• 제목/요약/키워드: Organic wastewater

검색결과 1,238건 처리시간 0.032초

용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구 (Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

수질오염총량관리제에서 난분해성 유기물질 관리 필요성 및 개선방안 (Necessity of Refractory Organic Matters Management in Total Maximum Daily Loads (TMDLs))

  • 박재홍;박배경;이재관;류덕희
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.393-399
    • /
    • 2013
  • To control organic matters, it needs to manage not only biodegradable organic matters but also refractory organic matters. Refractory organic matters from municipal wastewater, industrial wastewater, non-point sources and etc., have been continuously discharged to the near watersheds. It is estimated that the refractory organic matter ratios are continuously increased in waterbody. In watersheds of the Total Maximum Daily Loads (TMDLs), it was investigated that COD/BOD ratios increased in many unit watersheds of the 4 major river basins. The portions COD/BOD ratios increased were found to be a 97% of Geum River unit watersheds, a 81% of Yeongsan/Seumjin River unit watersheds, a 78% of Nakdong River unit watersheds, a 70% of Han River unit watersheds, respectively. Therefore, it has become important for establishment of effective management strategies to control refractory organic matter in watersheds of the Total Maximum Daily Loads (TMDLs). In order to properly manage organic matters including refractory organic matters, the present organic indicator (BOD) has to be converted to TOC (or COD). Compared to COD and BOD, TOC, as a organic matter indicator, is evaluated more appropriate.

정수 슬러지로부터 알루미늄 응집제의 회수에 관한 연구 (Recovery of Aluminium Coagulants from Water Treatment Plant Sludges)

  • 이재복;황정욱;김진재
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.30-40
    • /
    • 1998
  • Increasing water consumption produced sludge problems of the water treatment plants. The objective of this study is to investigate aluminium coagulants recovery n acidic and alkaline conditions. Water treatment plant sludge produced in Pusan Metropolitan City were tested for the aluminium extraction process. Experiment samples were obtained in summer from water treatment plants of Deoksan and Myongjang. Aluminium coagulants used in these plants during the test period were polyaluminium chloride(PAC), polyaluminium sulfate organic(PSO), polyaluminium sulfate silicate(PASS). Aluminium contents of water treatment sludge were in the range of 7.2~10.9% of the total solids. The recovery percentages for aluminium and iron by acidic extraction method was evaluated to 88% and 42% respectively. Extracted mass variation for other materials such as iron, manganese, total organic carbon was observed during the extraction operation. Alkaline extraction produced more than two times amount of total organic carbon than that in the acidic extraction process.

  • PDF

Ejector형 포기장치를 이용한 식품가공폐수를 처리 (Food Processing Wastewater Treatment with Ejector-Type Aerator)

  • 정용현
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.221-225
    • /
    • 1999
  • This study was conducted to evaluate the treatment efficiency including reaction kinetics and hydraulic characteristics of food processing wastewater by using an ejector-type aeration system (ETAS) in activated sludge process. The oxygen transfer efficiency in ETAS can be changed in accordance with the depth of reactor. However, the optimum air velocity was found less than 1.82 m/hr at a superficial liquid velocity of 634 m/hr. The ETAS process showed higher organic material removal efficiency than that of the existing activated sludge process under hydraulic detention time 6 to 12 hours. This process, which can maintain MLVSS highly, is able to have high organic material removal efficiency at short HRT and deal with variable organic material loading.

  • PDF

담체 모양변화에 따른 유기물 처리 성능 고찰 (Performance of Organic Treatment with Shape Modify of Ceramic Support Carrier)

  • 박영식;안갑환
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.27-34
    • /
    • 2001
  • This paper discussed the shape effect of ceramic support carrier in order to facilitate biomass immobilization. The shape of ceramic support carrier was modified hollow pipe type into hollow gear type. After seeding, microorganisms were attached in crevices where protection from shear forces or surfaces where easy to contact with support carrier surface. In case of hollow gear type carrier, initial attachment rate was faster than that of hollow pipe type and obtained thick biofilm. Synthetic wastewater(COD:75~880 mg/L, organic loading rate:0.36~4.22 kgCOD/㎥.d) was treated aerobic fixed bed biofilm reactor where 100% of the volume was filled with the ceramic carrier. COD removal efficiency of reactor filled with gear type support carrier was a little high withing 70 days, and then showed similar removal efficiency. It was found that highly loaded operation with up to 4.22 kgCOD/㎥.d was possible in both reactor. Total biomass amounts of pipe type was higher than gear type, however, attached biomass of gear type was higher than that of pipe type.

