• 제목/요약/키워드: Optical distance indicator (ODI)

검색결과 3건 처리시간 0.018초

New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

  • Shandiz, Mahdi Heravian;Layen, Ghorban Safaeian;Anvari, Kazem;Khalilzadeh, Mohammadmahdi
    • Radiation Oncology Journal
    • /
    • 제33권1호
    • /
    • pp.42-49
    • /
    • 2015
  • Purpose: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. Materials and Methods: The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. Results: The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of $0.43^{\circ}$. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. Conclusion: The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작 (Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments)

  • 차동수;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발 (Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.109-113
    • /
    • 2002
  • 본 연구에서는 의료용선형가속기의 기기점검을 위한 일목요연하고 장기간의 통계처리가 가능한 새로운 정도관리 양식을 개발하였다. 개발된 양식을 2001년 8월부터 12월까지 국내의 6개의 기관에 적용하여 그 양식의 효율성을 평가하였다. 기존의 점검 양식은 단순히 선형가속기에 숫자로 표시되는 값들(digital data)과 측정장치를 이용하여 관찰된 값들(mechanical data)의 비교에 목적을 두고 있고, 각 항목들이 서술적으로 나열되어 있어 공간적으로 문제점을 파악하기 어렵다. 더욱이 기기의 장기간에 걸친 오차의 변화를 일목요연하게 알 수가 없다. 그러나 새로 개발된 점검 양식을 사용한다면, 디지털 데이터와 기계적 데이터의 비교는 물론 기기의 오차를 공간적으로 파악할 수 있게 될 것이다. 또한 기기의 장기간에 걸친 오차의 범위를 확인하게 되어 기기의 장기적 안정성을 알 수 있게 될 것이다. 뿐만 아니라 현실에 맞는 항목을 선택함으로써 기계적 정도관리(mechanical QA)를 수행하는 시간을 단축함과 동시에, 각 기관이 보유하고 있는 선형가속기의 장기간에 걸친 정도관리를 통해 얻은 데이터를 이용하여 치료장비의 오차에 대한 통계적, 물리적 데이터를 정도관리 직후 분석할 수 있게 되어 방사선 치료에 있어서 매우 중요한 요소인 방사선 치료장비의 기기적 정확성을 높일 수 있게 될 것이다.

  • PDF