• Title/Summary/Keyword: Overall measurement system

Search Result 381, Processing Time 0.027 seconds

Measurement of Imaging Property of Flat-Panel Detector

  • Matsumoto, Masao;Suekane, Kouji;Maeda, Kouji;Ogata, Yuji;Inamura, Kiyonari;Kanai, Kouzo;Kanamori, Hitoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.385-388
    • /
    • 2002
  • We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curves, Modulation Transfer Function (MTF), Wiener spectra (WS), Noise Equivalent Quanta (NEQ) and Detective Quantum Efficiency (DQE)) for the direct type and indirect type of Flat-Panel Detector (FPD). First, the digital and overall characteristic curves of the both types of FPD had more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of the direct-type FPD were superior to those of the indirect-type FPD. Third, for identical exposures, the digital and overall WS of the direct-type FPD were similar or worse than those of the indirect-type FPD, and for larger exposure, the digital WS of the both types of FPD were smaller, but overall WS of the both types of FPD were larger. Fourth, the digital and overall NEQ and DQE of the direct-type FPD were worse than both NEQ and DQE of the indirect-type FPD at lower spatial frequencies, but were better at higher spatial frequencies.

  • PDF

Anti-amnesic Effect and Antioxidant Defense Systems of Yukmijihwang-tang on Scopolamine-induced Memory Impairment in Mice (Scopolamine 유발 건망증 마우스 모델에서 육미지황탕(六味地黃湯)의 기억력 개선 및 항산화 효과)

  • Seo, Young-Min;Han, Da-young;Kim, Sang-ho;Chung, Dae-kyoo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.29 no.4
    • /
    • pp.207-221
    • /
    • 2018
  • Objectives: The objective of this study was to observe the anti-amnesic effects of Yukmijihwang-tang (YMJHT), on the scopolamine (Sco)-induced memory impairment in C57BL/6 mice through its favorable acetylcholine (ACh). Also, to observe acetylcholinesterase (AChE) activity, Choline acetyltransferase (ChAT) mRNA expressions, and antioxidant effect. Methods: Six groups, with a total of 20 normal and 100 Sco treated mice were selected based on their body weights after 1 week of acclimatization, were used in this study as follows. Half of the mice in each group were used for passive avoidance task tests and hippocampus ACh content, AChE activity and ChAT mRNA expression measurement, and the remaining half in each group used for Morris water maze test and measurement of cerebral antioxidant defense system. Results: Amnesia due to AChE activations and destroyed cerebral cortex antioxidant defense systems were markedly and dose-dependently inhibited after 28 days of continuous oral pre-treatment with YMJHT 400, 200 and 100 mg/kg, respectively. The overall effects of YMJHT 400 mg/kg were similar to those of tacrine 10 mg/kg. Conclusions: Based on the results, it was established that oral administration of YMJHT favorably alleviates Sco-induced memory impairment, through preservation of ACh, mediated by up-regulation of ChAT mRNA expressions and related AChE inhibition and augmentation of cerebral antioxidant defense system, at least in a condition of this experiment. The overall effects of YMJHT 400 mg/kg were similar to those of tacrine 10 mg/kg.

Evaluation of Dynamic Behavior of Rail Joints on Personal Rapid Transit Track (소형무인경전철(PRT)궤도 레일이음매의 동적거동 분석)

  • Choi, Jung-Youl;Kim, Jun-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.89-94
    • /
    • 2016
  • The objective of this study was to estimate the dynamic behavior of a personal rapid transit(PRT) track system using a rail of rectangular tube section and a rail joint of sliding type, and to compare the results with the normal rail and rail joint of a PRT track system by performing field measurements using actual vehicles running along the service lines. The measured vertical displacement of rail and sleeper, and vertical acceleration of rail for the normal rail and rail joint section were found to be similar, and the rail joint of sliding type satisfied the design specifications of the track impact factor for a conventional railway track. The experimental results showed that the overall dynamic response of the rail joint were found to be similar to or less than that of the normal rail, therefore the rail joint of sliding type for PRT track system was sufficient to ensure a stability and safety of PRT track system.

A Study on Performance Risk Measurement for the Defense R&D Program (국방연구개발사업 수행위험 측정방안 연구)

  • Choi, Myung-Jin;Na, Ho-Young;Lee, Sang-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.309-316
    • /
    • 2009
  • The risk management is a method to identify and to handle risk factors. In this paper, we introduce a methodology that can be used to measure of system's performance risk by combining system's TPM(technical performance measures) in the R&D(research and development) program for defense acquisition. By applying the suggested procedure, we can monitor risk trends in R&D program by calculation of system's overall TPM and find out where management should target to reduce or remove the system's performance risk.

Feasibility Study of Fine Dust Removal Technology in Construction Site (건설현장 미세먼지 제거기술의 타당성 분석)

  • Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.120-121
    • /
    • 2019
  • The construction industry is known to be one of the representative industries that generate fine dust. Therefore, reducing the amount of fine dust generated in construction sites is very important for the overall fine dust management. Based on this, this study proposed the concept of fine dust measurement and removal technology combined with advanced technologies such as drones and IoT. The qualitative, quantitative and risk elimination effects that can be expected when applying the proposed technique are analyzed. We will verify the effectiveness of the proposed concept through system development and field application, and evaluate specific economic feasibility through cost analysis. The proposed concept will be validated through system development and field application and evaluated specific economics through cost analysis.