  • PDF

강변여과에 의한 이.취미 물질 제어 특성에 관한 타당성 연구 (A Feasibility study on Removal Characteristics of Taste and Odor using Bank Filtration Treatment)

  • 맹승규;박노석;임재림;김성수;정우창
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.307-317
    • /
    • 2010
  • This study was conducted in order to investigate bulk organic matter characteristics and behavior of geosmin and 2-methylisoborneol (2-MIB) during riverbank filtration, which are general surrogates of taste and odor in drinking water. Column studies were used to simulate bank filtration systems. Most of the aliphatic organic matter was removed effectively after soil passage, and it is believed to be polysaccharides according to LC-OCD and F-EEM analysises. Removal efficiencies of geosmin and 2-MIB within the filtration column reached above 95%. It was found that the removal of total dissolved organic matter has a correlation with that of geosmin and 2-MIB in the near of filtration surface (about 50cm).

칼슘과 마그네슘염을 이용한 염색폐수의 응집처리 (Treatment of Dyeing Wastewater by Flocculation with Calsium and Magnesium salts)

  • 김재용;서완주
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.89-98
    • /
    • 2002
  • The changes of conventional clarification process and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. The removal of waste matters such as SS, organic matter, color and turbidity contained in dyeing wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 84% of color in dyeing watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

칼슘과 마그네슘염을 이용한 축산폐수의 응집처리 (Treatment of stock wastewater by flocculation with Calsium and Magnesium salts)

  • 김재용
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.10-18
    • /
    • 2002
  • The changes of conventional clarification processe and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. In this context as new flocculation using calcium hydroxide and magnesum sulfate was carried out. The removal of waste matters such as SS, organic matter, COD, nitrogen and phosphorus contained in stock wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 60% of COD in stock watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

비분산 막-용매추출에 의한 유기오염물의 분리 (Separation of Organic Pollutants by Nondispersive Membrane-Solvent Extraction)

  • 유홍진;한성록
    • 한국산학기술학회논문지
    • /
    • 제5권2호
    • /
    • pp.174-185
    • /
    • 2004
  • 미세기공 중공사형 모듈을 이용한 비분산 막-용매 추출에 의하여 유기오염물을 페수로부터 분리하였다. 시스템은 향류 및 병류로 각각 진행되었으며, 분배계수의 비교로부터 MIBK가 분리용 용매로 선정되었다. 향류의 분리도가 병류보다 우수하였으며, 총괄물질전달계수도 구하였다.

  • PDF

DAF(Dissolved Air Flotation)를 이용한 정수처리에서 처리조건에 따른 VOCs(Volatile Organic Compounds)의 처리효율에 대한 연구 (Removal Rates of VOCs(Volatile Organic Compounds) for Treatment Condition using DAF(Dissolved Air Flotation) in Water Treatment)

  • 김미정;전세진
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.91-100
    • /
    • 1999
  • Treatment conditions of DAF(Dissolved Air Flotation) and removal rates of VOCs(Volatile Organic Compounds) in mixed water of H raw water and VOCs were investigated. The used VOCs were benzene, toluene, ethylbenzene, and xylene in aromatic compounds and iso propyl mereaptan, n-butyl mereaptan, dimethyl disulfide, and iso butyl mercaptan in odors. The related parameters include water type, treatment method, clay concentration, pH condition, flocculation time, flotation time, per-cent recycle, water temperature, pressure. The removal rates of VOCs were different on treatment process and water condition. Treatment time was longer, removal rates of VOCs was higher. Water temperature was more important than pressure in DAF parameters. Molecular weight was related with removal rate in several kinds of VOCs were decraesed by competition of each component in II raw water. When algac blooming D water was treated by DAF, TCOD(Total chemical Oxygen Demand) and chorophyll a was removed over 96%.

  • PDF