristic of ozone. A equation of multiple regression was suggested after time series analysis of contribution factor and meteorology factor were investigated during the day which had high concentration of ozone. The results show the following; First, 63.6% of high ozone concentration days, more than 60 ppb of ozone concentration, were in May, June and September. The percentage of each area showed that; Manchondong 14.4%, Bokhyundong 15.4%, Deamyungdong 15.6%, Samdukdong 15.6%, Leehyundong 17.3% and Nowondong 21.6%. Second, correlation coefficients of ozone, $SO_2$, TSP, $NO_2$ and CO showed negative relationship; the results were respectively -0.229, -0.074, -0.387, -0.190(p<0.01), and humidity were -0.677. but temperature, amount of radiation and wind speed had positive relationship; the results were respectively 0.515, 0.509, 0.400(p<0.01). Third, $R^2$ of equation of multiple regression at each area showed that; Nowondong 45.4%, Lee hyundong 77.9%, Samdukdong 69.9%, Daemyungdong 78.8%, Manchondong 88.6%, Bokhyundong 77.6%. Including 1 hour prior ozone concentration, $R^2$ of each area was significantly increased; Nowondong 75.2%, Leehyundong 89.3%, Samdukdong 86.4%, Daemyungdong 88.6%, Manchondong 88.6%, Bokhyundong 88.0%. Using equation of multiple regression, There were some different $R^2$ between predicted value and observed value; Nowondong 48%, Leehyundong 77.5%, Samdukdong 58%, Daemyungdong 73.4%, Manchondong 77.7%, Bokhyundong 75.1%. $R^2$ of model including 1 hour prior ozone concentration was higher than equation of current day; Nowondong 82.5%, Leehyundong 88.3%, Samdukdong 80.7%, Daemyungdong 82.4%, Manchondong 87.6%, Bokhyundong 88.5%.

The Daily Ozone Concentrations at Gwanak and City Hall: Measurement Data between 1996 and 2000 (관악과 시청의 요일별 오존 농도 : 1996∼2000년 측정자료)

  • 김정화;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.611-619
    • /
    • 2003
  • Characteristics of the ozone concentrations in Seoul were analyzed for the data between May and September from 1996 to 2000. Observation data from 27 stations in Seoul are used. Among the results from 27 stations, representative results from 2 stations (City hall and Gwanak representing downtown and background areas of Seoul, respectively) are presented. The 24-hour average ozone concentrations of Gwanak (28.6 ppb) are higher than City hall (14.9 ppb). The 24-hour average ozone concentrations on Sunday are higher than other days at both sites. During weekday, the 24-hour average ozone concentrations on Wednesday are higher than other days. Although the mean of the I-hour daily maximum ozone concentrations at Gwanak is higher than City hall, the . ozone concentrations above 95th percentile at City hall are higher than Gwanak. As a result, the number of days on which the 1 - hour ozone concentration exceeding 100 ppb and 120 ppb at Gwanak (17 and 3) are lower than City hall (29 and 9). To sum up, both sites are VOCs limited region and the mean ozone concentration in Gwanak is higher because of the lower N0$_2$ concentration. But high ozone cases occur more frequently in City hall when conditions are right.

Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan (2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성)

  • Jeon, Byung-Il;Oh, In-Bo
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

Observation and Characteristics of Ozonizer using Injection Needle Electrode (주사바늘 전극형 오존발생기 특성 연구)

  • Park, Hyun-Mi;Kwon, Young-Hak;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

Forecasting Ozone Concentration with Decision Support System (의사 결정 구조에 의한 오존 농도예측)

  • 김재용;김성신;이종범;김신도;김용국
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.19-22
    • /
    • 2000
  • In this paper, we present forecasting ozone concentration with decision support system. Forecasting ozone concentration with decision support system is acquired to information from human knowledge and experiment data. Fuzzy clustering method uses the acquisition and dynamic polynomial neural network gives us a good performance for ozone prediction with ability of superior data approximation and self-organization.

