• Title/Summary/Keyword: Over Load

검색결과 2,144건 처리시간 0.023초

3차원 벡터유한요소법을 이용한 도파관 정합부하의 최적형상설계 (Optimal Shape Design of Waveguide Matched Load Using 3 Dimensional Vector Finite Element Method)

  • 김준오;이흥배;천창률;한송엽;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1213-1215
    • /
    • 1994
  • The shape of lossy material inside a waveguide matched load is optimally designed to give low reflection over a given frequency range. The 3 dimensional vector finite element mettled is used as an analysis tool which does not generate spurious mode. The optimizing process used in this parer is the Powell technique. The designed load gives the low reflection about -30 dB around 10GHz with 1.5 wavelength of the load length.

  • PDF

궤도 승용차 시스템의 적용 검토 (Study on the Application of Personal Rapid Transit System)

  • 최재혁
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.31-38
    • /
    • 1998
  • Guideway Transportation will provide the break-through to solve the traffic problems, which a lot of big cities have over the world. APM (Automated People Mover) system, Guideway Transportation, is classified by PRT, GRT, and MRT according to the capacity of passenger to be carried by its system. In the Application of PRT (Personal Rapid Transit) system, the enact analysis of the traffic problem on the area to be applied should be preceded. PRT system is characterized by Off-Line and Demand Operation. The Network of PRT system depends on the Load Time and Load Pattern. The operation of PRT system will have move efficient way when it is applied to the network with evenly distributed Load Time and Load Pattern.

  • PDF

전력계통 주파수의 최적분산제어에 관한 연구 (Optimal and decentralized control of power system frequency)

  • 박영문;이승재;서보혁
    • 전기의세계
    • /
    • 제29권10호
    • /
    • pp.667-677
    • /
    • 1980
  • A new approach for optimal decentralized load-frequency control in a multi-area interconnected power system is presented, which includes the optimal determination of decentralized load-frequency controller, observer for unmeasurable local states and load disturbances, quadratic estimator for tie-line power flow information transmitted at intervals. The optimal design of the decentralized controller is based on a modified application of the singular perturbation theory, and the decentralized Luenberger obeserver uses techniques of state augmentation for exponential disturbance functions and the representation of tie-line power flow states as non-directly-controlled inputs. The approach presented herein is numerically tested through Elgerd's two-area load-frequency system model, and the results demonstrate remarkable advantages over the conventional ones.

  • PDF

비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계 (A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads)

  • 이우철;이택기
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

3상 10kVA 고온초전도 변압기의 특성 (Characteristics of a 10kVA three phase superconducting power transformer)

  • 이승욱;이희준;차귀수;이지광;류경우;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.24-26
    • /
    • 2001
  • The high temperature super-conductor transformer gains interests from the industries. This paper described construction and test results of a 10kVA HTS transformer. Three phase transformer with double pancake windings were constructed. BSCCO-2223 wire, silicon sheet steel core and FRP cryostats were used in that transformer After the test of basic properties of the 3 phase HTS transformer using no load test, short ciucuit test and full load test, continuous operation of 100 hours with pure resistive load has been carried out. Test proved over-load capability and reliability of the HTS transformer.

  • PDF

Design Method and Analysis for Current Limit Charger of Battery System for Regulating CDE Power of Satellite

  • Kim, Kyudong
    • 항공우주시스템공학회지
    • /
    • 제14권6호
    • /
    • pp.74-78
    • /
    • 2020
  • The cooler driver electronics (CDE) for maintaining a low temperature of a satellite payload IR sensor has a compressor with a pulsation current load when in operation. This pulsation current creates a large voltage fluctuation and may negatively affect both the load and regulated bus stability. Thus, a CDE power conditioning system has a battery for use as a buffer that is connected in front of the CDE load line. In this system, a battery charger limiter circuit is required to protect from an over-charge of the battery and power to the load. In this study, an optimal design and parameter selection were developed and simulated.

차량 구조물 안전설계를 위한 진동특성에 관한 연구 (A Study on the Vibration Characteristics for Safety Design of Vehicle Structure)

  • 신귀수;이기형
    • 한국안전학회지
    • /
    • 제13권2호
    • /
    • pp.13-21
    • /
    • 1998
  • This is a study on the natural vibration characteristics of Vehicle frame. Nowadays, many trucks freight the over-load, do the car designers consider the over-load about 200% in the design. It's necessary to make the model of a vehicle and simulate it for the test of driving condition, durability and vibration behavior before the vehicle is manufactured. If it is possible to make a simulation using the static and dynamic analysis, this is very useful in accomplishing an optimal design of the vehicle. In this paper, we studied the vibration characteristics of a truck body frame. The automobile body frame model for experiment is made smaller than real size frame with the ratio of 1/10. The vibration characteristics of a frame is considered as one of main factors in analyzing and improving the problem for ride comfort, noise and vibration reduction. Therefore, we experimented two method to neglect the nonlinearity. First is bolting and second is welding at the joint section. We compared computer simulation results and experimental data.

  • PDF

A Computational Study on the Unsteady Lateral Loads in a Rocket Nozzle

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.289-292
    • /
    • 2008
  • Highly over-expanded nozzle of the rocket engines will be excited by non-axial forces due to flow separation at sea level operations. Since rocket engines are designed to produce axial thrust to power the vehicle, non-axial static and/or dynamic forces are not desirable. Several engine failures were attributed to the side loads. Present work investigate the unsteady flow in an over-expanded rocket nozzle in order to estimate side load during a shutdown/starting. Numerical computations has been carried out with density based solver on multi-block structured grid. Present solver is explicit in time and unsteady time step is calculated using dual time step approach. AUSMDV is considered as a numerical scheme for the flux calculations. One equation Spalart-Allmaras turbulence model is selected. Results presented here is for two nozzle pressure ratio i.e. 100 and 20. At 100 NPR, restricted shock separation (RSS) pattern is observed while, 20 NPR shows free shock separation (FSS) pattern. Side load is observed during the transition of separation pattern at different NPR.

  • PDF

지속하중 재하시 보강토 옹벽의 거동특성 - 축소모형실험 (Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading)

  • 유충식;김선빈;변요셉;김영훈;한대희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.121-130
    • /
    • 2006
  • Despite a number of advantages of reinforced earth walls over conventional concrete retaining walls, there exit concerns over long-term residual deformation when used as part of permanent structures. In view of these concerns, time-dependant deformation characteristics of geosynthetic reinforced modular block walls under sustained loads were investigated using reduced-scale model tests. The results indicated that a sustained load can yield appreciable magnitude of residual deformation, and that the magnitude of residual deformation depends on the loading characteristic as well as reinforcement stiffness.

  • PDF

SCR 에 의한 직류회로차단기의 과부하차단특성개선 (A Study on DC Circuit Breaker using SCR Chung Hoo Park)

  • 박정후
    • 수산해양기술연구
    • /
    • 제14권2호
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF