• Title/Summary/Keyword: Oxygen membrane

Search Result 880, Processing Time 0.022 seconds

Effect of Change in Wet/Dry Time of PEMFC Membrane Durability Test Protocol Using Oxygen as Cathode Gas (Cathode 산소 공급조건에서 고분자막 내구평가 프로토콜의 가습/건조 시간 변화의 영향)

  • Lim, Daehyeon;Oh, Sohyeong;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.16-20
    • /
    • 2021
  • Since the durability evaluation for improving the durability of PEMFC polymer membranes is very important for the development of PEMFC, research and development of the polymer membrane durability evaluation protocol (AST) continues. Recently, DOE's polymer membrane chemical/mechanical durability evaluation AST was developed and applied to Nafion XL for review. In order to shorten the evaluation time, oxygen was used as a cathode gas instead of air, and it was finished in 144 hours. Since DOE AST has a large number of voltage changes with 45 seconds of humidification and 30 seconds of drying, the degradation of the electrode has more influence on the MEA durability. Therefore, one cycle time was lengthened with 60sec of wet/300sec of dry, and the drying time was made longer than the humidification time to further deteriorate the polymer membrane, and it was finished in 240 hours. It was confirmed that the DOE AST for evaluation of the durability of the polymer membrane was accompanied by electrode degradation.

Cysteine improves boar sperm quality via glutathione biosynthesis during the liquid storage

  • Zhu, Zhendong;Zeng, Yao;Zeng, Wenxian
    • Animal Bioscience
    • /
    • v.35 no.2
    • /
    • pp.166-176
    • /
    • 2022
  • Objective: Sperm is particularly susceptible to reactive oxygen species (ROS) stress. Glutathione (GSH) is an endogenous antioxidant that regulates sperm redox homeostasis. However, it is not clear whether boar sperm could utilize cysteine for synthesis GSH to protect sperm quality from ROS damage. Therefore, the present study was undertaken to elucidate the mechanism of how cysteine is involved in protecting boar sperm quality during liquid storage. Methods: Sperm motility, membrane integrity, lipid peroxidation, 4-hydroxyIlonenal (4-HNE) modifications, mitochondrial membrane potential, as well as the levels of ROS, GSH, and, ATP were evaluated. Moreover, the enzymes (GCLC: glutamate cysteine ligase; GSS: glutathione synthetase) that are involved in glutathione synthesis from cysteine precursor were detected by western blotting. Results: Compared to the control, addition of 1.25 mM cysteine to the liquid storage significantly increased boar sperm progressive motility, straight-line velocity, curvilinear velocity, beat-cross frequency, membrane integrity, mitochondrial membrane potential, ATP level, acrosome integrity, activities of superoxide dismutase and catalase, and GSH level, while reducing the ROS level, lipid peroxidation and 4-HNE modifications. It was also observed that the GCLC and GSS were expressed in boar sperm. Interestingly, when we used menadione to induce sperm with ROS stress, the menadione associated damages were observed to be reduced by the cysteine supplementation. Moreover, compared to the cysteine treatment, the γ-glutamylcysteine synthetase (γ-GCS) activity, GSH level, mitochondrial membrane potential, ATP level, membrane integrity and progressive motility in boar sperm were decreased by supplementing with an inhibitor of GSH synthesis, buthionine sulfoximine. Conclusion: These data suggest that boar sperm could biosynthesize the GSH from cysteine in vitro. Therefore, during storage, addition of cysteine improves boar sperm quality via enhancing the GSH synthesis to resist ROS stress.

