• Title/Summary/Keyword: Output Module

Search Result 1,023, Processing Time 0.028 seconds

The RELAY Module Design of Multi SNS Channel Auto Streaming Server (다중 SNS 채널 자동 스트리밍 서버의 RELAY 모듈 설계)

  • Ahn, Heuihak;Lee, Daesik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • Streaming server is that an image produced in real time or a file form of image produced ahead consists of SNS service, and the relay module of streaming server includes output management module that set an output channel more than 2 and control transmission of video content. This thesis intends to suggest how to stream through plural output channel that contains output channel of external streaming server using relay module and do streaming provided to terminal receiving image, and streaming server, streaming system for this. Thus, by extending output channel sending out image to output channel of external streaming server, the scale of streaming server is not limited and the process allotting external streaming server into output channel sending the image becomes simple, so management of output channel becomes efficient even when sending several images.

Development of Decoding Program Module for PLC Output Expansion (PLC출력 확장 디코딩 프로그램 모듈 개발)

  • You, Jeong-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.131-133
    • /
    • 2005
  • In this paper, we proposed the program module that expand output points when increased of the output machine for the design of process control system with PLC. In order to incense output points we need the decoding. There is a hardware decoding and a software decoding. In this paper, we proposed the decoding program module which is a software decoding and confirmed feasibility through a simulation.

  • PDF

A Study on Architecture Design of Output Module for SIL4 Safety Related System (SIL4 안전관련 시스템에 적합한 출력 모듈의 구조 설계에 대한 연구)

  • Yoo, Deung-Ryeol;Hwang, Kyeng-Hwan;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.10
    • /
    • pp.1079-1086
    • /
    • 2015
  • This paper introduces the architecture of OUTPUT module that is suitable using in safety related system having SIL4 and proposes the quantitative target that is required for OUTPUT module. Especially, only output type that is made up Relay output signal and analog signal among various output ways is applied in output module that is a part of safety related system. The FMEA(Failure Modes and Effect Analysis), FTA(Fault Tree Analysis) are used as analysis method. As a result, it proposes to the architecture and failure frequency of the Output module that is used in SIL4 safety related system.

Power Performance Characteristics of Transparent Thin-film BIPV Module depending on an Installation Angle (건물일체형 태양광발전시스템(BIPV)의 설치조건에 따른 발전특성 연구)

  • An, Young-Sub;Song, Jong-Hwa;Kim, Seok-Ge;Lee, Sung-Jin;Yoon, Jong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.386-389
    • /
    • 2008
  • This study has analysed power output characteristics of transparent thin-film PV module depending on incidence angle and azimuth. The simulation results was evaluated power outputs of transparent thin-film PV module depending on incidence angle and azimuth after calibrating the experimental and computed data. As a result, the best power output performance of transparent thin-film PV module was obtained at slope of $30^{\circ}$ to the south, producing the annual power output of 977kWh/kWp. The annual power output data demonstrated that the PV module with a slope of $30^{\circ}$ could produce a 68 % higher power output than that with a slope of $90^{\circ}$, with respect to the inclined slope of the module. Furthermore, the PV module facing south showed a 22 % higher power output than that facing to the east in terms of the angle of the azimuth.

  • PDF

The Electrical Characteristics of PV Module by the Stress in accordance with Mechanical Weight Load (기계적 하중에 따른 스트레스로 인한 PV 모듈의 전기적 특성)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.104-109
    • /
    • 2009
  • If the Photovoltaic(PV) Module should get physical load, the PV module will be warped according to elongation of the front glass and then micro-crack will be occurred in the heat sealed Solar Cell. This micro-crack drops output of the short circuit current and the open circuit voltage of the PV Module. This is because of increase of resistance component by micro-crack. Micro-crack at specific Solar Cell in the module reduces the durability of PV Module such as less output, Hot-Spot in the PV module caused by Solar Cell output mismatch, heat generating as resistance component caused by micro-crack. In this study, among some factors which effect to the output of crystalline PV Module, we will see how the micro-crack caused by mechanical stress effects to the electrical output of PV Module.

  • PDF

A Study on the Analysis of the Output Characteristics of the Floating Photovoltaic System (수상태양광발전시스템의 출력 특성 분석에 관한 연구)

  • Choi, Won Yong;Lee, Jae-Hyeong;Choa, Sung-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.5
    • /
    • pp.312-317
    • /
    • 2017
  • In this paper, the effects of environmental variables on the output of the floating photovoltaic water systems, which were installed at the Hapcheon dam in South Korea, were investigated, and the correlations between them were analyzed. The system output was linearly proportional to the solar radiation or irradiance. The output was large in spring and autumn because of high irradiance, but low in the summer when the solar module temperature was high. The influence of the module temperature on the system output was limited in the summer, during which the module temperature change affected the system output more than the change of the irradiance did. In addition, in winter and summer, the module temperature tended to decrease with increasing windspeed, but windspeed did not affect module temperature significantly in the spring and autumn. On the other hand, in winter and spring, the irradiance decreased as the windspeed increased because of movement (or circulation) of the photovoltaic modules.

Analysis of Soiling for the Installation Direction of PV Module (태양전지 모듈의 설치방향에 따른 오염특성 분석)

  • Lee, Chung Geun;Shin, Woo Gyun;Lim, Jong Rok;Ju, Young Chul;Hwang, Hye Mi;Ko, Suk Whan;Chang, Hyo Sik;Kang, Gi Hwan
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.76-82
    • /
    • 2020
  • Soiling on the surface of a PV module reduces the amount of light reaching the solar cells, decreasing power performance. The performance of the PV module is generally restored after contaminants on the module surface are washed away by rain, but it accumulates at the bottom of the module owing to the thickness of the module frame, causing an output mismatch on the PV module. Since PV modules are usually installed horizontally or vertically outdoors, soiling can occur at the bottom of the PV module, depending on the installation direction due to external environmental factors. This paper is analyzed the output characteristics of a PV module considering its installation direction and the soiling area. The soiling was simulated to use transparent films with 5% transmittance, and the transmission film was attached to the bottom part of the PV module horizontally and vertically. When the soiling area was 33% of the string at the bottom of the PV module, the power output decreased similarly regardless of installation direction. However, when the soiling area was 66% of the string at the bottom of the PV module, it was confirmed that the output performance decreased sharply when installed vertically rather than horizontally.

Implementation and Test of RELAY Module for Multiple SNS Channels (다중 SNS 채널을 위한 RELAY 모듈의 구현 및 실험)

  • Ahn, Heui-Hak;Lee, Dae-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.362-369
    • /
    • 2018
  • In this paper, we propose a procedure to multiple SNS channels automatic streaming through multiple output channels including the output channel of an external streaming server. The multiple SNS channels automatic streaming server includes an output management module for controlling the transmission of video contents to RELAY module that establish two or more output channels. In this paper, we experimented by separate with HD and FHD video using RELAY module in multiple SNS channel automatic streaming. In stream modules using RELAY module of HD video, when the publisher client and the player client and the RELAY module are 1 channel, the occupancy rate of CPU is 0.6% and the occupancy rate of heap memory is 0.3%(20 Mbyte). When the publisher client and the player client and the RELAY module are 183 channels, the occupancy rate of CPU is 99.9% and the occupancy rate of heap memory is 45.8%(3.7Gbyte). Therefore, the paper is not limited to the size of the streaming server by extending the output channel from which the video is transmitted to the output channel of the external streaming server. And a process of allocating an output channel of an external streaming server to an output channel through which an video is transmitted can be easily performed, so that an efficient output channel management can be performed even when a plurality of videos are transmitted.

Power Performance Characteristics of Transparent Thin-film BIPV Module depending on an installation angle (건물일체형 투광성 PV모듈의 설치각도별 발전특성에 관한 연구)

  • Song, Jong-Hwa;Yoon, Jong-Ho;An, Young-Sub;Kim, Seok-Ge;Lee, Sung-Jin;Choung, Youn-Kyoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.58-63
    • /
    • 2008
  • This study has analysed power output characteristics of transparent thin-film PV module depending on incidence angle and azimuth. The experiment results showed power outputs of transparent thin-film PV module applied to full-scale mock up model on slope of $90^{\circ},\;30^{\circ},\;0^{\circ}$ to the south. The simulation results was evaluated power outputs of transparent thin-film PV module depending on incidence angle and azimuth after calibrating the experimental and computed data. As a result. the best power output performance of transparent thin-film PV module was obtained at slope of $30^{\circ}$ to the south, producing the annual power output of 977kWh/kWp. The annual power output data demonstrated that the PV module with a slope of $30^{\circ}$ could produce a 68 % higher power output than that with a slope of $90^{\circ}$ with respect to the inclined slope of the module, Furthermore, the PV module facing south showed a 22 % higher power output than that facing to the east in terms of the angle of the azimuth, Specipically. the varying power output with incidence angle of PV module can be resulted from the influence of incidence angle modifier of glass on PV module. That is, the solar energy transmission can be reduced as an increase of incidence angle of PV module. Therefore, when the inclined slope of the PV module was over $70^{\circ}$ there was a significant reduction of power output, and this was caused by the decrease of solar energy transmission in the transparent thin-film PV module.

System of Culture Satellite Account (문화위성계정 체계)

  • Kim, Ji-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.6
    • /
    • pp.879-889
    • /
    • 2010
  • In this paper I summarize the compiling method of culture satellite account which has been recommended by international statistic organizations, and I suggest the required statistics which is need to compile Korean culture satellite account. Culture satellite account is recommended to be composed of five modules and each module has to has its specific function respectively. The first module is macro-information module, the second module is quantity/volume output module, the third module is characterization module, the fourth module is targeted analysis/analytical module, and the fifth module is documentation module. Each module is recommended to contain cultural demand and supply statistics of respective module from the first module to the fourth module.