• Title/Summary/Keyword: Orifice size

Search Result 190, Processing Time 0.034 seconds

A study on spray characteristics of the triplet impinging stream type injector for liquid rocket (액체 로켓용 충돌형 Triplet 인젝터의 미립화 특성에 관한 연구)

  • Park, Sung-Young;Kim, Seon-Jin;Park, Seung-Woon;Kim, Yoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1005-1014
    • /
    • 1996
  • An experimental investigation has been carried out to examine the influence of injector design variables and operating conditions on the resultant drop size for triplet impinging streams injectors. The variables studied in this investigation are pressure drop, impinging angle, orifice length to diameter ratio, and impinging point distance. Droplet-size data are obtained using water as the propellant simulant by Malvern Particle Analyzer System. Drop size decreases with increasing impinging angle and pressure drop while other injector parameters remain constant at the same point. But it is found that there is no noticeable droplet-size change which results from change in orifice length to diameter ratio or impinging point distance within the investigated range.

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Development and Performance Evaluation of a Liquid Particle Generator (액적 발생 장치 개발 및 성능 평가)

  • Heo, Jung-Hyuk;Kim, Dae-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4334-4340
    • /
    • 2012
  • In this work, we developed and evaluated the Liquid Particle Generator for generating fine particles in the air. The Liquid Particle Generator, which was based on the spray-evaporation method, had two kinds of orifices: 0.3 mm and 0.5 mm. The Liquid Particle Generator was operated at different pressure between 1 bar and 4 bars to find relationship between input pressure and droplet output rate. In addition, the size distribution of the droplets generated by the Liquid Particle Generator with different orifices was measured by the SMPS system and the optical particle counter. As a result, it was shown that the Liquid Particle Generator with 0.3 mm orifice generated droplets of around 0.3 ${\mu}m$ and atomized particles very stably. The Liquid Particle Generator having 0.5 mm orifice generated bigger droplets, compared with the Liquid Particle Generator with 0.3 mm orifice. Additionally, in these Liquid Particle Generators (0.3 mm and 0.5 mm orifice), little coagulation of particles did occur because of fine droplets atomized by the jet. Therefore, the Liquid Particle Generator could be used as an aerosol generator for atomizing fine particles.

Development of Swirl Disc Nozzles for Knapsack Sprayers (배부식 방제기를 위한 디스크형 노즐 개발)

  • Gwak H.H.;Kim Y.J.;Rhee J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.153-160
    • /
    • 2006
  • This study was performed to evaluate some geometrical characteristics of disc type swirl nozzles and to develop nozzles having improved spraying performance for knapsack sprayers. Considered geometrical characteristics of the nozzles were disc thickness, orifice diameter, swirl chamber diameter and shape of the swirl chamber (nozzle chamber). 3 types of nozzle cores were compared. Main results of this study were as follows. 1. Spraying angle (A) was increased with decreasing disc thickness (x), and with increasing orifice diameter (y) or spraying pressure (z). The equation was as a follow. $$A=3.95\frac{1}{x}+73.50\sqrt{y}+18.97\sqrt{z}-60.16$$ 2. Spraying flow rate (F) was increased with decreasing disc thickness (x), and with increasing orifice diameter (y) or spraying pressure (z). The equation was as a follow. $$F=-89.95x+611.09y+620.49\sqrt{z}-868.20$$ 3. Mean spraying droplet size (V) was decreased with decreasing disc thickness (x), with increasing orifice diameter (y) in low spraying pressure, with decreasing orifice diameter (y) in high spraying pressure, and with increasing spraying pressure (z). $$V=148.77x^4-746.85x^3+1311.76x^2-917.31x$$ 4. The spray pattern was compared using CV values. The CV value of the nozzle core type 1 was 26.7% in spraying pressure $3\;kgf/cm^2$, the CV value of the core type 2 was 23.6% in spraying pressure $2\;kgf/cm^2$, the CV value of the core type 3 was 20.6% in spraying pressure $1\;kgf/cm^2$. 5. Minimum spraying pressure was improved from $1.5\;kgf/cm^2\;to\;1.0\;kgf/cm^2$ by changes of nozzle core shape.

An Experimental Study on the Orifice Nozzle System that Generates Micro-bubbles by Self-suction of Air with a Recirculating Flow (재순환 유동 공기 자가흡입에 의한 마이크로버블 발생 오리피스 노즐 시스템에 대한 실험적 연구)

  • Oh, Shin-il;Park, Sang-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.82-88
    • /
    • 2018
  • An experimental study was performed on the orifice nozzle system that generates micro-bubbles by air self-suction using a venturi nozzle. This study experimentally investigates the amount of air sucked into the venturi nozzle and the number of micro-bubbles generated by the orifice nozzle system in Cases 1 and 2. The experimental conditions were varied by changing the diameter of the orifice nozzle (d=2~7 mm) and the number of holes of the perforated plate nozzle (n = 2-12). In Case 1, the air self-suction was more than 2 LPM at $d{\leq}4mm$. When d = 4 mm, the total number of bubbles was 29,777, and it was confirmed that micro-bubbles occupied approximately 65% of the total number of bubbles. In Case 2, the air self-suction was maintained constant at approximately 2.5 LPM regardless of the number (n) of holes. The total amount of bubbles increased when n increased but remained constant at approximately 44,000 when $n{\geq}7EA$. It was also confirmed that more than 80% of all bubbles were micro-bubbles when $n{\geq}10EA$. Thus, the number of micro-bubbles increased by approximately 15% compared to the experimental result of Case 1, which was optimized with d = 4 mm.

Design of Sharp-edged Type Damping Orifices for an Aircraft Door Damper (민항기 door damper용 칼날형 댐핑 오리피스의 설계)

  • Hong, Yeh-Sun;Kwon, Yong-Cheol;Kim, Chong-Hyeok;Park, Seol-Hye;Park, Ho-Yeol;Kim, Sang-Beom
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1080-1085
    • /
    • 2012
  • In this paper a sharp-edged type damping orifice for an aircraft door damper were designed, where the dynamic viscosity of working fluid were assumed to change up to 400cSt. The discharge coefficient of the damping orifice were investigated by CFD analyses and experiments. In particular, the influences of orifice diameter, edge angle, flow direction and the Reynolds number were taken into consideration. Based on this, it has been deduced how high Coulomb friction forces of damper seals is to be allowed to meet the performance criterion with respect to the orifice size.

Evaluation of Various Synthesis Methods for Calcite-Precipitated Calcium Carbonate (PCC) Formation

  • Ramakrishna, Chilakala;Thenepalli, Thriveni;Ahn, Ji Whan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.279-286
    • /
    • 2017
  • This review paper evaluates different kinds of synthesis methods for calcite precipitated calcium carbonates by using different materials. The various processing routes of calcite with different compositions are reported and the possible optimum conditions required to synthesize a desired particle sizes of calcite are predicted. This paper mainly focuses on that the calcite morphology and size of the particles by carbonation process using loop reactors. In this regard, we have investigated various parameters such as $CO_2$ flow rate, Ca $(OH)_2$ concentration, temperature, pH effect, reaction time and loop reactor mechanism with orifice diameter. The research results illustrate the formation of well-defined and pure calcite crystals with controlled crystal growth and particle size, without additives or organic solvents. The crystal growth and particle size can be controlled, and smaller sizes are obtained by decreasing the Ca $(OH)_2$ concentration and increasing the $CO_2$ flow rate at lower temperatures with suitable pH. The crystal structure of obtained calcite was characterized by using X-ray diffraction method and the morphology by scanning electron microscope (SEM). The result of x-ray diffraction recognized that the calcite phase of calcium carbonate was the dominating crystalline structure.

The Flow Characteristics of Fuel Droplets between the Twin Spray for 4-hole Gasoline Injectors (4공 가솔린 분사기의 2중 분무 사이에서 연료 액적들의 유동특성)

  • Kim, Won-Tae;Kang, Shin-Jae;Rho, Byung-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.484-495
    • /
    • 2003
  • This study investigates the flow characteristics of fuel droplets between twin spray for the 4-hole injector used a 4-valve gasoline engine. The injectors for this study were the three types of 4-hole gasoline injector in which orifice diameter was 0.24mm. The spray behavior of twin spray was investigated by means of visualization employed stroboscope. A PDPA system was employed to simultaneously measure the size and velocity of fuel droplets. The 3 dimensional mean velocities. droplet size distributions, SMD and joint probability density function of velocity and droplet size are analyzed at the center of the spray and the center region of twin spray. As a result, the configurations of injector exit such as orifice interval and length of outlet, are very important factors that affect the flow characteristics of fuel droplets at the center region of twin spray.

A Study on Parameters of SUAV Landing Gear Orifice (SUAV 착륙장치 오리피스의 파라미터 연구)

  • Han, Jae-Do;Kang, Yeon-Sik;Ahn, Oh-Sung;Lee, Young-Sin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.99-104
    • /
    • 2009
  • In this paper, the drop characteristic of the small aircraft landing gear of SUAV has been analyzed and performed on orifice optimal design for shock absorption efficiency. The SUAV landing gear was simple oleo pneumatic type without metering pin. The landing gear was modelled by MSC ADAMS software. Drop test evaluation was conducted to confirm the analysis model. As a result of correlation between analysis and test results, it was verified that these results were coincided with very well. After confidence review of analysis model through the correlation between test and analysis results, design parametric study was performed by using confirmed analysis model. Optimal orifice size with best efficiency have been decided in this study.

An Experimental Study of the Spray Characteristics for an Oxidizer-rich Preburner Injector (산화제 과잉 예연소기 인젝터의 분무 특성에 관한 연구)

  • So, Y.S.;Yang, J.H.;Han, Y.M.;Choi, S.M.
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The spray characteristics of the oxidizer-rich preburner are investigated. This system is generally operated at an oxidizerfuel mixture ratio of 50. The spray quality and mixing performance are very important for safe combustion. To know the spray characteristics of the oxidizer-rich preburner, we have designed various swirl injectors and measured droplet velocity and size by the PDPA system. The flow discharge coefficient of the fuel orifice is $0.12{\sim}0.21$, oxidizer orifice discharge coefficient is $0.16{\sim}0.28$. From the spray visualization, fuel nozzle spray angle is $15^{\circ}{\sim}25^{\circ}$, oxidizer nozzle spray angle is $65^{\circ}{\sim}85^{\circ}$ and combined spray angle is reduced $2^{\circ}{\sim}5^{\circ}$ compared to the oxidizer nozzle only case. From the PDPA measurement, droplet SMD is $175\;{\mu}m$ at 50 mm and $190\;{\mu}m$ at 100 mm of variant 1 combined case. The number concentration measurement revealed the reason of the droplet diameter increasement with distance. That is due to drop coalescence results from collision of drops which is occurred in dense sprays at a long distance from nozzle orifice exit.

  • PDF