• 제목/요약/키워드: Optical coherence tomography (OCT)

검색결과 140건 처리시간 0.026초

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제15권3호
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징 (Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model)

  • 박정은;;옥철호;김성원;이해영;박은기;정민정;권다영;;안예찬
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.1-6
    • /
    • 2020
  • 흉벽은 호흡을 통해 환경 입자의 직접적인 영향을 받는 기관으로 늑골, 흉막층, 늑간근으로 구성되어 있다. 흉벽의 질병을 조기에 진단하고 치료하기 위해서는 흉벽의 세세한 부분을 시각화하는 것이 중요하지만, 흉부 전산화 단층촬영이나 초음파로는 흉막층의 구조를 볼 수 없다. 반면, 고해상도의 광 결맞음 단층촬영법(optical coherence tomography, OCT)은 미세한 재료 중 하나인 탈크에 의한 흉막층의 반응을 관찰하는 데 적합하다. 그러나 빛세기 기반의 광 결맞음 단층촬영법은 흉벽의 세부 구조를 구별할 수 있는 정보를 제공하기에는 부족하여 탈크에 의한 흉벽의 반응과 근육의 변화를 각각 구별할 수 없다. 편광 민감 광 결맞음 단층촬영법(polarization-sensitive OCT, PS-OCT)은 광학적 복굴절을 가진 근육 등의 특정 조직들이 후방산란된 빛의 편광 상태를 변화시킨다는 점을 이용한다. 또한 근필라멘트의 배열과 관련된 근육의 복굴절은 지연 변화를 측정함으로써 근육 상태를 나타낸다. 편광 민감 광 결맞음 단층촬영 영상은 두꺼운 흉벽, 흉벽과 근육 간의 분리, 병변 주위의 위상 지연 측정의 세 가지 주요 관점에서 해석된다. 본 논문에서는 탈크 흉막유착술(pleurodesis)을 시행한 토끼의 흉벽을 편광 민감 광 결맞음 단층촬영법으로 연구하였다. 편광 민감 광 결맞음 단층촬영 영상은 각 층과 근육을 시각화하였다. 그리고 이 시스템은 정상과 손상된 병변의 복굴절 차이를 보여주었다. 또한, 위상 지연 기울기 기반 분석을 통해 편광 민감 광 결맞음 단층촬영 영상 및 조직학적 결과를 뒷받침하였다.

광간섭단층촬영술을 이용한 치아우식증의 발견 (Early caries detection using optical coherence tomography: a review of the literature)

  • 박영석;조병훈;이승표;손원준
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.367-376
    • /
    • 2011
  • 치아우식증의 조기 발견은 외과적 삭제를 피하면서, 적절한 치료를 할 수 있는 좋은 기회를 제공한다. 광간섭단층촬영술은 최근 각광받기 시작한 3차원 이미지 기술로서, 안과에서 광학적 생검의 목적으로 빈번히 이용되는 것을 필두로 다양한 의학 분야에 적용되어 왔고, 최근 초기 우식증의 발견에 전도유망하여 다양한 연구가 진행 중이다. 이 기술은 저 상관도 간섭계의 원리에 근거하고 있으며, 장점으로는 비침습적이고, 방사선을 사용하지 않으며, 3차원 이미지 구축이 가능하다는 점이다. 본 연구에서는 광간섭단층촬영술의 원리와 개략적인 개발 과정에 대한 기술과 함께 치아우식증에 관한 연구들에 대하여 고찰해 보았고, 이를 통해 이 기술의 응용 가능성을 확인하였다. 그럼에도 불구하고, 임상적인 유용성을 입증하기 위해서는 몇 가지 기술적 문제를 해결해야 하고, 보다 많은 생체 내 실험이 뒷받침되어야 할 것이다.

실시간 광단층 모니터링 안구 수술용 현미경 프로브 개발 (Development of The Intraoperative Surgical Optical Coherence Tomography Probe)

  • 김경운;이창호;정효상;한승훈;김홍균;김지현
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권2호
    • /
    • pp.53-58
    • /
    • 2012
  • Intraoperative surgical microscope is an essential surgical equipment. However, it has a restriction to classify the retina layers because of the contrast differences. To solve this problem, operators use surgical instrument such as an intraocular mirror. In this case, it has to amputate the patient's eye. In this study, we developed a probe the intraoperative surgical optical coherence tomography. We expect that the developed OCT probe can overcome the limit of OCT and be applied as a real-time surgical tool. In this paper, we demonstrate applicability of the probe through rabbit's experimentation.

Treatment of immune-mediated keratitis (IMMK) in dogs with immunosuppressants observed with spectral domain optical coherence tomography (SD-OCT)

  • Hyelin Kim ;Youngseok Jeong ;Eunji Lee;Kangmoon Seo ;Seonmi Kang
    • Journal of Veterinary Science
    • /
    • 제24권5호
    • /
    • pp.66.1-66.7
    • /
    • 2023
  • Two dogs presented with bilateral pattern-forming corneal opacity. Treatment with topical immunosuppressants was initiated after a complete ophthalmic examination. The response to treatment was assessed by analyzing serial images using slit-lamp biomicroscopy and spectral domain optical coherence tomography (SD-OCT). Both dogs responded to topical immunosuppressants; however, the lesions recurred once the treatment was abated or withdrawn. The most effective immunosuppressant in both dogs was 0.03% tacrolimus ointment. Early and continuous treatment with topical immunosuppressants may be necessary to improve corneal clarity and prevent scarring. SD-OCT could provide useful structural information regarding presumed immune-mediated keratitis and aid in monitoring treatment response.