Controlled Release of Insulin through Glucose Oxidase Immobilized Composite Poly(vinyl Alcohol)/Chitosan Blend Membrane (글루코오즈가 고정화된 Poly(vinly Alcohol)/Chitosan 블렌드 복합막을 통한 인슐린의 방출조절)

  • Kim, Jin Hong;Shim, Jin Ki;Lee, Young Moo;Son, Tae Il
    • Membrane Journal
    • /
    • v.3 no.2
    • /
    • pp.70-78
    • /
    • 1993
  • The permeation of insulin was conducted through glucose oxidase(GOD) immobilized composite membrane composed of poly(vinyl akohol)/chitosan blend and porous polyamide membrane. The permeation coefficient of insulin through GOD-immobilized membrane was in the order of $10^{-6}{\sim}10^{-7}\textrm{cm}^3cm/\textrm{cm}^2sec$. The sensitivity of the composite membrane to the glucose concentration was high in a low glucose concentration resulting from the oxygen depletion from the membrane. The permeation of insulin through composite membrane made of PVA/chitosan and porous polyamide membrane was changed by pH and glucose concentration. The permeability was progressively increasing with the glucose concentration at least up to 500mg%.

  • PDF

Recent Progress in Zeolite Membrane for Wastewater Treatment: A Review (폐수처리를 위한 제올라이트 막의 최근 연구에 대한 총설)

  • Lee, Joo Yeop;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.227-234
    • /
    • 2022
  • Wastewater is released from leather, textile, paint, wood, or dye processing industries as well as petroleum refining industries. Wastewater from these industries contains water pollutant such as heavy metals and nitrogen compounds and has high chemical oxygen demand (COD). While there various filtering pollutants from wastewater for safe disposal, membrane-based technology is one of the most efficient methods for its high efficiency and low cost. Among various membranes, zeolite membranes gain spotlight for its cost-effectiveness and have undergone a lot of research. This review is focused on recent progress in zeolite membrane for wastewater treatment in following order: i) wastewater treatment, ii) microfiltration membrane, iii) hollow fiber membrane, and iv) ultrafiltration membrane.

Effect of pH, Saturated Oxygen, and Back-flushing Media in Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst-loaded PES Beads (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성수처리에서 pH 및 포화산소, 역세척 매체의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2014
  • The effects of pH, saturated oxygen, and back-flushing media were investigated in hybrid process of tubular ceramic microfiltration and $TiO_2$ photocatalyst-loaded PES (polyethersulfone) beads for advanced drinking water treatment, and compared results of water, nitrogen, or oxygen back-flushing in the viewpoints of membrane fouling resistance ($R_f$), permeate flux (J) and total treated water ($V_T$). $R_f$ decreased, and J and $V_T$ increased as decreasing pH. Turbidity treatment efficiencies were similar at water or nitrogen back-flushing independent of pH, but DOM (dissolved organic matter) treatment efficiency did not have a trend at water back-flushing. $R_f$ at NBF (no back-flushing) with SO (saturated oxygen) was the lower than that at NBF without SO. Also, the DOM treatment efficiency at NBF with SO was the lower than that at NBF without SO. It happened because OH radicals produced by reaction of SO and photocatalyst could dilute with water inside the module. The DOM treatment efficiency of gas back-flushing showed the larger than that of water back-flushing at back-flushig period 10 min. It proved that the adsorption or photo-oxidation of PES beads could be activated by the more effective bead-cleaning of gas back-flushing than water back-flushing.

Oxygen Permeation Properties of Tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) Membranes under Different Condition of Feed Side and Permeate Side (공급 측과 투과 측 조건에 따른 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) 관형 분리막의 산소투과 특성)

  • Kim, Jong-Pyo;Park, Jung-Hoon;Lee, Yong-Taek;Choi, Young-Jong
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.155-162
    • /
    • 2011
  • Dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) membranes were prepared by extrusion technique. The phase structure of the $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membranes was characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). Relative density of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ tubular membrane was 94.10%. Oxygen permeation was measured at difference operating condition of feed side and permeate side in the temperature range from 700 to $950^{\circ}C$. The oxygen permeation flux of dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane reached maximum 1.37 mL/$min{\cdot}cm^2$ at $900^{\circ}C$ exposed to ambient air (feed side) and vacuum pump (permeate side).

Oxygen Permeation and Mechanical Properties of La0.6Sr0.4Co0.2Fe0.8O3-δ Membrane with Different Microstructures (미세구조에 따른 La0.6Sr0.4Co0.2Fe0.8O3-δ 분리막의 산소투과 및 기계적 특성)

  • Lee, Shi-Woo;Lee, Seung-Young;Lee, Kee-Sung;Woo, Sang-Kuk;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.994-1000
    • /
    • 2002
  • Oxygen permeability and the mechanical properties of mixed ionic-electronic conductive $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ perovskite-type membrane, fabricated by solid state reaction, were investigated with regard to microstructure. The microstructure of the membrane was controlled by changing the sintering temperature and holding time. The average grain size and relative density were evaluated as a function of sintering conditions. As the fraction of grain boundary decreased, oxygen permeability showed a tendency to increase. Especially the maximum oxygen flux of 0.37 ml/$cm^2$${\cdot}$min was measured for the specimen sintered at 1300${\circ}C$ for 10 h, which has high density and relatively large grain size. Fracture strength was dependent on the relative density of sintered body, while fracture toughness increased with average grain size.

A Study on the Microfabricated Clark-type Sensor for Measuring Dissolved Oxygen (용존 산소 측정용 초소형 Clark-type 센서에 대한 연구)

  • Park, Jung-Il;Chang, Jong-Hyeon;Choi, Myung-Ki;Lee, Dong-Young;Kim, Young-Mi;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1450-1454
    • /
    • 2007
  • This paper presents a microfabricated Clark-type sensor which exactly can measure dissolved oxygen in the cell containing solution. We designed, fabricated, and characterized a microfabircated Clark-type oxygen sensor for measuring dissolved oxygen. The microfabricated oxygen sensor consists of 3-electrodes on a glass substrate, a FEP (Fluorinated ethylene propylene) oxygen-permeable membrane, and PDMS (Polydimethylsiloxane) reservoir for storing sample solution. Thin-film Ag/AgCl was employed as a reference electrode and its durability was verified by obtaining a stable open circuit potential for 2 hours against a commercial Ag/AgCl electrode and a stable cyclic voltammetry curve. Selectivity, response time, and linearity of the fabricated oxygen sensor were also verified well by cyclic voltammetry and amperometry depending. The fabricated oxygen sensor showed a 90% response time of 40sec and an excellent linearity with a correlation coefficient of 0.994.

Nanofiltration of Dyeing Wastewater Using Polyamide Ro-Membranes after the Pretreatment with Chemical Coagulants

  • Hwang Jeong-Eun;Jegal Jonggeon;Mo Joonghwan;Kim Jaephil
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.58-66
    • /
    • 2005
  • Nanofiltration (NF) of a dyeing wastewater was carried out using polyamide NF-membranes. Before applying the wastewater to the membrane process, it was pretreated with various chemical coagulants such as alum, ferric chloride and HOC-100A. In order to see the effect of the pretreatment of the wastewater using chemical coagulants on the membrane separation process, the optimum conditions for the coagulation and sedimentation process using the chemical coagulants were sought. By the pretreatment, despite the different coagulants used, the chemical oxygen demand (COD) and UV-absorbance of the wastewater were lowered by more than $70\%$. The pretreated wastewater was then applied to the membrane process. The effect of the coagulants used for the pretreatment on the membrane fouling was studied. From this study, it was found that the HOC-100A was the best out of the coagulants used far the removal of the materials that could cause membrane fouling.

Synthesis and Characterization of Alumina Composite Membrane by Al Evaporation and Thermal Oxidation (알루미늄의 진공증발과 열산화에 의한 알루미나 복합분리막의 제조 및 특성분석)

  • 이동호;최두진;현상훈
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.349-358
    • /
    • 1995
  • The ceramic composite membrane was synthesized by thermal oxidation after evaporation of Al on the support prepared by slip casting process. Oxidation was performed at $700^{\circ}C$ and 80$0^{\circ}C$ under dry oxygen atmosphere. It was considered as optimum oxidation condition that the membrane showed a knudsen behaviro. A further oxidation resulted in an increase of gas permeability because top layer became densified. Then, a multi-layered composite membrane was synthesized through a sol-gel method, evaporation and thermal oxidation of Al coating processes. While the membrane was thermally stable up to 80$0^{\circ}C$, gas permeability was rapidly decreased even at a slight amount of deposition of Al.

  • PDF