• 제목/요약/키워드: Oxygen flow rate

검색결과 689건 처리시간 0.022초

Protective Effect of Ginsenoside R0 on Anoxic and Oxidative Damage In vitro

  • Jiang, Zhou;Wang, Yuhui;Zhang, Xiaoyun;Peng, Tao;Li, Yanqing;Zhang, Yi
    • Biomolecules & Therapeutics
    • /
    • 제20권6호
    • /
    • pp.544-549
    • /
    • 2012
  • To examine the neuroprotective effects of ginsenoside R0, we investigated the effects of ginsenoside R0 in PC12 cells under an anoxic or oxidative environment with Edaravone as a control. PC12 neuroendocrine cells were used as a model target. Anoxic damage or oxidative damage in PC12 cells were induced by adding sodium dithionite or hydrogen peroxide respectively in cultured medium. Survival ratios of different groups were detected by an AlamarBlue assay. At the same time, the apoptosis of PC12 cells were determined with flow cytometry. The putative neuroprotective effects of ginsenoside R0 is thought to be exerted through enhancing the activity of antioxidant enzymes Superoxide dismutases (SOD). The activity of SOD and the level of malondialdehyde (MDA) and intracellular reactive oxygen species (ROS), were measured to evaluate the protective and therapeutic effects of ginsenoside R0. Ginsenoside R0 treated cells had a higher SOD activity, lower MDA level and lower ROS, and their survival ratio was higher with a lower apoptosis rate. It is suggested that ginsenoside R0 has a protective effect in the cultured PC12 cells, and the protection efficiency is higher than Edaravone. The protective mechanisms of these two are different. The prevent ability of ginsenoside R0 is higher than its repair ability in neuroprotection in vitro.

ECR PECVD법에 의한 페로브스카이트상(Pb, La)$\textrm{TiO}_3$ 박막 증착 연구 (A Study on the Fabrication of Perovskite (Pb, La)$\textrm{TiO}_3$ Thin Films by ECR PECVD)

  • 정성웅;박혜련;이원종
    • 한국재료학회지
    • /
    • 제7권1호
    • /
    • pp.33-39
    • /
    • 1997
  • ECR PECVD법에 의해 $Pt/Ti/SiO_{2}/Si$ 다층 기판 위에 $480^{\circ}C$에서 순수한 페로브스카이트상의 PLT박막을 증착하였다. PLT 박막 증착전 ECR산소 플라즈마내에서의 $Pb(DPM)_{2}$ pre-flowing처리는 $Pb(DPM)_{2}$의 공급을 안정화시켜주며 박막증착초기에 Pb성분이 풍부한 분위기를 조성해 줌으로써 페로브스카이트 핵생성을 용이하게 하여 PLT박막 특성을 향상시켰다. Ti-source 유입량을 변화시킬 때 PLT박막의 증착특성, 조성, 결정상 그리고 전기적 특성을 관찰하였다. PLT박막은(100)으로 우선 배향되었으며 화학양론비가 잘 맞는 경우 높은 페로브스카이트 X-선 회절강도와 높은 유전율을 나타내었다.

  • PDF

오존($O_{3}$)을 이용한 면직물의 표백에 관한 연구 (A Study on the Bleaching of Cotton Fabrics by utilizing Ozone(($O_{3}$))

  • Cho, Hwan;Seo, Mal Young;Yu, Jae Sun;Lee, Byung Hyun;Huh, Man Woo;Lee, Kwang Woo;Cho, In Sul;Jong, Hee Cheon
    • 한국염색가공학회지
    • /
    • 제5권4호
    • /
    • pp.49-59
    • /
    • 1993
  • In order to study the bleaching of cotton fabrics, ozone which has been produced by an ozone generator, has been contacted with cotton fabrics in water at various conditions. The equipments used for the ozone treatment of cotton fabrics were the ozone generator and a liquor/ozone contactor. For the examination of the ozone bleaching effect on cotton fabrics the whiteness, tensile strength, wettability and clark softness of the ozone treated cotton fabrics were measured. The conclusion obtained were, ozone concentration was increased, as the voltage was increased and flow rate was decreased and oxygen amount was increased. Bleaching effect of treated fabrics increased with increasing attributed more the net concentration of ozone rather than the total ozone amount of produced. The whiteness of treated fabrics was found to be best when treating temperature was 15~20<$^{\circ}C$, in acidic condition. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised, and the acidity increased. The wicking distance of treated fabrics increased slightly with increasing the treating time and the temperature. Clark softness of treated fabrics was not changed until passing 30min. of the treating time, then it decreasing linealy with increasing the treating time.

