• 제목/요약/키워드: Optical therapy

검색결과 129건 처리시간 0.028초

마이크로LED를 응용한 차세대 생체 치료 소자 개발 (Next-Generation Biomedical Devices via MicroLEDs)

  • 이한얼
    • 한국전기전자재료학회논문지
    • /
    • 제34권4호
    • /
    • pp.221-228
    • /
    • 2021
  • With the advent of the IoT (internet of things) era, there has been discussion on how to efficiently use various information from daily life. In academic and industrial society, various smart devices such as smart watches, smart phones, and smart glasses have been developed and commercialized for narrowing the physical/psychological distance with user information. According to recent developments of smart devices, the contemporary people have desired to check their body information and treat disease by themselves. According to the needs of the time, biological researches by phototherapy/monitoring have been actively conducted. Among various light sources, microLEDs have been spotlighted due to their superior optoelectric properties and stability. In this paper, we would like to review the state-of-the research results on the next-generation biological therapy devices via microLEDs.

Polarization Spectral Imaging System for Quantitative Evaluation of Port Wine Stain Blanching Following Laser Treatment

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • 제7권4호
    • /
    • pp.234-239
    • /
    • 2003
  • Objective methods to assess quantitatively port wine stain (PWS) blanching in response to laser therapy are needed to improve laser therapeutic outcome. Previous studies have attempted to assess objectively PWS color based on point measurement devices. To date, these approaches have typically been limited by a number of factors such as small test area and need for contact. To address these issues, a polarization spectral imaging system and an image analysis method have been developed to evaluate quantitatively erythema and melanin content distribution in skin. The developed polarization spectral imaging system minimizes artifacts such as glaring, shadowing, and non-uniform illumination that interfere with image fidelity. Furthermore, the image analysis method has been employed to get images of skin melanin and erythema indices from the acquired color images for quantitative analysis. Finally, using PWS patient color image, the effectiveness in laser treatment of PWS was evaluated by calculating relative erythema index image that is the relative erythema index of PWS region to the normal region. The developed device and analysis method appears to be a simple and effective method for quantitative analysis of PWS blanching.

체외 상처 치유를 위한 4-채널 광 치료기 (4-channel Light Medical Therapy Apparatus for External Injury Cure)

  • 천민우;김성환;소금영;문영래;문성표;박용필;이호식;김태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

시기능 교정의 임상사례 (Case Study of Vision Therapy)

  • 박현주
    • 한국안광학회지
    • /
    • 제11권1호
    • /
    • pp.35-41
    • /
    • 2006
  • 양안시 이상의 문제를 연구하기 위하여 굴절 검사와 양안시 검사를 실시하였다. 조절과 양안시에 문제가 있는 대상자들은 굴절 이상 교정 외에도 다른 추가적인 처방이 필요하였다. 그 중 폭주 과다의 문제를 가지고 있는 2명의 대상자를 정하여 완전 교정된 안경, 또는 근방에서(+)ADD를 처방하고 4주 동안 시기능 훈련을 실시하였다. 4주 후 근업시 환자들의 불편감은 많이 해소되었으며, 타각적 검사 값들도 개선되었다. 임상에서 광학적 교정과 함께 시기능 훈련을 양안시 이상의 치료에 적극적으로 적용하고, 향후 연구를 통해 다양한 양안시 이상치료에 시도해도 좋은 결과가 있을 것으로 판단된다.

  • PDF

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

Vascular Morphometric Changes During Tumor Growth and Chemotherapy in a Murine Mammary Tumor Model Using OCT Angiography: a Preliminary Study

  • Kim, Hoonsup;Eom, Tae Joong;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.54-65
    • /
    • 2019
  • To develop a biomarker predicting tumor treatment efficacy is helpful to reduce time, medical expenditure, and efforts in oncology therapy. In clinics, microvessel density using immunohistochemistry has been proposed as an indicator that correlates with both tumor size and metastasis of cancer. In the preclinical study, we hypothesized that vascular morphometrics using optical coherence tomography angiography (OCTA) could be potential indicators to estimate the treatment efficacy of breast cancer. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber which was applied to a nude mouse, and the change in vascular morphology was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily OCTA maximum intensity projection map, multiple vessel parameters (vessel skeleton density, vessel diameter index, fractal dimension, and lacunarity) were compared with the tumor size in no tumor, treated tumor, and untreated tumor cases. Although each case has only one animal, we found that the vessel skeleton density (VSD), vessel diameter index and fractal dimension (FD) tended to be positively correlated with tumor size while lacunarity showed a partially negative correlation. Moreover, we observed that the changes in the VSD and FD are prior to the morphological change of the tumor. This feasibility study would be helpful in evaluating the tumor vascular response to treatment in preclinical settings.

심혈관계 질환의 줄기세포 치료에서 세포 추적 영상 (Tracking of Stem Cells for Treatment in Cardiovascular Disease)

  • 강원준
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.146-149
    • /
    • 2005
  • Various stem cells or progenitor cells are being used to treat cardiovascular disease in ischemic heart disease, stem ceil therapy is expected to regenerate damaged myocardium. To evaluate effects of stem cell treatment, the method to image stem cell location, distribution and differentiation is necessary. Optical imaging, MRI, nuclear imaging methods have been used for tracking stem cells. The methods and proglems of each imaging technique are reviewed.

치료용 고에너지 전자선 계측을 위한 광섬유 방사선 센서의 제작 및 특성 분석 (Fabrication and Characterization of a Fiber-Optic Radiation Sensor for High Energy Electron Beam Therapy)

  • 장경원;조동현;유욱재;이봉수;이정한;탁계래;조효성;김신
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.332-336
    • /
    • 2006
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator for high energy electron beam therapy. The intensities of scintillating light from a fiber-optic radiation sensor are measured with different field size, electron beam energy and monitor unit of a clinical linear accelerator. To obtain percent depth dose(PDD), the amount of scintillating light is measured at different depth of polymethylmethacrylate(PMMA) phantom. Also the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam and a subtraction method is investigated using a background optical fiber to remove a Cerenkov light.

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.