• Title/Summary/Keyword: Out of roundness measurement

Search Result 12, Processing Time 0.02 seconds

A Study on the out-diameter measuring machine by the LVDT sensors (LVDT 센서를 이용한 외경 측정 방안에 대한 연구)

  • Hwang J.H.;Roh J.H.;Park Ki-Hong
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF

A Study on the Measurement of Roundness Profile for Rotating Object Using Two Points in Succession Measuring Method (축차 2점법을 이용한 회전체의 진원도 프로파일 측정에 관한 연구)

  • Lee, Min-Ki;Lee, Eung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1029-1034
    • /
    • 2010
  • In this paper, we present the roundness profile and run-out error measurement for a rotating shaft. The devices for measuring the roundness require a precision rotation table which is used as a reference to obtain the circular profile. Therefore, the roundness measuring system is expensive and requires precision manufacturing. The two-point method for succession measurement has been used to obtain a linear profile or used in straightness measurement using two displacement measuring devices. In this paper, the method is used for measuring the circular profile of a rotating shaft. A method to remove the vibration of the shaft, i.e., the run-out, is used, and the original circular profile is obtained from the measured raw data that excludes the run-out error of the rotating shaft. This method will be useful for obtaining the precise circular profile without using a precision reference circular artifact.

A Study on the Measurement and Evaluation of LSC Roundness by Index Head (INDEX HEAD를 이용한 절대 진원도의 측정 평가에 관한 연구)

  • Lee, Dong-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.3
    • /
    • pp.18-26
    • /
    • 1991
  • A study on the measuring and evaluation of LSC(Least Square Center) roundness was carried out. The experimental set-up was made by index head and indicator, and the measuring data were compensated by a developed computer program. The results obtained are as follows : 1) An index head can conveniently be used to measure LSC roundness. 2) A program for calculating LSC roundness is developed. 3) Without a high quality roundnes measuring apparatus, LSC roundness can be measured and calculated by using index head and the developed program in machine shop as well as in a measuring room

  • PDF

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.

An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method- (眞圓度 測定器의 誤差特性에 대한 解析 -위상차법-)

  • 한응교;허문석;박익근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

A Study on the Development of Pistion Measuring System (피스톤 측정 시스템 개발에 관한 연구)

  • 김경석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.2
    • /
    • pp.19-25
    • /
    • 1997
  • The purpose of this study is the development of professional measuring system of piston. Designed values are compared with values of measured data of oval shape piston and allowable range and deviation are printed out by using this system. Thereafter, it is able to measure ovality precisely and to estimate its quality rapidly.

  • PDF

Monitoring of Grinding Force in Plunge Grinding Process (원통 플런지 연삭시 연삭력에 관한 실험적연구)

  • Park, Jong-Chan;Park, Cheol-Woo;Lee, Sang-Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.881-894
    • /
    • 1999
  • Cylindrical plunge grinding is widely used for final machining process of precision parts such as automobile, aircraft, measurement units. But in order to make parts which have high precision accuracy and high surface integrity, it is necessary to consider grinding characteristics due to accumulation phenomena of grinding wheel in plunge grinding process. In this study, in order to examine closely plunge grinding process, grinding power, grinding force, real depth of cut are monitored in transient state, steady state and spark out state. As the result, it is shown that grinding power and force are affected by dressing condition, depth of cut and speed ratio and that there exist threshold grinding force and it also affected by dressing condition. Also considered effects of grinding conditions on surface roughness and roundness of workpiece

Measurement of Radial Error Motions of a Rotating Spindle by Moire Topography (모아레 원리를 이용한 스핀들의 반경방향 회전정도 측정)

  • 박윤창;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2723-2729
    • /
    • 1993
  • Moire principles are applied to the measurement of the spindle radial error motion. As opposed to conventional techniques, no master cylinder or ball is needed in the measurement so that the offset and out-of-roundness errors of the master can be inherently eliminated. Two periodic circular gratings are used, one is made on the spindle and the other is held stationary on the reference frame. When the two gratings are seen superimposed during spindle rotation, an interference fringe pattern is observed from which the information on the eccentricity between the two gratings can be extracted with high precision. The optical design and fringe analysis techniques of a prototype measurement system are described in detail with exemplary measurement results.

Development of the Measuring System of the Rotational Accuracy of main Spindles (주축의 회전정도 측정시스템의 개발)

  • Sin, Yeong-Jae;Park, Jong-Gwon;Lee, Hu-Sang
    • 한국기계연구소 소보
    • /
    • s.20
    • /
    • pp.21-26
    • /
    • 1990
  • In order to satisfy the industrial requirements to measure the rotational error motion of main spindles and to find out the source of the error motion, some measuring systems were made. Their measuring principle are based on the 3-point roundness measurement. In these measuring systems, the measurements are processed by digital calculation technique and the form error and the rotational error motion of main spindles are spearated. In the present paper, the principle of 3-point metnod is introduced and some application examples are shown.

  • PDF