  • PDF

Effects of Shading on the Growth and Chlorophyll Fluorescence under Agrivoltaic System Conditions

  • Hoejeong Jeong;Myeong-Gue Choi;Woon-Ha Hwang
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.120-120
    • /
    • 2022
  • Agrivoltaic System (AVS) was introduced with the concept that it could generate electricity by using the extra light remain after crops use for photosynthesis in farm, which can earn additional income. However, crop yield was declined under the AVS condition due to the decrease in light energy. In the past, many researchers have been studied about crop states under shading conditions. However, the phenomenon of partial shading such as under the AVS is not well studied. In this study, to figure out the response of crop under the different light conditions, the electron transport rate (ETR) and non-photochemical quenching (NPQ) of rice was investigated using the chlorophyll fluorescence measurement. Also, physiological changes of crops under the shading conditions were investigated. The growth experiment under partial shading under AVS and overall shading which made of 35% shade cloth was conducted to understand the eco-physiological responses of rice to light in terms of the photosynthesis. Under the shading conditions, SPAD value and chlorophyll contents were higher, but the leaf thickness was lower than control. The overall shading condition show lower ETR than others during the growing season. In contrast, NPQ was higher than other treatments. This means the available light energy cannot contribute to photosynthesis under the shading condition.

  • PDF

Gas Temperature Measurement in Supersonic Flows by N2+ Emission Spectroscopy (질소 이온 발광 분광법을 이용한 초음속 유동의 기체 온도 측정)

  • Shin, Ji-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • The procedure for estimating the gas (rotational) temperature of an air discharge in supersonic flows is presented in detail. Since direct measurement of the temperature in a supersonic flow is difficult, a nonintrusive measurement was performed by optical emission spectroscopy based on the emission spectra of nitrogen molecular ions. A detailed explanation, including the equations for emission line intensity, is presented in order to understand the structure of the emission spectra of nitrogen molecular ions. Using the obtained representation for emission spectrum, a synthetic spectrum of the first negative system of $N_2^+$ is obtained, and it is compared with the experimentally measured spectrum. Within a relative error of approximately 6.8% for the overall band spectra, the synthetic and measured spectra agree well. In the case of a 25-mA DC air discharge in a supersonic (Mach 3) flow, the gas temperature profile shows an approximately linear variation and a peak temperature of approximately 350 K.

A Study on MZ Generation(2030s) Male Body Shape Comparison and Body Shape Change - Focused on the 7th and 8th Size Korea's Anthropometric Data - (MZ세대(2030대) 남성의 체형비교 및 체형 변화 연구 - 제 7차, 제 8차 사이즈코리아 직접 측정치를 기준으로 -)

  • Ji-Eun Kim;Eun-Kyong Kim
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.1
    • /
    • pp.33-47
    • /
    • 2023
  • In this study, the difference in human body dimensions between the age groups of Generation M (27 to 39 years old) and Generation Z (20 to 26 years old) was analyzed. This study also analyzed if there was a change in the body shape of the MZ generation, who have different sensibilities from the "young people" of the past. In addition, major changes in human body dimensions were carefully analyzed and presented as basic data for clothing design. Therefore, a t-test was performed to verify the significant differences in the measurements of each age group. To examine the change in human body measurements according to the measurement year, the 7th and 8th size Korea data statistics were analyzed. The main required dimensions of clothing design were analyzed graphically for visual changes according to measurement year and age group. As a result of the analysis, Generation Z was found to have a difference in body shape from Generation M, and is generally smaller and slimmer with broader shoulders. In addition, the body shape change between the 7th and 8th measurement periods was significantly higher than the 8th measurement overall. Height has increased and back length has become shorter, resulting in a larger ratio of lower body length. In addition, the proportion of obesity abnormalities has increased. Therefore, since the dimensional system set from the past data can cause problems for the fitting of clothing for the MZ generation, it is necessary to design the clothing and reset the dimensional system making it suitable for the changed the body shape of the MZ generation.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

Measurement of the Three-Dimensional Flow Fields of a Gun-Type Gas Burner Using Triple Hot-Wire Probe (3중 열선 프로브를 이용한 Gun식 가스버너의 3차원 유동장 측정)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.23-31
    • /
    • 2006
  • Mean velocities and turbulent characteristics in the three-dimensional flow fields of a gun-type gas burner were measured by using triple hot-wire probe (T-probe) in order to compare them with the results already presented by X-type hot-wire probe (X-probe). Vectors obtained by the measurement of two kinds of probes in the horizontal plane and in the cross section respectively show more or less difference in magnitude each other, but comparatively similar shape in overall distribution. Axial mean velocity component along the centerline shows that the value by T-probe is about ten times smaller than that by X-probe above the range of X/R=3. Also, the axial component of turbulent intensity along the centerline appears the biggest difference between the two probes. Moreover, axial mean velocity component, axial turbulent intensity component and rotational along the Y-directional distance show a big difference between slits and swirl vanes. On the whole, the values by T-probe appear smaller than those by X-probe.

  • PDF