• 제목/요약/키워드: Outdoor insulator

검색결과 102건 처리시간 0.024초

Effect of Silicone-modified Microsilica Content on Electrical and Mechanical Properties of Cycloaliphatic Epoxy/Microsilica System

  • Park, Jae-Jun;Yoon, Chan-Young;Lee, Jae-Young;Cheong, Jong-Hoon;Kang, Geun-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.155-158
    • /
    • 2016
  • The effect of microsilica content modified with silicone-modified epoxy on electrical and mechanical properties of cycloaliphatic epoxy/microsilica system was investigated. The cycloaliphatic epoxy resin was diglycidyl 1,2-cyclohexanedicarboxylate and curing agent was an anhydride. Surface of microsilica was modified with silicone-modified epoxy. Electrical breakdown strength, the most important property for electrical insulation materials was tested. Tensile and flexural tests were also performed using universal testing machine (UTM). The microcomposite with 60 wt% microsilica shows maximum values in electrical breakdown strength.

EPDM 및 실리콘 재질의 폴리머현수애자의 특성 비교 (The Comparison of EPDM and Silicone in Housing Materials of Polymeric Suspension Insulators)

  • 이병성;이재봉;송일근;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.6-10
    • /
    • 2003
  • In our country, the housing materials of polymeric outdoor insulators have mainly been used EPDM or silicone rubber. EPDM housing materials had been widely used in the field for the first time. The reason why silicone has the high cost of production. But recently, most of the manufacturers that newly developed polymeric insulators make its choice of silicone housing. EPDM showed a good resistance to tracking. We compared the various characteristics for EPDM and silicone insulators that have similar type and design. Silicone insulators have more performance in flashover voltage test and leakage current measurement because of a good water repellent than EPDM ones. Also, the property of EPDM compared with silicone insulators greatly decreased after aging test in combined acceleration ageing facilities for 1000 hours.

  • PDF

Effect of Surface Charge in Hydrophobicity of Insulating Material and Decay of Surface Voltage after Corona Charging

  • Huh, Chang-Su;Youn, Bok-Hee;Seo, You-Jin;Hwang, Sun-Mook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.1-5
    • /
    • 2003
  • This paper presented the effects of accumulation of surface charges on hydrophobicity level and the surface states of silicone polymer used for outdoor insulator treated by ultraviolet irradiation and corona discharge through measuring surface voltage decay of a corona-charged specimen were investigated. The surface resistivity by the method of the surface potential decay was compared with the value by the three electrodes methods. From this study, it was found that the accumulation of surface charges above a critical surface voltage on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addtion, uv stress lead to a longer decay time of surface charges. We could conclude that the effects of surface charges on hydrophocity level and the changes of surface state by various artificial treatments were understood through a trend of surface potential decay.

  • PDF

옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석 (The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door)

  • 문중섭;서광석;김정호;이재형;송우창;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

자외선 열화에 의한 실리콘고무의 열화 특성 연구를 위한 열화장치 및 시험방법의 개발 (Development of Aging Equipment and Testing Method for UV Effected Degradation Characteristics of Silicone Rubber)

  • 이정헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.93-96
    • /
    • 2007
  • In this paper, the testing equipment for evaluating aging characteristics of outdoor silicone rubber insulator resulting from the environmental aging effect with regards to sunlight(UV) was developed. Influence of sunlight effect aging is seriously increase due to destruction of ozone layer which is occurred by consumption of fossil fuel. For this purpose, silicone rubber was aged under the artificial sunlight by exposure of xenon lamp radiation in the accelerating aging chamber and various test and analysis were performed such as breakdown strength, contact angle. And FT-IR analysis has been followed.

  • PDF

RTV 실리콘 고무 코팅재의 표면전하 축적이 발수성에 미치는 영향 (Effect of Accumulated charges on Surface Hydrophobicity of RTV Silicone Rubber)

  • 연복희;허창수;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In this paper, we evaluated the effect of accumulated charges on hydrophobicity of room temperature vulcanized(RTV) silicone rubber, which could improve the contamination performance of porcelain insulators, with uv radiation time. Outdoor insulating material could be charged by the corona discharge on field intensified area of insulator and discharge between the water drops. In addition, we performed the accelerated uv radiation on samples and investigated the change of charging decay with time. In this results, it is found that silica-like structure on the surface of RTV silicone rubber was formed by uv treatments and this layer have the characteristic of retaining the charges on surface for a long time. These charges have effects on its hydrophobicity and so adversely effects on contamination performance. Based on our results, we discussed the other degradation mechanism with well known ones.

  • PDF

주위 환경 변화 따른 폴리머 절연재료의 표면 누설전류 (The Study of Leakage Current Distributions of Plymeric Insulators will Changing Environment)

  • 이병성;한재홍;김주용;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.88-91
    • /
    • 2001
  • Our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate leakage current patterns caused by surface aging on polymeric insulators, we utilized the combined aging test facility and leakage current monitoring system. And we get the continuous leakage current values from each sample. After completing the 3000h combined aging cycle test, leakage current measurement were conducted for these samples and carried out harmonics analysis for its data.

  • PDF

가교시간에 따른 고분자 재료의 트래킹성과 자외선 열화특성 (Tracking Resistance and UV Degradation Property of Polymeric Insulating Materials by Cross-Link Time)

  • 천종욱;이운용;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.447-450
    • /
    • 2002
  • Recently polymeric insulators and arresters are being used for outdoor high voltage applications. Polymeric insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymeric insulator kind are a relatively new technology, but their expected life is still unknown. In this paper, the material property for polymeric insulating material such as silicone rubber and EPBM is investigated by cross-link time and the relation between tracking resistance and W resistance is analyzed by IEC 60587 and W aging experiment.

  • PDF

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

EPDM의 초기 및 열화특성에 관한 연구 (A Study on the Aging and Initial Characteristics of EPDM)

  • 임장섭;한재홍;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.217-220
    • /
    • 2001
  • Fractal mathematics is being highlighted as a research method for classification of image. But the application of Fractal dimension(FD) has been required the complicated calculation method because of its complex repetition progressing. In this paper, it has been applied the new approach method to express FD for aging level calculation and investigated the relative degradation processing in outdoor EPDM insulator. As a result after testing, new proposed method has a capability to estimate in case of the field operated EPDM and accelerating test. Therefore, we find the differency of operated EPDM according to field condition.

  • PDF