• Title/Summary/Keyword: Oscilloscope

Search Result 230, Processing Time 0.026 seconds

$LP_{11}$ Mode Fiber Optic Resonant Ring Interferometer with a $LP_{11}$ Modal Filter ($LP_{11}$ 결모양 빛살거르게를 사용한 $LP_{11}$ 결모양 빛살 광섬유 공진고리 간섭계)

  • 이현재;이두희;서상준;양진성
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.20-25
    • /
    • 1991
  • Using evanescent field coupling between single ($LP_{01}$) and double ($LP_{01}, LP_{11}$) mode optical fiber, we selected LPII mode beam. With a $LP_{11}$ mode beam from a double mode fiber. we fabricated $LP_{11}$ mode fiber optic resonant ring interferometer, and assured that the guided mode is $LP_{11}$ mode from a radiation beam coming through the prism output coupler. When an external perturbation applied to the signal arm of the $LP_{11}$ fiber optic resonant ring interferometer, we examined the change of radiation mode coming from a prism output coupler and an end of optical fiber. Using two photodiode, LPn mode beam converted to voltage. This two output voltages is applied to X and Y terminal of oscilloscope to display circular motion on oscilloscope.

  • PDF

The three-dimensional temporal behavior measurement of light emitted from plasma display panel by the Scanned Point-Detecting System (Scanned Point-Detecting System을 이용한 플라즈마 디스플레이 패널에서 방출되는 광의 3차원 시간 분해 측정)

  • 최훈영;이석현;이승걸;김준엽
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.559-563
    • /
    • 2002
  • We measure the 3-dimensional temporal behavior of the light emitted from the discharge cell of a plasma display panel (PDP) by using a scanned point detecting system. The light signal detected by a PM tube is sent to the oscilloscope, and the oscilloscope is connected to a PC with GPIB. From the resultant temporal behaviors, we could analyze the discharge characteristics of the panel with a Ne-Xe (4%) mixing gas at a 400 torr pressure. The top view of the panel shows that discharge moves from the inner edge of the cathode electrode to the outer cathode electrode, forming an arc shape. The side view of the panel shows that the light is detected up to 150 $\mu\textrm{m}$ up the barrier rib. After a trigger pulse is applied, peak intensity is detected at 730 ns and peak intensity position is located at the center of the ITO electrodes.

Mechanical Behavior of Fruits under Impact Loading (과실의 충격특성에 관한 연구)

  • Hong J. H.;Myung B. S.;Choe J. S.;Kim C. S.;Kim T. W.;Chung J. H.;Park J. W.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.5 s.112
    • /
    • pp.274-279
    • /
    • 2005
  • Impact is one of the major cause of damage to fruits druing varios processes from the production on the farm to the consumer. The tissue of fruits are ruptured in a very short period time less than 10ms by impact loading. Mechanical behavior of fruits under impact loading can be analyzed better with high speed sampling data acquisition system and one of them is a digital storage oscilloscope. A impact test system was developed to test the physical properties of fruits including apple, pear, and peach which may lead to a better understanding of the physical laws. The test system consisted of a digital storage oscilloscope and simple mechanism which can apply impact force to fresh produce. Rupture force, energy, and deffrmation were measured at the five levels of drop heights from 4 to 24cm fur each internal and external tissues. Rupture forces for apple and pear were in the range of 72.9 to 87.7 N and 70.8 to 84.1 N for external and internal tissues, respectively. Rupture forces far peach external tissues were in the range of 43.4 to 65.0 N.

Design and Making of PWM Control-based AC-DC Converter with Full-Bridge Rectifier (전파 정류기를 가지는 PWM 제어 기반의 AC-DC 컨버터 설계 및 제작)

  • Bum-Soo Choi;Sang-Hyeon Kim;Dong-Ki Woo;Min-Ho Lee;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.617-624
    • /
    • 2023
  • Recently, miniaturization and low power consumption of electronic products and improved efficiency and power factor improvement have become a matter of great interest. In this paper, an AC-DC converter based on PWM control was designed and made. The AC-DC converter is designed with a structure in which one rectifier circuit and one output voltage control circuit are connected in series. The rectifier circuit is a diode-based single phase full-wave current circuit and the output voltage control circuit is a DC-DC conversion circuit based on PWM control. Arduino was used as the main control device for PWM control, and LCD was configured at the output stage so that the control result could be checked. The error between the output voltage displayed on the oscilloscope and LCD and the target output voltage was confirmed through repeated experiments with the test circuit, and the validity of the proposed design methodology was confirmed by showing an error rate of about 5% based on the oscilloscope measurement value.