  • PDF

Effects of Ozone on Photosynithetic Activity in Chloroplast of Barley (Hordeum vulgare L.) (오존이 보리(Hordeum vulgare L.) 엽록체의 광합성 활성에 미치는 영향)

  • 정화숙
    • Journal of Plant Biology
    • /
    • v.38 no.4
    • /
    • pp.399-407
    • /
    • 1995
  • The effects of 0.5 and 1.0 ppm of ozone on the developing chloroplast of barley (Hordeum vulgare L) seedling during greening were investigated by PSI and II activities, chlorophyll fluorescence, and the contents of chlorophyll. Etiolated barley seedling was treated 0.5 and 1.0 ppm ozone for the first 4 h during greening. In 24 h greening experiment, the contents of chlorophyll were decreased by increasing ozone concentration from 0.5 ppm to 1.0 ppm. In 24 h greening experiment, Fo, Fv, Fm and qE were greatly decreased as the concentration of ozone was increased, but those were not considerably decreased in 48 h greening experiment. In another experiment, the developing barley seedling was treated with 0.5 and 1.0 ppm ozone for the last 4 h during greening period, which was 24 h or 48 h. In both experiments the PS II activity was decreased as the concentration of ozone was increased, but not in PS I activity. Fv, Fm and Fv/Fo were also decreased as the concentration of ozone was increased. qP and qR were strikingly decreased as the concentration of ozone was increased in both experiments.iments.

  • PDF

Construction and Evaluation of $O_3$ Condensation System for Oxide Thin Film (산화 박막 성장을 위한 $O_3$ 농축 시스템의 구축 및 평가)

  • Lim, Jung-Kwan;Ryu, Sun-Jong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1192-1195
    • /
    • 2003
  • A highly condensed ozone gas be transferred to the superconductor thin film growth chamber because ozone is strong oxidizing gas. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure.

  • PDF

Growth, Physiological Responses and Ozone Uptake of Five Betula Species Exposed to Ozone

  • Lee, Jae-Cheon;Han, Sim-Hee;Kim, Pan-Gi;Jang, Suk-Seong;Woo, Su-Young
    • The Korean Journal of Ecology
    • /
    • v.26 no.4
    • /
    • pp.165-172
    • /
    • 2003
  • The objectives of this study were to examine the physiological responses to ozone and to measure ozone uptake rates of Betula species exposed to relatively high concentration of pollutants. At the end of the growing season, photosynthesis, pigments contents, antioxidants (SOD and GR) and ozone uptake rates were measured or estimated at the leaves of five Betula species (Betula costata, B. davurica, B. platyphylla var. japonica, B. schmidtii and B. ermanii) exposed to 100ppb ozone concentration. On the termination of the experiment, growth effects were determined by measuring leaf area and dry weights of leaf, stem and root. Ozone treatment showed the significant reduction the leaf area and dry weight of four Betula species, except for B. ermanii. Shoot / root (SR) ratio of five species represented two different types. SR ratio of B. costata and B. davurica were lower than control, in contrast, SR ratio of B. platyphylla var. japonica, B. schimidtii and B. emani, were higher than that of control. The photosynthetic responses of five species were different in responses to ozone exposure. Four species, except for B. emanii, maintained or increased the stomatal conductance, but B. emanii decreased both stomatal conductance and photosynthesis. SOD activities of five species decreased by the ozone exposure, especially B. ermanii showed the largest reduction, GR activities of B. platyphylla var. japonica and B. schmidtii increased, B. costata and B. emanii decreased. Instantaneous ozone uptake rate was the highest at the leaves of B. ermanii and B. costata, ozone uptake per seedling was the highest at the leaf of B. schmidtii and B. emanii. It was concluded that B. costata, B. davurica and B. platyphylla var. japonica, appeared the growth reduction and visible ozone injury, were sensitive species to ozone, and B. schmidtii with the increased antioxidant activity and B. ermanii without the growth reduction were relatively resistant species to high ozone concentration at the early growing stage.