  • PDF

폐플라스틱용기 미디어를 활용한 오수고도처리 (Advanced Treatment of Sewage Using Waste Plastic Vessel Media)

  • 김재용;엄명헌;안대현;심명진
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.58-61
    • /
    • 2006
  • 본 연구는 폐플라스틱용기 미디어 산화공법을 이용하여 유체 및 산소전달 효율 향상을 위한 개조 방법과 미생물 부착특성을 향상시키는 방법을 통하여 오수고도처리 함을 목적으로 하고 있다. 또한 실험실 규모의 실험에서 최적의 담체 층진율과 충진 방법을 도출함으로써, 실 규모 설비를 위한 최적 설계 인자와 운전인자를 확보하고, 오수의 고도처리를 위한 다양한 운전조건을 제공하여 폐플라스틱 용기를 미생물 담체로 사용할 경우 생물학적 반응에 의해서 분해 될 때 소비되는 산소량과 오수중에 현탁되어 있는 유, 무기성 부유물과 질소 제거가 이루어지는 메카니즘을 규명하고 오수 처리 효율 향상을 위한 운전인자 도출을 목표로 한다.

알콜증류폐액을 이용한 빵효모배양에서 포도당, 암모늄 및 인산의 자동첨가에 의한 증균 (Increasing Cell Concentration by the Automatic Addition of Glucose, Ammonium and Phosphate in the Cultivation of a Baker′s Yeast in Alcohol Distillery Wastewater)

  • 이형춘
    • KSBB Journal
    • /
    • 제18권3호
    • /
    • pp.197-201
    • /
    • 2003
  • 알콜증류 폐액에 빵효모를 배양하는 중에 포도당, 암모늄 및 인산을 자동 첨가하여 균체량을 효율적으로 증가시킴으로써 폐액의 재이용성을 향상시키고자 하였다. 포도당은 DO를 제어파라미터로 하는 제어방법을 사용하여 자동 첨가함으로서 그 농도를 300 mg/L 이하로 유지하였다. 암모늄은 pH-stat 방법을 사용하여 N $H_4$OH로서 자동 첨가함으로서 12.6~17.4mM의 낮은 농도범위로 유지하였다. 인산의 경우에는 분석방법으로써 ascorbic acid법을 채택한 자동화 FIA sysetm을 제작하여 사용하였다. 이 system으로 배양 19.4 시간 후부터 배양액을 자동분석하고 제어한 결과 배양액의 P $O_4$-P 농도를 23.3~43.4 mg/L 의 낮은 농도범위로 유지할 수 있었다. 세가지 영양성분을 자동첨가하면서 배양한 결과 증식의 정체없이 균체량을 33.0배 더 증가시킬 수 있었다. 비증식속도는 0.19 $hr^{-l}$였다.

기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성 (Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제30권4호
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

하수처리 전산모사 프로그램을 통한 연계처리시 하수처리장 영향 평가 (Evaluation of the impact of sewage treatment plants in the Linked treatment through the sewage treatment computer simulation program)

  • 김성지;길경익
    • 한국습지학회지
    • /
    • 제22권4호
    • /
    • pp.321-327
    • /
    • 2020
  • 산업발전과 인구증가, 생활수준의 향상으로 하·폐수 발생량 및 하수처리장 연계처리수가 매년증가 하고 있다. 연계처리수는 저유량 고농도의 특징을 가지고 있다. 따라서 하수처리장 운영에 큰 영향을 미치고 연계처리수를 처리하기 위해 많은 비용도 사용되는 것으로 나타났다. 본 연구에서는 연계처리수의 유입 유량을 개별 반응조로 전량 유입시킬 경우 방류수 수질이 적게 상승한 시나리오를 도출했고, 모델링 결과 유입하수, 무산소조에 유입시킬 경우 방류수 수질이 가장 적게 상승하는 것을 확인할 수 있었다. 이와 같은 결과를 바탕으로 연계처리수의 유입 유량을 유입하수와 무산소조로 분배하여 유입시킬 경우에 대하여 분배 비율에 대한 다양한 시나리오를 생성했다. 다양한 시나리오를 통해 모델링을 진행한 결과 유입하수(80%), 무산소조(20%)의 비율로 연계처리수의 유입유량을 분배 유입 시킬 경우 TN, TP의 수질이 가장 적게 상승하는 것으로 나타났다.

