• Title/Summary/Keyword: Output Ripple Current

Search Result 334, Processing Time 0.024 seconds

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF

A High-Efficiency High Step-Up Interleaved Converter with a Voltage Multiplier for Electric Vehicle Power Management Applications

  • Tseng, Kuo-Ching;Chen, Chun-Tse;Cheng, Chun-An
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.414-424
    • /
    • 2016
  • This paper proposes a novel high-efficiency high-step-up interleaved converter with a voltage multiplier, which is suitable for electric vehicle power management applications. The proposed interleaved converter is capable of achieving high step-up conversion by employing a voltage-multiplier circuit. The proposed converter lowers the input-current ripple, which can extend the input source's lifetime, and reduces the voltage stress on the main switches. Hence, large voltage spikes across the main switches are alleviated and the efficiency is improved. Finally, a prototype circuit with an input voltage of 24 V, an output voltage of 380 V, and an output rated power of 1 kW is implemented and tested to demonstrate the functionality of the proposed converter. Moreover, satisfying experimental results are obtained and discussed in this paper. The measured full-load efficiency is 95.2%, and the highest measured efficiency of the proposed converter is 96.3%.

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Characteristic analysis of the current type high frequency resonant DC - DC converter (전류형 고주파 공진 DC-DC 컨버터의 특성해석)

  • 황계호;남승식;김동희;심광열;안항목
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.86-93
    • /
    • 2003
  • This paper describes that the resonant tank type DC-DC converter consist of reactor and capacitor resonant tank circuit for increased the output current. This circuit configuration is composed of the resonant tank circuit used resonant capacitor and reactor and the capacitor connected in switch are a common using by resonance capacitor and ZVS(Zero Voltage Switching) capacitor. Therefore, the proposed converter can reduce a switching losses, noise, and voltage stress at turn-on and turn-on and has an advantage which is able to operating safely in load short, because DC reactor is connected with resonance reactor in order to supply a fixed current with low ripple from DC power supply. The analysis of proposed circuit uses normalized parameters and characteristic estimation is generally described the proposed circuit with the characteristics of power and output voltage etc. Also, design is based on the characteristic estmations in each step. Hence, We conform a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment.

A Study on LCL Filter Design and EMTP-RV Simulation for Grid-connected Three Phase Inverter (계통 연계 3상 인버터를 위한 LCL 필터 설계 및 EMTP-RV 시뮬레이션 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.261-270
    • /
    • 2021
  • In this study, the design methodology of LCL filter for grid-connected three-phase inverter was studied. First, the advantages and disadvantages of applying typical filter structures as a filter for grid connection of a three-phase inverter were analyzed. Next, filter design methodologies for grid connection of a three-phase inverter were analyzed, and an effective filter design methodology was determined to satisfy the harmonic requirements in grid connection. In order to verify the effectiveness of the design methodology, EMTP models such as a three-phase inverter, a three-phase LCL filter, and a performance evaluation system to evaluate the performance of the designed filter were developed using EMTP-RV. Next, an LCL filter was designed for an application example of a three-phase inverter, and the waveforms of the output voltage and outage current of the three-phase inverter were checked through EMTP-RV simulation work. In particular, the validity of the design methodology was verified by confirming that the magnitude of the current ripple was reduced to a limited magnitude through waveform analysis of the output current.

The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage (불평형 전압으로 운전시 비선형 부하에 나타나는 현상)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

Influence on the PFC circuit with characteristics variation of MPP core (금속분말 코어의 특성변화가 PFC 회로에 미치는 영향)

  • Ju J.K.;Ahn T.Y.;Jang P.W;Jeong I.B.;Choi G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.434-438
    • /
    • 2003
  • This paper present an investigation of the influence on the PFC(power factor correction) circuit with characteristics variation of MPP (Molybdenum permalloy powder) core. The experiment results of the 1.5kW class Boost converter for PFC rectifier with the average current mode control are evaluated to verify the influence on the PFC converter with inductance variation of the MPP core. As a results, it is shown that the ripple of the inductor using a MPP core increase with output power of the converter.

  • PDF

Vector Controlled Inverter for Elevator Drive (ELEVATOR 구동용 VECTOR 제어 인버터)

  • Shin, H.J.;Jang, S.Y.;Lee, S.J.;Lee, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.627-630
    • /
    • 1991
  • This study is about vector controlled inverter for high quality elevator drive that is to improve the settling accuracy of elevator car and passenger's comfort in commercial buildings. In this study, an instantaneous space vector control type inverter was used to reduce the torque ripple ant to improve the velocity follow-up. This method calculates Instantaneous actual output torque and flux of induction motor by voltage and current, then compares them with a reference values by a speed regulator. The outputs of comparators select a switching mode, for an optimal voltage vector. Also, this study used IGBT (Insulated Gate Bipolar-Transistor), a high speed switching element, to reduce sound noise level, and DSP (Digital Signal Processor) was used to improve the reliability of the control circuit by fully digitalization.

  • PDF

THREE PHASE PWM AC-DC BOOST CONVERTER WITH UNITY POWER FACTOR (단위 역률로 동작하는 3상 PWM AC-DC BOOST콘버어터에 관한 연구)

  • Chun, Chang-Gun;Park, Sung-Jun;Kwon, Soon-Jae;Kim, Chul-U
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.397-399
    • /
    • 1994
  • In this parer, the development of input power factor and the harmonic distortion of line current were showed in the proposed three phase AC-DC converter. We identified that DC voltage in the output terminal has fast dynamic response and has nearly ripple. Moreover, the converter also possesses the regenerative capability which is useful for many applications. The switching frequency of this converter operated with constant in the range of 2KHZ. Finally, simulation and experiment results are presented.

  • PDF