A Disturbance Observer Design for Compensating Backlash at Robot Joint (로봇 관절의 백래쉬 보상을 위한 외란관측기 설계)

  • Ahn, Won-Ki;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.187-189
    • /
    • 2006
  • In mechanical system, gear trains have backlash innately. With the presence of inherent backlash, the overall system performance is limited in many practical control systems. It has been reported that a disturbance observer has the property of effective removing disturbance and cutting measurement noise off. The plant is remodeled with modified disturbance observer to observe and compensate backlash characteristics. And this paper describes a method to design Q filter and to analyze the effects of disturbance and measurement noise to the output. It is shown that the vibration and tracking error caused by backlash were decreased and the time constant and relative degree are important factor to design Q filter.

  • PDF

Development and Analysis of Fuzzy Overall Equipment Effectiveness (OEE) in TPM (TPM에서 퍼지 OEE 모형의 개발 및 분석)

  • Choi, Sungwoon
    • Journal of the Korea Management Engineers Society
    • /
    • v.23 no.4
    • /
    • pp.87-103
    • /
    • 2018
  • This paper introduces the method to develop two main types of the fuzzy OEE (Overall Equipment Effectiveness) models via triangular membership function for measuring uncertainty. The fuzzy OEE includes model type 1 and model type 2. The model type 1 is used when the theoretical machine speed only reflects the time loss whereas model type 2 is used when the actual machine speed reflects both time and speed loss. Model type 2 has shown to perform a lower availability rate and a higher performance rate compared to model type 1. In addition, the fuzzy UPH (Unit Per Hour) which is derived from using the fuzzy OEE is presented to satisfy demand uncertainty. The fuzzy UPH can easily measure the fuzzy tact time and cycle time by reciprocating itself. Finally, this study demonstrates the fuzzy OEE models using IVIFS (Interval-Valued Intuitionistic Fuzzy Set) based on the characterization via membership function, non-membership function and hesitant function. For the purpose of analyzing the fuzzy system OEE, the OEE for each machine of plant structure is considered triangular interval-valued intuitionistic fuzzy number. Regardless of plant structure, the validity degree of fuzzy membership function of system OEE decreases when the number of machine with worst value of the validity degree increases. Corresponding examples are presented in this paper for practitioner to understand the applicability and practicability of the proposed fuzzy OEE methods.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

A study of the ISCS(Information Security Check Service) on performance measurement model and analysis method (정보보호 안전진단 성과관리 측정 모델 및 성과 분석 방안 연구)

  • Jang, Sang-Soo;Shin, Seung-Ho;Noh, Bong-Nam
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.127-146
    • /
    • 2010
  • This report has continuously improved in Information Security Level of Information Communication Service Companies which are applicable to Information Security Safety Inspection System. Also, it presents a decided methodology after verified propriety and considered the pre-research or expropriation by being developed the way of Information Security Safety Result Measurement. Management territory weighted value was established and it was given according to the point of view and the strategy target and the and outcome index to consider overall to a measurement item. Accordingly, an outome to the Information Security Check Service is analyzed by this paper and measurement model and oucome analysis methodology are shown with this, and gives help to analyze an outcome. Also it make sure the the substantial information security check service will be accomplished, prevent a maintenance accident beforehand and improve an enterprise outcome independently by institutional system performance securement and enterprise.g corporate performance.

Quality Assurance for High Dose Rate Brachytherapy (고선량율 근접치료의 정도관리)

  • Bang, Dong-Wan;Cho, Chung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

Performance Measurement Framework for Efficient Virtualization System Profiling (효율적인 가상화 시스템 프로파일링을 위한 성능측정 프레임워크)

  • Jang, Eun-Tae;Choi, Sang-Hoon;Park, Ki-Woong
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.3
    • /
    • pp.31-39
    • /
    • 2019
  • Virtualization technology is one of the technologies that have been attracting attention as cloud computing spreads recently. When a system is constructed using virtualization technology, mutiple operation systems can be operated in a single host operating system, thereby facilitating efficient management of computing resources. As more and more operating systems are running on the hypervisor, it is important to measure the overall performance of the virtualization system and this is becoming an important technology. In this paper, we analyze the main functions of the existing profiling tools to measure the performance of the virtualization system, and measure and classify the profiling coverage that the monitoring tools can perform for events that may occur in the virtualization system. In addition, we have studied a framework that enables performance measurement by loading appropriate profiling tools into the guest system when performance measurement is required for the virtualization system according to the information received from the remote system performing the monitoring.

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

The Strain Analysis by Noncontact Measurement Method in the Steel Plate Welded Zone of Automobile (비접촉 계측법에 의한 자동차 판금용접부의 스트레인 해석)

  • Kim, In-Ju;Park, Chang-Eon;Sung, Baek-Sub;Heo, Up
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1521-1524
    • /
    • 2003
  • Currently the plates used for the various structures has a tendency to being slim to the degree of the sheet metal vis-a-vis the overall measurements of the structure, and the conditions of their usage and load have been getting diverse. As the structure material has been used more and more under the various conditions, the necessity of the strength analysis is to be required. While most of these methods are simply based on the strain gaging method; that is, directly attaching most of the material to the gage, using the non-contact method is still in the early stage. One of the non-contact methods is by the use of the laser that has high-level of the accuracy for the measurement, and this laser also has excellent characteristics on which many studies for its applications are focused throughout the many fields. Therefore, this dissertation is on the measurement of the strain caused by the characteristics of the TIG welded zone which is used with 3D ESPI system that is functionally modified through the laser ESPI system.

  • PDF

A Methodology for Performance Modeling and Prediction of Large-Scale Cluster Servers (대규모 클러스터 서버의 성능 모델링 및 예측 방법론)

  • Jang, Hye-Churn;Jin, Hyun-Wook;Kim, Hag-Young
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1041-1045
    • /
    • 2010
  • Clusters can provide scalable and flexible architectures for parallel computing servers and data centers. Their performance prediction has been a very challenging issue. Existing performance measurement methodologies are able to measure the performance of servers already constructed. Thus they cannot provide a way to predict the overall system performance in advance when designing the system at the initial phase or adding more nodes for more capacity. Therefore, the performance modeling and prediction methodology for large-scale clusters is highly required. In this paper, we suggest a methodology to predict the performance of large-scale clusters, which consists of measurement, modeling and prediction steps. We apply the methodology to a real cluster server and show its usefulness.

Design and Lithographic Fabrication of Elliptical Zone Plate Array with High Fill Factor

  • Anh, Nguyen Nu Hoang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • An elliptical zone plate (EZP) array is important in off-axis optical systems because it provides two advantages. First, the residual beam and the main source are not focused in the same direction and second, the light from the observation plane is not reflected back towards the beam source. However, the fill factor of the previous EZP array was about 76% which was a little low. Hence, this EZP array could not collect the maximum amount of illumination light, which affected the overall optical performance of the lens array. In this study, we propose a new EZP array design with a 97.5% fill factor used in off-axis imaging system for enhancement of brightness and contrast. Then, direct laser lithography was used to fabricate the high fill factor EZP array by moving the XY linear stage of the system in a zigzag motion. The imaging properties of the proposed EZP array were experimentally verified at the focal plane and compared with the previous model.