고분자전해질 연료전지 구동 중 수소투과도 측정 (Measurement of Hydrogen Crossover During PEMFC Operation)

  • 정재진;정재현;김세훈;안병기;고재준;박권필
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.412-416
    • /
    • 2015
  • 고분자 막 성능 평가 및 내구성 평가에 이용하기 위해 고분자전해질 연료전지(PEMFC) 구동 중에 수소 크로스오버 측정이 필요하다. 수소 크로스오버 측정 시에 불활성 기체 대신에 공기를 cathode에 공급하면서 기체 크로마토그래프로 수소 농도를 cathode 출구에서 분석하였다. PEMFC 구동 중 고분자 막을 통과한 수소는 cathode에서 산소와 반응해 불활성 가스를 공급할 때에 비해 수소 농도가 감소하였다. cathode 공기 공급 유량이 증가하면 수소 농도가 감소했고, 셀의 온도와 습도, 압력이 증가하면 cathode의 수소 농도는 증가했다. 일반적인 PEMFC 구동 조건에서 $120mA/cm^2$ 전류밀도에서 수소농도는 약 5.0 ppm이었다.

유기물 절연 박막에 대한 유전상수의 변화에 대한 연구 (Study on the Variation of Dielectronic Constant for an Organic Insulator Film)

  • 오데레사
    • 한국진공학회지
    • /
    • 제17권4호
    • /
    • pp.341-345
    • /
    • 2008
  • SiOC 박막을 산소와 bistrimethylsilylmethane 전구체의 유량비를 다르게 하여 플라즈마 발생 화학적 기상 증착방법으로 증착하였다. 증착된 SiOC박막은 Fourier transform infrared spectroscopy에 의해서 분석하였으며, 알킬기에 의한 $1000\;cm^{-1}$ 근처에 나타나는 Si-O-C 결합의 형성되는 모양과 유전상수와의 상관성에 대하여 살펴보았다. 열처리 유전상수는 더욱 낮아졌고, BTMSM/$O_2$의 유량비가 증가함에 따라서 유전상수의 선형적인 상관성은 없었다. 구간별로 유전상수는 증가했다가 감소하는 경향성이 반복적으로 나타났으며, 유전상수와의 상관성은 FTIR 스펙트라 분석기에 의해서 $950{\sim}1200\;cm^{-1}$ 에서 나타나는 Si-O-C 결합모드에서 찾을 수 있었다. Si-O-C 결합모양이 넓게 퍼지는 화학적 이동이 관찰되는 곳에서 유전상수는 낮아졌으며, 이러한 화학적 이동이 일어나는 샘플에서 유전상수가 1.65로 조사되었다.

강유전체 박막 커패시터 하부전극에 관한 연구 (A Study on Bottom E1ectrode for Ferroelectric Thin Film Capacitors)

  • 임동건;정세민;최유신;김도영;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.364-368
    • /
    • 1997
  • We have investigated Pt and RuO$_2$as a bottom electrode for a device application of PZT thin film. The bottom electrodes were prepared by using an RF magnetron sputtering method. We studied some of the property influencing factors such as substrate temperature, gas flow rate, and RF power. An oxygen partial pressure from 0 to 50% was investigated. The results show that only Ru metal was grown without supp1ying any O$_2$gas. Both Ru and RuO$_2$phases were formed for O$_2$partial pressure between 10∼40%. A Pure RuO$_2$ phase was obtained with O$_2$partial pressure of 50%. A substrate temperature from room temperature to 400$^{\circ}C$ was investigated with XRD for the film crystallinity examination. The substrate temperature influenced the surface morphology and the resistivity of Pt and RuO$_2$as well as the film crystal structure. From the various considerations, we recommend the substrate temperature of 300$^{\circ}C$ for the bottom electrode growth. Because PZT film growth on top of bottom electrode requires a temperature process higher than 500$^{\circ}C$, bottom electrode properties were investigated as a function of post anneal temperature. As post anneal temperature was increased, the resistivity of Pt and RuO$_2$was decreased. However, almost no change was observed in resistivity for an anneal temperature higher than 700$^{\circ}C$. From the studies on resistivity and surface morphology, we recommend a post anneal temperature less than 600$^{\circ}C$.

  • PDF