• Title/Summary/Keyword: Orthodontic miniscrews

Search Result 45, Processing Time 0.024 seconds

Comparison of insertion torque regarding changes in shape, diameter, and length of orthodontic miniscrews (교정용 미니스크류의 형상에 따른 식립 토오크의 비교)

  • Lim, Seon-A;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.89-97
    • /
    • 2007
  • Objective: The purpose of this study was to measure the insertion torque of orthodontic miniscrews regarding changes in their shape, diameter, and length. Methods: Torque values were measured during continuous insertion of the miniscrews into solid rigid polyurethane foam, using a torque tester of driving motor type with a regular speed of 3 rpm. Orthodontic miniscrews (Biomaterials Korea, Seoul, Korea) of cylindrical type and taper type were used. Results: Increasing the length and diameter of the miniscrews increased the maximum insertion torque value in both cylindrical and taper type screws. Insertion torque was increased at the incomplete head of the cylindrical type screw, and at the tapered part of the taper type screw. The insertion torque value of miniscrews was influenced most by diameter, then shape and length. As a result, it was shown that the diameter of the screw had the most influence on insertion torque, and the taper type screw had a higher torque value than the cylindrical type screw. Conclusion: Therefore, a large diameter or taper type screw are adequate for areas of thin cortical bone with a large interdental space, and a small diameter or cylindrical type screw are adequate in the mandibular molar area or the midpalatal area having thick cortical bone.

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

Miniscrews versus surgical archwires for intermaxillary fixation in adults after orthognathic surgery

  • Son, Sieun;Kim, Seong Sik;Son, Woo-Sung;Kim, Yong-Il;Kim, Yong-Deok;Shin, Sang-Hun
    • The korean journal of orthodontics
    • /
    • v.45 no.1
    • /
    • pp.3-12
    • /
    • 2015
  • Objective: We compared the skeletal and dental changes that resulted from the use of two methods of intermaxillary fixation (IMF)-miniscrews and surgical archwire-in 74 adult patients who had Class III malocclusion and were treated with the same orthognathic surgical procedure at a hospital in Korea. Methods: All the patients underwent Le Fort I osteotomy and bilateral sagittal split ramus osteotomy with rigid fixation. They were divided into two groups according to the type of IMF used-group 1 underwent surgical archwire fixation and group 2 underwent orthodontic miniscrew fixation. In a series of cephalograms for each patient, we compared vertical and horizontal tooth-position measurements: (a) immediately after surgery ($T_0$), (b) 3 months after surgery ($T_1$), and (c) 6 months after surgery ($T_2$). Cephalometric changes within each group were examined using one-way analysis of variance (ANOVA) while the independent samples t -test procedure was used to compare the two groups. Results: After surgery, the maxillary incisors tended to be proclined in both groups although there were no significant differences. Incisor overbite increased significantly in both groups from $T_0$ to $T_1$, and the miniscrew group (group 2) showed slightly greater overbite than the archwire group (group 1). Conclusions: This study suggest that the use of orthodontic miniscrews and orthodontic surgical archwire for IMF in adult patients results in similar skeletal and dental changes.

Comprehensive Orthodontic Treatment in a Middle-Aged Patient with Missing Maxillary Left First Premolar: A Case Report

  • Kwon, Sun-Mi;Baik, Hyoung-Seon;Choi, Sung-Hwan
    • Journal of Korean Dental Science
    • /
    • v.11 no.1
    • /
    • pp.32-41
    • /
    • 2018
  • As the adult population continues to increase, orthodontic treatment for adult patients is becoming more common. This case report describes comprehensive orthodontic treatment of a middle-aged patient with closure of the extraction space without prosthetic restoration. A 55-year-old woman with her maxillary left first premolar extracted because of a periodontal problem, wanted to close the space with orthodontic treatment. Since she had generalized crowding and mild skeletal discrepancy, we planned comprehensive orthodontic treatment, including closure of the extraction space by protraction of the left maxillary molars using miniscrews and aesthetic alignment of anterior teeth. The total treatment period was 28 months. As a result of these treatments, the extraction space was successfully closed, good tooth alignment and satisfactory occlusion were achieved.

Orthodontic-prosthodontic interdisciplinary treatment for a patient with multiple missing posterior teeth and unilateral scissors bite (다수의 구치 상실과 편측성 가위교합을 갖는 환자의 보철 교정 협진 치료)

  • An, Kiyong
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.844-854
    • /
    • 2015
  • This clinical report describes an orthodontic-prosthodontic interdisciplinary treatment for a patient with multiple missing teeth and unilateral scissors bite. A 47-year-old female presented with multiple missing posterior teeth, anterior large overjet, deep bite, and posterior scissors bite on the right premolar area. Periodontal therapy was performed and followed by orthodontic treatment. The maxillary anterior teeth were initially aligned, then two implants were placed for the left mandibular molars to increase occlusal vertical dimension. The scissors bite between the right maxillary and mandibular premolars were corrected using the miniscrews as an anchorage. Other implants were placed for the right maxillary and mandibular molars after the occlusal planes and occlusal relationship were harmonized. The patient adapted well to altered vertical dimension without any specific problems including peri-implant marginal bone loss. Interdisciplinary approach resolve the complex orthodontic-prosthodontic problems and concluded in successful results.

THE USE OF MINISCREWS FOR TOOTH MOVEMENT IN CHILDREN (성장기 아동에서 miniscrew를 고정원으로 이용한 치아이동)

  • Kim, Sang-Min;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.537-544
    • /
    • 2010
  • Anchorage control in orthodontic treatment is an important factor affecting treatment results. In the conventional approach, intra-oral anchorage such as application of differential force and moment, Nance holding arch and lingual arch, as well as extra-oral anchorage such as head gear were used for anchorage reinforcement. However, these anchorages may result in undesired tooth movement and require patient cooperation. To overcome these disadvantages, skeletal anchorage system was introduced as orthodontic anchorage. Types of skeletal anchorage include implant, onplant, miniplate and miniscrew. Especially, miniscrew has many advantages such as reduced patient cooperation, low cost and easy placement. Recently, it is successfully used in orthodontic treatment. This cases were treated using orthodontic miniscrews for retraction of ectopically erupting maxillary canine and impacted mandibular canine and intrusion of maxillary incisors.

Complications reported with the use of orthodontic miniscrews: A systematic review

  • Giudice, Antonino Lo;Rustico, Lorenzo;Longo, Miriam;Oteri, Giacomo;Papadopoulos, Moschos A.;Nucera, Riccardo
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-216
    • /
    • 2021
  • Objective: The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence. Methods: A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment. Results: The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis. Conclusions: These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

Effect of Laser Pre-Drilling on Insertion Torque of Orthodontic Miniscrews: A Preliminary Study

  • Kim, Keun-Hwa;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.66-73
    • /
    • 2017
  • Purpose: To evaluate the effect of different-sized drill tips and laser irradiation times on the initial stability of orthodontic miniscrews placed in Er,Cr:YSGG-laser pre-drilled holes in an animal model. Materials and Methods: Laser pre-drilled holes were made in dog mandibular bone with an Er,Cr:YSGG laser using irradiation times of 5, 7, 9, 11, and 13 seconds, and tip diameters of 0.4 and 0.6 mm. The maximum diameter and depth of the pre-drilled holes was measured with micro computed tomography. The maximum insertion torque was measured during placement the miniscrew. Result: Laser pre-drilled holes were conical shaped. The maximum diameter of pre-drilled holes increased with longer laser irradiation times (P>0.05) and larger tip diameters (P<0.05). The depth of pre-drilled holes increased with longer laser irradiation times and larger tip diameters (P<0.05). When the 0.4 mm tip, but not the 0.6 mm tip, was used, the insertion torque decreased significantly with longer laser irradiation times (P<0.05). Conclusion: Tip diameter impacted insertion torque more than irradiation time. It takes at least 9 seconds using a 0.6 mm tip to create a 0.8 mm diameter and 1.0 mm depth hole in thick cortical bone.

Scar formation and revision after the removal of orthodontic miniscrews

  • Choi, Yoon Jeong;Lee, Dong-Won;Kim, Kyung-Ho;Chung, Chooryung J.
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.146-150
    • /
    • 2015
  • Many clinicians expect complete healing after the removal of temporary anchorage devices, but clinical examination may reveal scar-like tissue. This report presents the typical features of scarring detected after the removal of miniscrews, and the clinical outcome of scar revision along with its pathologic features.

Managing Short Root Anomalies in Pediatric Cancer Survivors: Utilizing Resin Wire Splints and Miniscrews for Skeletal Anchorage

  • Taegyoung Kim;Namki Choi;Seonmi Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.88-98
    • /
    • 2024
  • Patients with pediatric cancer often undergo multiple therapies, such as chemotherapy, radiation therapy, and stem cell transplantation. These treatments, while essential, can result in dental developmental issues, including hypodontia, microdontia, short roots, and delayed dental development. This report presents two cases of pediatric patients diagnosed with neuroblastoma who exhibited severe tooth mobility due to short roots as a complication of cancer treatment. Moreover, we investigated the conservative management of the patients' conditions using resin wire splints and orthodontic miniscrews for skeletal anchorage along with long-term follow-ups to evaluate their prognosis.