• Title/Summary/Keyword: Oxygen flow rate

Search Result 689, Processing Time 0.034 seconds

Computational Simulation by One-Dimensional Regeneration Model of Wall-Flow Monolith Diesel Particulate Filter Trap (벽-유동(Wall-Flow) 모노리스(Monolith) 디젤 입자상물질 필터 트랩의 재생모델에 의한 수치 시뮬레이션)

  • Kim, G.H.;Park, J.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.41-54
    • /
    • 1995
  • A mathematical model for wall-flow monolith ceramic diesel particulate filter was developed in order to describe the processes which take place in the filter during regeneration. The major output of the model comprises ceramic wall temperature and regeneration time(soot reduction). Various numerical tests were performed to demonstrate how the gas oxygen concentration, flow rate and the initial particulate trap loading affect the regeneration time and peak trap temperature. The model is shown to b in reasonable agreement with the published experimental results. This model can be applied to predict the thermal shock failure due to high temperature during combustion regeneration process.

  • PDF

The study on low dielectric thin film deposition using DEMS precursor by PECVD (DEMS(Diethoxymethylsilane) precursor를 이용한 PECVD 저유전물질 박막증착연구)

  • Kang, Min-Goo;Kim, Dae-Hee;Kim, Yeong-Cheol;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.4
    • /
    • pp.35-39
    • /
    • 2008
  • We studied deposition of low-k SiOCH dielectric film by PECVD. DEMS(diethoxymethlysilane) precursor, which has two ethoxy groups along with one methyl group attached to the silicon atoms, was used as precursor. The SiOCH film was deposited as a function of oxygen flow rates ranging from 0 to 100sccm. The deposition rate($\AA$/min) of SiOCH film was increased due to the increase of oxygen radical as a function of $O_2$ flow rates. The dielectric constant was decreased from 3.0 to 2.77, as the film was annealed at $450^{\circ}C$ for 30 min. So, it could account that the dielectric constant changes sensitively with $O_2$ flow rates. Also, the leakage current of the annealed film exhibited stable curve than that of asdeposited. These results were caused by the increase of Si-O-Si group and decrease of Si-CH group and OH group within the film by annealing.

  • PDF

Potentiometric NOx sensors for automotive exhaust using YSZ(yittria stabilized zirconia) electrolyte (YSZ 전해질을 이용한 농담전지식 자동차용 NOx센서)

  • Park, Jin-Su;Park, Kwang-Chol;Park, C.O.
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.434-440
    • /
    • 2007
  • Two kinds of new NOx sensing mechanism was proposed and examined. One of those was potentiomtric sensor based on the measurement of decomposed oxygen from NO using YSZ porous diffusion barrier and Pd catalytic electrode. The sensor based on decomposed oxygen measurement responded to the range of 300 - 1000 ppm NO in $N_{2}$ environment and the sensitivities were coincident with theoretical values at 700 and $800^{\circ}C$ but the decomposition rate depended on gas flow rate. The other sensor was equilibrium potentiometric type using $Gd_{2}O_{3}$-nitrates solid solution as sensing material. The sensor using $Gd_{2}O_{3}$-nitrates solid solution was suitable for NOxxsensing at $700^{\circ}C$ in 5 % oxygen and the sensitivity was 19.3 mV/decade. However, long term stability of the sensing material at high temperature was not sufficient.

Hydrodynamics and parametric study of an activated sludge process using residence time distribution technique

  • Sarkar, Metali;Sangal, Vikas K.;Bhunia, Haripada
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.400-408
    • /
    • 2020
  • Hydrodynamic study of Activated Sludge Process (ASP) is important to optimize the reactor performance and detect anomalies in the system. Residence time distribution (RTD) study has been performed using LiCl as tracer on a pilot scale aeration tank (AT) and ASP, treating the pulp and paper mill effluent. The hydraulic performance and treatment efficiency of the AT and ASP at different operating parameters like residence time, recycle rate was investigated. Flow anomalies were identified and based on the experimental data empirical models was suggested to interpret the hydrodynamics of the reactors using compartment modelling technique. The analysis of the RTD curves and the compartment models indicated increase in back-mixing ratio as the mean hydraulic retention time (MHRT) of the tank was increased. Bypassing stream was observed at lower MHRT. The fraction of dead zone in the tank increased by approximate 20-25% with increase in recycle rate. The fraction of the stagnant zone was found well below 5% for all performed experiments, which was under experimental error. The substrate removal of 91% for Chemical oxygen demand and 96% for Biochemical oxygen demand were observed for the ASP working at a hydraulic mean residence time 39 h MRT with a 20% recycling of activated sludge.

Corrosion Behavior of Hastelloy C-276 for Carbon-anode-based Oxide Reduction Applications

  • Jeon, Min Ku;Kim, Sung-Wook;Choi, Eun-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.383-393
    • /
    • 2020
  • The corrosion behavior of Hastelloy C-276 was investigated to identify its applicability for carbon-anode-based oxide reduction (OR), in which Cl2 and O2 are simultaneously evolved at the anode. Under a 30 mL·min-1 Cl2 + 170 mL·min-1 Ar flow, the corrosion rate was less than 1 g·m-2·h-1 up to 500℃, whereas the rate increased exponentially from 500 to 700℃. The effects of the Cl2-O2 composition on the corrosion rate at flow rates of 30 mL·min-1 Cl2, 20 mL·min-1 Cl2 + 10 mL·min-1 O2, and 10 mL·min-1 Cl2 + 20 mL·min-1 O2 with a constant 170 mL·min-1 Ar flow rate at 600℃ was analyzed. Based on the data from an 8 h reaction, the fastest corrosion rate was observed for the 20 mL·min-1 Cl2 + 10 mL·min-1 O2 case, followed by 30 mL·min-1 Cl2 and 10 mL·min-1 Cl2 + 20 mL·min-1 O2. The effects of the chlorine flow rate on the corrosion rate were negligible within the 5-30 mL·min-1 range. A surface morphology analysis revealed the formation of vertical scratches in specimens that reacted under the Cl2-O2 mixed gas condition.

Development of Personal Compact Oxygen Generator using Vacuum Swing Absorption (개인용 VSA방식 소형 산소발생기 개발)

  • Jang, Jun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2479-2483
    • /
    • 2012
  • This paper discusses the development of a personal compact oxygen generator for portable and mobility. The compact oxygen generator is operated with vacuum swing absorption by compact vacuum pump. The components of oxygen generator is composed on the miniaturization and weight reduction, and it is optimized by discharge pump speed, nozzle diameter and 3-way valve interval. In 0.5mm of nozzle diameter, $O_2$ concentration is approximately 37%, and flow rate is $1{\ell}$/min. On the 30cm away from the nozzle, $O_2$ concentration is increased approximately 0.5%.

Properties of Al-doped ZnO Transparent Conducting Oxide Films Deposited with Ar Flow Rate by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 증착된 Al 도핑된 ZnO 투명 전도 산화막의 Ar 유량에 따른 특성)

  • Yi, I.H.;Kim, D.K.;Kim, H.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.206-210
    • /
    • 2010
  • Al-doped ZnO thin films were deposited with various Ar flow rate by RF magnetron sputtering, and theire properties were studied. A high-quality thin film was obtained by controlling the Ar flow rate, and the influence of the Ar flow rate on the Al-doped ZnO thin film was confirmed. In all Al-doped ZnO thin films, light transmittance had above 80%. Through Hall measurement and X-ray photoelectron spectrometer, the sample of 60 sccm, which had the lowest resistivity, showed the lower Al concentration. This result was attributed to oxygen vacancy rather than Al concentration.

A Study on the Deposition Condition for Stoichimetric $\textrm{Ta}_2\textrm{O}_5$ Thin Films by DC Magnetron Reactive Sputtering Technique (DC Magnetron 반응성 스퍼터링 방법을 이용한 stoichiometric $\textrm{Ta}_2\textrm{O}_5$막의 증착조건에 관한 연구)

  • Jo, Seong-Dong;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.551-555
    • /
    • 1999
  • The deposition condition to obtain stoichiometric $Ta_2$O\ulcorner films, which is still controversial, using magnetron reactive sputtering was studied. The films were deposited by varying $O_2$gas flow rate with sputtering power and Ar gas flow rate of 200W and 60 sccm fixed. At the conditions of $O_2$ gas flow rate over 20 sccm, amorphous Tantalum oxide films with the refractive index of 2.1 and dielectric constant of 25 were deposited. Among those films, the capacitors dielectric properties of the film deposited at the condition of $O_2$ gas flow rate 50 sccm was best, the leakage current was 1$\times$10\ulcornerA/$\textrm{cm}^2$ at the electric field strength of 0.5 MC/cm and the breakdown field strength was over 2.0 MV/cm. This result could be explained from the analysis comparing with a standard sample using RBS because the composition of the film deposited at this condition was closest to the stoichiometric $Ta_2$O\ulcorner. The result of XPS analysis convinced that this film was stoichiometric $Ta_2$O\ulcorner film. A maximum cathode voltage was observed when $O_2$gas flow rate was 30 sccm. This shows that the Schiller's proposition that one can obtain stoichiometric films at the condition of maximum cathode voltage is not correct and more oxygen than that of the maximum voltage condition is necessary to deposit the stoichiometric Ta$_2$O\ulcorner films.

  • PDF

A Study on the Flow Rate Performance of Plunger-Type High-Pressure Pump for Compression Ignition Engine Using DME as Fuel (DME를 연료로 하는 압축 착화 엔진 용 플런저식 고압펌프의 유량 성능 연구)

  • Jeong, Jaehee;Lee, Sejun;Yu, Donggyu;Lim, Ocktaeck
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.1-8
    • /
    • 2022
  • DME, a clean fuel that is being studied as an alternative fuel for diesel engines, can reduce exhaust gas, which is the one of the crucial problems of diesel engines, and has a very high cetane number and high oxygen content. DME is a fuel has properties similar with LPG and can use the infrastructure of LPG. In this study, The target was to build a database of basic data on the mass flow rate discharged for the performance evaluation of the plunger-type high pressure pump. In this study, the mass flow rate of the DME plunger type high pressure pump was analyzed by changing the common rail pressure and the motor rotation speed. The experimental conditions were the common rail pressure was changed from 300 to 500 bar and the motor rotation speed was changed from 300 to 1000 rpm. In addition, basic mass flow data were constructed to high-pressure pumps for DME. As a result of the experiment, in both cases the mass flow rate was increased.

Analysis of ROX Index, ROX-HR Index, and SpO2/FIO2 Ratio in Patients Who Received High-Flow Nasal Cannula Oxygen Therapy in Pediatric Intensive Care Unit (고유량 비강 캐뉼라 산소요법을 받은 소아중환자실 환아의 ROX Index와 ROX-HR Index 및 SpO2/FIO2 Ratio분석)

  • Choi, Sun Hee;Kim, Dong Yeon;Song, Byung Yun;Yoo, Yang Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.53 no.4
    • /
    • pp.468-479
    • /
    • 2023
  • Purpose: This study aimed to evaluate the use of the respiratory rate oxygenation (ROX) index, ROX-heart rate (ROX-HR) index, and saturation of percutaneous oxygen/fraction of inspired oxygen ratio (SF ratio) to predict weaning from high-flow nasal cannula (HFNC) in patients with respiratory distress in a pediatric intensive care unit. Methods: A total of 107 children admitted to the pediatric intensive care unit were enrolled in the study between January 1, 2017, and December 31, 2021. Data on clinical and personal information, ROX index, ROX-HR index, and SF ratio were collected from nursing records. The data were analyzed using an independent t-test, χ2 test, Mann-Whitney U test, and area under the curve (AUC). Results: Seventy-five (70.1%) patients were successfully weaned from HFNC, while 32 (29.9%) failed. Considering specificity and sensitivity, the optimal cut off points for predicting treatment success and failure of HFNC oxygen therapy were 6.88 and 10.16 (ROX index), 5.23 and 8.61 (ROX-HR index), and 198.75 and 353.15 (SF ratio), respectively. The measurement of time showed that the most significant AUC was 1 hour before HFNC interruption. Conclusion: The ROX index, ROX-HR index, and SF ratio appear to be promising tools for the early prediction of treatment success or failure in patients initiated on HFNC for acute hypoxemic respiratory failure. Nurses caring for critically ill pediatric patients should closely observe and periodically check their breathing patterns. It is important to continuously monitor three indexes to ensure that ventilation assistance therapy is started at the right time.