• Title/Summary/Keyword: Oxygen Permeable Membrane

Search Result 15, Processing Time 0.017 seconds

Study of Polysulfone Membrane for Membrane-covered Oxygen Probe System (산소 전극 시스템에 사용되는 polysulfone막에 대한 연구)

  • Hong, Suk In;Kim, Hyun Joon;Park, Hee Young;Kim, Tae Jin;Jeong, Yong Seob
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.877-887
    • /
    • 1996
  • The ideal membranes for membrane-covered oxygen probes system should be selectively permeable for oxygen and chemically inert, and have good mechanical strength. Polysulfone(PSf) was selected to develop the membrane for membrane-covered oxygen electrodes system. PSf membranes have properties such as good reproducibility, good mechanical strength, chemical inertness, and high heat resistance. PSf membranes were cast from polymer solution on the glass plate at constant temperature, and casting solvents used were tetrahydrofuran(THF), methylene chloride, and N-methyl-2-pyrrolidone(NMP). Tricresyl phosphate(TCP) as plasicizer was added to PSf to increase the softness of membrane. The permeation characteristics were observed for pure oxygen and nitrogen through pure PSf membranes by variable volume method and membrane-covered electrode system. The permeability coefficients of oxygen and nitrogen measured by variable volume method were slightly decreased with increasing of upstream pressure. The permeation properties of PSf membrane using methylene choride as casting solvent were not affected by the PSf amount of polymer solution. The permeability coefficients of oxygen and nitrogen for PSf membrane containing TCP were very slightly lower than those for pure PSf membrane, but ideal separation factors were slightly higher. The flexibility of PSf membrane containing 2wt% TCP was better than that of pure PSf membrane. It was expected that this increase in flexibility would solve the difficulty of fixing the membrane to the cathode. The membrane-covered oxygen probes system was composed of anode, cathode and electrolyte. The type of the anode was Ag/AgCl half-cell, that of cathode was Ag, and the electrolyte was 4N KCl solution. The result of sampled current voltametry for PSf membrane showed the plateu region at -0.3V~-1.0V. The correlation coefficient of oxygen partial pressure versus current for PSf membrane was relatively high, 0.99949. It was concluded that PSf membrane was the good candidate for the membrane-covered oxygen probes system.

  • PDF

Oxygen Permeation and Syngas Production of La0.7Sr0.3Ga0.6Fe0.4O Oxygen Permeable Membrane (La0.7Sr0.3Ga0.6Fe0.4O 분리막의 산소투과특성 및 합성가스의 생성)

  • 이시우;이승영;이기성;정경원;김도경;우상국
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.594-600
    • /
    • 2003
  • L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ perovskite-type mixed conducting membranes, which could permeate oxygen selectively, have been fabricated and the microstructural features developed by varying the sintering conditions have been analyzed. The effects of surface modification and the membrane thickness on oxygen permeability have been evaluated under He/air environment. With increasing a grain boundary fraction, the overall oxygen permeability decreased. The syngas (CO+ $H_2$) has been produced by partial oxidation reaction of methane with the oxygen permeated through the membrane. Methane conversion and syngas yield have been evaluated as functions of the compositional ratio of feed gas and reaction temperature. In long-term duration test for 600 h, under C $H_4$+He/air environment, L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane showed a highly stable performance.

Oxygen Permeation and Mechanical Properties of La0.6Sr0.4Co0.2Fe0.8O3-δ Membrane with Different Microstructures (미세구조에 따른 La0.6Sr0.4Co0.2Fe0.8O3-δ 분리막의 산소투과 및 기계적 특성)

  • Lee, Shi-Woo;Lee, Seung-Young;Lee, Kee-Sung;Woo, Sang-Kuk;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.994-1000
    • /
    • 2002
  • Oxygen permeability and the mechanical properties of mixed ionic-electronic conductive $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ perovskite-type membrane, fabricated by solid state reaction, were investigated with regard to microstructure. The microstructure of the membrane was controlled by changing the sintering temperature and holding time. The average grain size and relative density were evaluated as a function of sintering conditions. As the fraction of grain boundary decreased, oxygen permeability showed a tendency to increase. Especially the maximum oxygen flux of 0.37 ml/$cm^2$${\cdot}$min was measured for the specimen sintered at 1300${\circ}C$ for 10 h, which has high density and relatively large grain size. Fracture strength was dependent on the relative density of sintered body, while fracture toughness increased with average grain size.

Control of Molecular Weight, Stereochemistry and Higher Order Structure of Siloxane-containing Polymers and Their Functional Design

  • Yusuke Kawakami;Yuning Li;Yang Liu;Makoto Seino;Chitsakon Pakjamsai;Motoi Oishi;Cho, Yeong-Bee;Ichiro Imae
    • Macromolecular Research
    • /
    • v.12 no.2
    • /
    • pp.156-171
    • /
    • 2004
  • We describe the precision synthesis schemes of siloxane-containing polymers, i.e., the control of their molecular weight, stereoregularity, and higher-order structures. First, we found a new catalytic dehydrocoupling reaction of water with bis(dimethylsilyl)benzene to give poly(phenylene-disiloxane). Together with this reaction, we applied hetero-condensations to the synthesis of thermally stable poly(arylene-siloxane)s. The dehydrocoupling reaction was applied to the synthesis of syndiotactic poly(methylphenylsiloxane) and poly(silsesquioxane)s, which we also prepared by hydrolysis and deaminative condensation reactions. We discuss the tendency for loop formation to occur in the synthesis of poly(silsesquioxane) by hydrolysis, and provide comments on the design of functionality of the polymers produced. By taking advantage of the low energy barrier to rotation in the silicon-oxygen bond, we designed selective oxygen-permeable membrane materials and liquid crystalline materials. The low surface free energy of siloxane-containing systems allows surface modification of a blend film and the design of holographic grating materials.

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF