• 제목/요약/키워드: Oscillation Control

검색결과 498건 처리시간 0.023초

Design of Digital Controller for Uninterruptible Power Supply Using Disturbance Observer

  • Cho, Jun-Seok;Lee, Seung-Yo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.830-835
    • /
    • 1998
  • This paper describes a new digital control method of 3-phase PWM inverter with LC filter for uninterruptible power supply(UPS). The overall control system is based on the dead beat control, which has the minor loop of current control within the voltage control major loop. In this paper, the full-order disturbance observer is proposed to compensate the disturbances generated due to a sudden change of load currents. The proposed disturbance observer is composed of dead beat observer which estimates state values within a finite time, and cancels the disturbances by adding feedforward compensation loop in the control system. In addition, on order to remove a defect of oscillation generated in output of conventional dead beat controller, a modified dead beat algorithm is proposed in this paper.

  • PDF

SISO 비선형 시스템의 제어를 위한 퍼지 모델 기반 제어기 (The Fuzzy Model-Based-Controller for the Control of SISO Nonlinear System)

  • 장욱;권오국;주영훈;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.528-530
    • /
    • 1998
  • This paper addresses analysis and design of a fuzzy model-based-controller for the control of uncertain SISO nonlinear systems. In the design procedure, we represent the nonlinear system by using a Takagi-Sugeno fuzzy model and construct a global fuzzy logic controller via parallel distributed compensation and sliding mode control. Unlike other parallel distributed controllers. this globally stable fuzzy controller is designed without finding a common positive definite matrix for a set of Lyapunov equations, and has good tracking performance. Furthermore, stability analysis is conducted not for the fuzzy model but for the real underlying nonlinear system. A simulation is included for the control of the Duffing forced-oscillation system, to show the effectiveness and feasibility of the proposed fuzzy control method.

  • PDF

A Feedback Control System for Suppressing Crane Oscillations with On-Off Motors

  • Hekman, Keith A.;Singhose, William E.
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권3호
    • /
    • pp.223-233
    • /
    • 2007
  • Crane payloads frequently swing with large amplitude motion that degrades safety and throughput. Open-loop methods have addressed this problem, but are not effective for disturbances. Closed-loop methods have also been used, but generally require the speed of the driving motors to be precisely controlled. This paper develops a feedback control method for controlling motors to cancel the measured payload oscillations by intelligently timing the ensuing on and off motor commands. The effectiveness of the oscillation suppression scheme is experimentally verified on an industrial bridge crane.

다이나믹 전류보상기를 이용한 V/f 제어 유도전동기 드라이브 시스템의 안정도 향상 (Stability Improvement of a V/f Controlled Induction Motor Drive System using a Dynamic Current Compensator)

  • 정강률
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.402-408
    • /
    • 2004
  • This paper proposes the novel V/f control method to improve the stability of a V/f controlled induction motor drive system. The conventional V/f control method used in the proposed V/f control method is a vector-based method that is slightly different from the existing conventional V/f control method. The proposed control method uses a dynamic current compensator to improve the stability of a V/f controlled induction motor drive system. This proposed method is easy to implement and completely eliminates the motor oscillation phenomenon causing the instability of a V/f controlled induction motor drive system, especially when the system is driven near the resonant frequency in steady-state with light load. Additionally, this paper analyzes theoretically the instability of a V/f controlled induction motor drive system and shows the validity of the Proposed V/f control method through simulation and experimental results.

최적 제어법에 의한 타워크레인의 자동화에 관한 연구 (Automation of Tower Cranes based on Optimal Control Method)

  • Lee, Jin-Woo;Kim, Sang-Bong
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.213-222
    • /
    • 1993
  • 본 논문은 하역작업이나 제품의 권상, 권하시 타워크레인의 로바스트 콘트롤을 고려한 타워크레인의 자동화에 관한 것이다. 본 논문을 위한 타워크레인의 모델방정식은 라그랑즈 방정식을 사용하였으며, 동방정식은 평행점 근방에서 선형화 하였다. 본 논문의 제어법으로서는 최적 레규레타법을 적용하였으며, 그 효용성은 설계된 최적 제어법을 위하여 16비트 마이크로컴퓨터를 이용하여 카고로우프의 진동제어와 그레인의 붐 및 트로리의 위치제어를 위한 실험결과로써 입증되었다.

  • PDF

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.

HDD 액츄에이터를 위한 관측기 기반하의 견실 제어기 설계 (Observer-based Robust Controller Design for HDD Actuator)

  • 신동균;변지영;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.26-28
    • /
    • 2004
  • The sliding mode control law provides a robust solution for general control problems. Most real systems which use a portable hard disk drive have to overcome disturbances and model uncertainties for proper operation. The chattering effect caused from unexpected oscillation can make the system be unstable. Therefore, we propose a robust control algorithm for the nonlinear second order systems with model uncertainties and disturbances. The proposed algorithm is designed following a sliding mode and observer based control. Thus the proposed algorithm has more expanded bounded region of control. Simulation results show the robustness of the proposed controller.

  • PDF

Nanoscale Dynamics, Stochastic Modeling, and Multivariable Control of a Planar Magnetic Levitator

  • Kim, Won-Jong
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.1-10
    • /
    • 2003
  • This paper presents a high-precision magnetically levitated (maglev) stage to meet demanding motion specifications in the next-generation precision manufacturing and nanotechnology. Characterization of dynamic behaviors of such a motion stage is a crucial task. In this paper, we address the issues related to the stochastic modeling of the stage including transfer function identification, and noise/disturbance analysis and prediction. Provided are test results on precision dynamics, such as fine settling, effect of optical table oscillation, and position ripple. To deal with the dynamic coupling in the platen, we designed and implemented a multivariable linear quadratic regulator, and performed time-optimal control. We demonstrated how the performance of the current maglev stage can be improved with these analyses and experimental results. The maglev stage operates with positioning noise of 5 nm rms in $\chi$ and y, acceleration capabilities in excess of 2g(20 $m/s^2$), and closed-loop crossover frequency of 100 Hz.

가변 이득을 가지는 단상 PFC 디지털 제어기 (The Digital Controller of the Single-Phas Power Factor Correction(PFC) having the Variable Gain)

  • 정창용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2000
  • This paper presents the digital control of single-phase power factor correction(PFC) converter which has the variable gain according to the condition of inner control loop error. Generally the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This has a bad influence on the power factor because current loop doesn't operate smoothly in the condition that input voltage is low In particular a digital controller has more time delay than an analog controller and degrades This drops the phase margin of the total digital PFC system,. It causes the problem that the gain of current control loop isn't increased enough. In addition the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult The digital PFC controller presented in this paper has a variable gain of current control loop according to input voltage. The 1kW converter was used to verify the efficiency of the digital PFC controller.

  • PDF

원통형 연소기에서의 열-덕트 연성 소음의 능동 제어 연구 (Active Control Method of Heat-Duct Coupled Noise in a Cylindrical Combustor)

  • 조상연;이용석;엄승신;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.678-683
    • /
    • 1998
  • Combustion instability by thermoacoustic feedback incite strong low frequency noise and vibration which damage the system and provoke the environmental problems. Therefore, it is necessary to control the thermoacoustic oscillation. In the way of controlling the instability, active control method using adaptive algorithm is applied. In this study, active noise control method using anti-sound technique is selected, whose principle is cancelling the noise with the addition of opposite phase sound. At first, simulation is performed to confirm the stability of controller, and after that control of combustion instability is carried out to get cancellation of 20-30dB SPL.

  • PDF