고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징 (Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo)

  • 조한샘;장선주;오왕열
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.67-71
    • /
    • 2014
  • 혈관 내 OCT (optical coherence tomography) 는 혈관 벽 내부의 3차원적 미세구조를 영상화할 수 있어서 임상에서 각광을 받고 있다. 하지만 아직도 충분하지 못한 이미징 속도, 특히 내시경 프로브의 이미징 광 스캐닝 속도의 부족으로 혈관 길이 방향의 이미징 간격이 실제 시스템의 광학적 해상도보다 5배 이상 커서 혈관 종방향으로의 고해상도 이미징이 얻어지지 못하고 있는 상황이다. 본 논문에서는 초당 350장의 혈관 벽 단층 영상을 제공하는 고속 혈관 내 OCT 시스템을 기술한다. 본 시스템과 내시경 장치를 이용하여 47 mm 길이의 살아있는 토끼 대동맥을 3.7초만에 34 micron의 혈관 종방향 간격으로 얻는데 성공하였다. 34 micron의 종방향 간격은 실제 내시경의 그 방향 광학적 해상도와 비슷한 정도로서 3차원 모든 방향으로의 고해상도 이미징을 구현하였음을 보여준다. 얻어진 이미징 데이터의 3차원 영상 구현을 통해 혈관의 미세구조 및 이미징 전 삽입된 스텐트의 자세한 구조를 보였다.

In vivo Optical Coherence Tomography Imaging of the Mesothelium Using Developed Window Models

  • Ahn, Yeh-Chan;Chae, Yu-Gyeong;Hwang, Sang Seok;Chun, Bong-Kwon;Jung, Maan Hong;Nam, Sung Jin;Lee, Hae-Young;Chung, Jae Min;Oak, Chulho;Park, Eun-Kee
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.69-73
    • /
    • 2015
  • The mesothelium is an essential lining for maintaining the normal homeostasis of the closed body cavity and a central component of pathophysiologic processes. The mesothelium has been known as the end target for asbestos which induces asbestos-related lung diseases. Malignant mesothelioma (MM) is a rare and fatal neoplasm predominantly due to asbestos exposure. Adaptation of an advanced and reliable technology is necessary for early detection of MM because it is difficult to diagnose this disease in its early stages. Optical coherence tomography (OCT) provides cross-sectional images of micro-tissue structures with a resolution of $2-10{\mu}m$ that can image the mesothelium with a thickness of ${\sim}100{\mu}m$ and, therefore, enable investigation of early development of MM. The mesothelium is typically located at the pleura and tunica vaginalis of the scrotum. In this study, we developed animal window models in the above two anatomical sites to visualize mesothelial layers within the mesothelium. OCT images at the two locations were also acquired.

The Development of Double Clad Fiber and Double Clad Fiber Coupler for Fiber Based Biomedical Imaging Systems

  • Ryu, Seon-Young;Choi, Hae-Young;Ju, Myeong-Jin;Na, Ji-Hoon;Choi, Woo-June;Lee, Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.310-315
    • /
    • 2009
  • We report the fabrication of double clad fiber (DCF) and DCF coupler, suitable for fiber based imaging systems requiring the dual-channel transmission. Unlike the conventional DCF which uses silica for both cladding layers, the proposed DCF uses a low-index polymer for its outer-cladding layer coated over the conventional silica inner-cladding layer. The DCF is drawn with a conventional SMF preform but a low-index polymer coating is used for both jacket and outercladding of the fiber. To achieve the cladding mode coupling, a DCF coupler is fabricated by simply twisting two pieces of the proposed DCF after removing the polymer-coating at contacting regions. A cladding mode coupling ratio of 30% was achieved with a contact length of 16 cm. The proposed DCF and DCF coupler were employed in a composite optical coherence tomography (OCT) and fluorescence spectroscopy (FS) system, and both OCT images and FS signal from a plant tissue are measured simultaneously.

고방(古方)을 통한 급성 폐쇄성 녹내장의 한방치험 1례 (A Case Report of Acute Angle Closure Glaucoma Patient Treated with Go-bang)

  • 한기은;강은정
    • 대한한의학회지
    • /
    • 제44권2호
    • /
    • pp.170-180
    • /
    • 2023
  • Objectives: This is a case report on the treatment of one patient with acute angle-closure glaucoma using traditional Korean medicine. Methode: We assessed the progression of acute angle-closure glaucoma by analyzing Optical Coherence Tomography(OCT) results. Results: Acute angle closure glaucoma did not progress to OCT after treatment. Conculsion: We obtained results from OCT examinations indicating that the progression of acute angle-closure glaucoma had ceased after Korean herbal medicine treatment.