A Study on the Step-up DC-DC Converter for PV System Application Under Variable Input Voltage Condition (가변 입력 전압 조건하에서 태양광 시스템 적용을 위한 승압형 DC-DC 컨버터 연구)

  • Ju-Yeop Lee;Se-Cheon Oh;Il-Hyeong Jo;Ye-Jin Kim;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.677-684
    • /
    • 2024
  • In this paper, the design method of a step-up DC-DC converter based on PWM control was studied for solar power system application. The operating principle of the switching mode step-up type DC-DC converter was analyzed and the basic design method was studied. For photovoltaic system application, an output voltage feedback control algorithm based on PWM control was developed to enable the converter's output voltage to follow the target voltage under variable input conditions. As a procedure to verify the effectiveness of the proposed algorithm, a prototype of a step-up DC-DC converter with a single feedback output voltage was designed and made by boosting the input voltage DC 10V to DC 30V. In experiments with prototypes, it was confirmed that the output voltage of the oscilloscope and LCD accurately followed the target output voltage. In the performance evaluation test, it was confirmed that the output voltage of the oscilloscope and LCD accurately followed the target output voltage by showing an error rate within 1 [%] of the reference voltage.

Comparison of turn-on/turn-off transient in Electron Irradiated and Proton Irradiated Silicon pn diode (전자와 양성자를 조사한 PN 다이오드의 turn-on/turn-off transient 특성 비교)

  • Lee, Ho-Sung;Lee, Jun-Ho;Park, Jun;Jo, Jung-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1947-1949
    • /
    • 1999
  • Carrier lifetime in silicon power devices caused switching delay and excessive power loss at high frequency switching. We studied transient turn-on/turn-off transient characteristics of electron irradiated and proton irradiated silicon pn junction diodes. Both the electron and proton irradiation of power devices have already become a widely used practice to reduce minority carrier lifetime locally[1]. The sample is n+p junction diode, made by ion implantation on a $20\Omega.cm$ p-type wafer. We investigated turn-on/turn-off transient & breakdown voltage characteristics by digital oscilloscope. Our data show that proton irradiated samples show better performance than electron irradiated samples.

  • PDF

Dynamic Respeonse of Hydraulic Pipe Lines with a Relative Small Diameter (직경이 작은 유압관로에서의 동특성)

  • 유영태
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.38-44
    • /
    • 1999
  • This paper primarily directed toward analyzing the frequency response in hydraulic pipe lines with a small diameter. The exact solution to the frequency response is obtained by using the complicated transfer function. The discrepancy with the exact and the approximate is small so the approximation solution is adopted to compare the experimental results with the theoretical analysis. In this experiment the input frequency was generated by the frequency generator with the ball valve and speed controller. In order to compare the theoretical were forms with the experimental ones the trace obtained from the oscilloscope is photographed, The diameter the length of lines and input pressure amplitude are varied to investigate their effects,. the experiment results show that th values of dimensionless parameter are very affected to the phase delay and guide response time in the design of pressure manifold to measure the pressure of hydraulic pipelines.

  • PDF

Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil (유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰)

  • Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

GISPD Measurement Using UHFPD Measurement System (UHFPD측정시스템을 이용한 GISPD측정)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1857-1859
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the noise suppression methods and the PD measurement results of the in-service substation by the developed UHF PD measurement system which consists of the external UHF coupler, the UWB LNA and the digital storage oscilloscope. As results, it was found that the effect of the noise suppression methods were verified and that the developed external UHF coupler showed a better detection sensitivity than a conventional external coupler.

  • PDF

GISPD Analysis Using UHF Dual-Band Method (UHF이중대역법을 이용한 GISPD분석)

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Choi, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF