• Title/Summary/Keyword: Output indicator

Search Result 113, Processing Time 0.033 seconds

Daily check device manufacture and efficiency Evaluation for daily Q.A (일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가)

  • Kim Chan Yong;Je Yeong Wan;Lee Je Hui;Park Heung Deuk
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • Introduction: Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Methods and Materials: Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment, field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Result: We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}\;2\%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}\;1mm$. Conclusion: We can enforce output measurement and appliances check conveniently and time was reduced and was able to raise efficiency of business. We were able to bring n cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

Monetary Policy Transmission during Multiple Indicator Regime: A Case of India

  • SETHI, Madhvi;BABY, Saina;DAR, Vandita
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.3
    • /
    • pp.103-113
    • /
    • 2019
  • The effectiveness of monetary policy critically depends upon how well the transmission mechanism functions, so that the desired impact on output and inflation is achieved. The purpose of this paper is to study the transmission mechanism of monetary policy by analyzing the impact on inflation and output during multiple indicator regime (1998-99 to 2014) in an emerging economy-India. The Inflation Targeting Regime is also briefly outlined alongwith the impact on output and inflation. Using quarterly data for the period 1997 to 2017, the paper uses weighted average call money market rate as a proxy for the policy rate and evaluates the strength of the interest rate channel. We use a conventional Structural vector auto regression (SVAR) methodology to evaluate the efficacy and show the impluse response functions. Our results find that changes in the policy rate impact output growth steeply with a lag of about two quarters and the impact on inflation is maximized after three quarters. The study concludes that the monetary policy in India has a significant impact on output and inflation in the short-to-medium-run. After the policy shock, the fall in the output growth rate is of greater magnitude than the fall in inflation.

A Fast Lock and Low Jitter Phase Locked Loop with Locking Status Indicator (Locking 상태 표시기를 이용한 저잡음 고속 위상고정 루프)

  • Choi Young-Shig;Han Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.582-586
    • /
    • 2005
  • This paper presents a new structure of Phase Locked Loop(PLL) which changes its loop bandwidth according to the locking status. The proposed PLL consists of a conventional PLL and, Locking Status Indicator(LSI). The LSI decides the operating bandwidth of loop filler. When the PLL becomes out of lock, the PLL increases the loop bandwidth and achieves fast locking. When the PLL becomes in-lock, this PLL decreases the loop bandwidth and minimizes phase noise output. The PLL can achieve fast locking and low phase noise output at the same time. Proposed PLL's locking time is less than $40{\mu}s$ and spur is 76.1dBc. It is simulated by HSPICE in a Hynix CMOS $0.35{\mu}m$ Process.

New accuracy indicator to quantify the true and false modes for eigensystem realization algorithm

  • Wang, Shuqing;Liu, Fushun
    • Structural Engineering and Mechanics
    • /
    • v.34 no.5
    • /
    • pp.625-634
    • /
    • 2010
  • The objective of this paper is to apply a new proposed accuracy indicator to quantify the true and false modes for Eigensystem Realization Algorithm using output-based responses. First, a discrete mass-spring system and a simply supported continuous beam were modelled using finite element method. Then responses are simulated under random excitation. Natural Excitation Technique using only response measurements is applied to compute the impulse responses. Eigensystem Realization Algorithm is employed to identify the modal parameters on the simulated responses. A new accuracy indicator, Normalized Occurrence Number-NON, is developed to quantitatively partition the realized modes into true and false modes so that the false portions can be disregarded. Numerical simulation demonstrates that the new accuracy indicator can determine the true system modes accurately.

Estimation of Engine Output for Marine Diesel Engines (선박용 디젤엔진의 출력산정에 관한 연구)

  • Jung, Kyun-Sik;Lee, Jin-Uk;Jung, Jin-Ah;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.436-442
    • /
    • 2011
  • To obtain the engine output correctly is basically very important factor for estimating a engine performance. But, it has been reported that the IHP measured from electronic indicator such as MIPS(Mean Indication Pressure System) has a deviation compared to mechanical indicator. It was reported by authors that the uncertainty of crank angle for TDC position could be one of the reasons. In this paper, the uncertainty of crank angle for TDC position and its influence to engine output were investigated respectively about M/E and G/E for marine diesel engines. For the purpose, two sampling methods of pressure in cylinder were considered which were 'angle base sampling' and 'time base sampling'. Angle base sampling is real crank angle acquired from angle encoder which is attached to crank shaft and time base sampling is crank angle calculated by detected revolution with Z-pluse of encoder. Time base sampling is same method of MIPS. This paper concluded that time base sampling method is not suitable for obtaining the output of marine diesel engine on board because of instantaneous speed variation and load fluctuation. Also it is verified that the variation of engine speed by load fluctuation should be one of reasons additionally in case of M/E.

Development of Energy Efficiency Indicator in the Steel Industry (철강산업의 에너지효율 지수개발과 관리기법 연구)

  • Lee, Sang-Youp;Ahn, Yoon-Gih
    • Environmental and Resource Economics Review
    • /
    • v.12 no.1
    • /
    • pp.29-48
    • /
    • 2003
  • The Steel Industry has made a significant contribution to the increase of energy use in Korea. This paper presents a method for development energy efficiency indicator in the steel industry based on the decomposing approach. This paper develops a logically consistent method for decomposing a change in energy consumption into the effects of three factors structural change, energy intensity and output level. Numerical illustration of the method is given using 1992~2001 data for energy consumption in a virtual works. The most dominant factor is revealed to be the output effect. The energy intensity for the steel industry has increased and the effect of such a growth was relatively strongly reflected in the decomposition analysis. The structural effect turned out to be also important during the periods.

  • PDF

The Value of Mixed Venous Oxygen Saturation during and after Cardiopulmonary Bypass (체외순환중의 중심 정맥 산소포화도의 의의)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.7-10
    • /
    • 1995
  • Mixed Venous oxygenation saturation[SvO2 is a variable determined in part by the externally controlled factors and in part by the patient during CPB. I monitored the SvO2 and tested it as a parameter for the regulation of pump output and as a criteria for the need of inotropics after CPB. With the help of SvO2, I increased the pump flow especially during rewarming for more optimal oxygenation of cells. After CPB, the calculated cardiac index was used as an indicator for the need of inotropic support with greater accuracy and without any clinical problems. I conclude that the SvO2 is an easily checkable variable and a good indicator for optimal oxygenation at cell level, and can be used as an objective criteria for the need of postoperative inotropic support.

  • PDF

New Indicators of Global Integration Using Input-Output Analysis

  • DONGSEOK KIM
    • KDI Journal of Economic Policy
    • /
    • v.46 no.2
    • /
    • pp.45-74
    • /
    • 2024
  • The import content of export (ICE) has served as an indicator of global integration for several decades. It is defined as the share of imported products embodied in exports and can be interpreted as the relative degree of the utilization of global production network (GPN) over the domestic supply chain (DSC) in terms of 'value-added.' This paper proposes two new indicators of global integration. They are defined as the ratios of imports (foreign products) to gross output (domestic products) generated by exports and can be interpreted as the relative degrees of the utilization of GPN over DSC in terms of 'production.' Both indicators are easy to compute and can be compared between years, between countries, between industries, and between groups of industries. The paper applies the new indicators to the recent edition of the OECD's Input-Output Database. Finally, the paper shows that the recent slowdown in international trade is mostly due to the decrease in the international trade of intermediate goods, with significant implications regarding the future of global integration.

Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A (일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가)

  • Kim Chan-Yong;Jae Young-Wan;Park Heung-Deuk;Lee Jae-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Purpose : Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Materials and Methods : Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Results : We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}2%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}1mm$. Conclusion : We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF