• 제목/요약/키워드: Optical coherence tomography (OCT)

검색결과 140건 처리시간 0.028초

Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현 (2-D OCT image implementation using low coherence SLD)

  • 정태호;박양하;오상기;김용평
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

피부결 및 주름 평가에 있어 광학단층영상술(Optical Coherence Tomography, OCT) 활용 연구(Pilot Study) (Evaluation of Skin Texture and Wrinkle Using Optical Coherence Tomography (Pilot Study))

  • 김승훈;안유진;;김필운;정웅규;이해광
    • 대한화장품학회지
    • /
    • 제43권3호
    • /
    • pp.247-254
    • /
    • 2017
  • Optical Coherence Tomography (OCT)는 광 산란과 간섭 현상을 이용하여 비침습적으로 생체조직의 표면 및 내부 구조를 이미지화 할 수 있는 영상기술이다. OCT 기술은 질병의 조기진단과 같은 의료 분야에서 활발히 활용되어 왔으나 미용을 위한 피부진단으로의 적용은 아직 초기단계라 할 수 있다. 본 연구에서는 OCT를 피부효능평가에 도입하여 피부결 및 주름 평가에 활용 가능성을 살펴보았다. 모사판(replica)을 대상으로 한 평가에서 PRIMOS와 유사한 패턴을 보여 주었고 주름을 모사한 3차원 모델을 이용한 평가에서는 PRIMOS에 비해 측정각에 따른 오차가 적음을 확인할 수 있었다. 그리고 커버력 화장품을 이용한 사용 전후의 평가에 있어서도 이를 구분할 정도의 해상도를 보였다. 이러한 평가를 통해 OCT의 미세주름평가에서의 가능성을 알 수 있었고 향후 더 구체화된 연구를 통해 그 활용가능성에 대한 신뢰도를 높일 예정이다.

정현파로 구동되는 PZT 광경로 지연기를 이용한 광 간섭 단층촬영시스템 (Optical Coherence Tomography with Sinusoidal-Wave Drive an Optical Delay Line using Piezoelectrics Strecher)

  • 김영관;김용평
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.274-279
    • /
    • 2007
  • 광간섭 단층촬영(OCT)용으로 원통형 압전소자(PZT)와 단일모드 광섬유를 이용한 광경로 지연기를 제작하여 정현파로 구동하고 특성을 분석하였다. 제작한 OCT 시스템은 검침단과 기준단을 대칭 구동하는 이중 광경로 지연방식을 사용하였다. 정현파 구동을 통한 PZT 광경로 지연 방식은 삼각파 구동과 비교하여 입력파형의 첨두 부분에서의 비선형현상을 제거하여 높은 반복성을 나타냄을 보였고, 삼각파 구동으로는 불가능했던 부분을 영상화 할 수 있었다.

광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구 (Video Rate Image Signal Processing for Optical Coherence Tomography)

  • 나지훈;이병하;이창수
    • 제어로봇시스템학회논문지
    • /
    • 제10권3호
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Optical Coherence Tomography를 이용한 원발성 맥락망막염 이환견의 진단 및 치료 (The Diagnosis and Treatment of Primary Chorioretinitis using Optical Coherence Tomography in a Dog)

  • 지동범;유석종;서강문;정만복
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.324-328
    • /
    • 2013
  • A 5-year-old intact male Yorkshire terrier dog was referred with a 1-week history of blindness. In both eyes, menace responses and pupillary light reflexes were absent. The indirect ophthalmoloscopy revealed multiple small gray-white and discoloration lesion in mid-nontapetum area in both eyes. Electroretinograms showed diminished amplitude of a- and b-waves. Multifocal serous retinal detachments were detected with optical coherence tomography (OCT) over the small gray-white and discoloration lesion in the fundus. After one week of treatments, the indirect ophthalmoloscopy showed that irregular patches and hyperpigmentation in the center of hyperreflectivity area. Reattachment and retinal thinning were observed by the OCT. The results indicate that OCT scanning is considered to be a useful method for retinal evaluation in dogs with chorioretinitis.

표면 추적 알고리즘을 적용한 공통경로 FD-OCT의 성능개선 (Enhancement of Common-path Fourier-domain Optical Coherence Tomography using Active Surface Tracking Algorithm)

  • 김민호;김거식;송철규
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.639-642
    • /
    • 2012
  • Optical coherence tomography(OCT) can provide real-time and non-invasive subsurface imaging with ultra-high resolution of micrometer scale. However, conventional OCT systems generally have a limited imaging depth range within a depth of only 1-2 mm. To overcome the limitation, we have proposed an active surface tracking algorithm used in common-path Fourier-domain OCT system in order to extend the imaging depth range. The surface tracking algorithm based on the threshold and Savitzky-Golay filter of A-scan data was applied to real-time tracking. The algorithm has controlled a moving stage according to the sample's surface variance in real time. An OCT image obtained by the algorithm clearly show an extended imaging depth range. Consequently, the proposed algorithm demonstrated the potential for improving the conventional OCT systems with limitary depth range.

심혈관 OCT의 임상적 응용 (Clinical Applications of Intracoronary OCT (Invited Paper))

  • 하진용;김중선;홍명기
    • 한국광학회지
    • /
    • 제26권1호
    • /
    • pp.1-8
    • /
    • 2015
  • 심혈관 질환은 심장마비의 가장 흔한 원인으로 관상동맥의 협착으로 심근에 산소와 영양분을 제대로 공급하지 못하게 되어 발생하게 된다. 이를 내과적으로 치료하기 위해 심혈관 중재술이 시행되는데 이때 스텐트 삽입 여부, 위치, 크기, 그리고 스텐트 삽입 후 혈관벽과의 밀착 여부를 평가하기 위해 혈관 내 광간섭단층촬영(OCT, optical coherence tomography) 내시경 진단검사를 시행한다. 본 논문에서는 이러한 심혈관 OCT 원리와 기술 동향, 그리고 실제 의료현장에서 심혈관 OCT의 임상적 응용 및 활용가치를 소개하고자 한다.

Ocular coherence tomography를 이용한 개의 망막변성증 평가 (Assessment of retinal degeneration with optical coherence tomography in a dog)

  • 지동범;유석종;서강문;정만복
    • 대한수의학회지
    • /
    • 제53권2호
    • /
    • pp.137-141
    • /
    • 2013
  • To report retinal image of in a 6-year-old male castrated poodle dog with a 2-month history of nyctalopia using optical coherence tomography (OCT). Ocular reflexes were present in both eyes and slit lamp examination showed anterior subscapular cataract in the right eye. There were fundus abnormalities in both eyes similar to retinal degeneration. Scotopic electroretinograms (ERGs) revealed significantly subabnormal amplitudes and prolonged implicit time, whereas photopic ERGs were better maintained, although far from normal. OCT of affected dogs revealed generalized retinal thinning much more than a normal age-matched dog. Therefore, OCT scanning is considered to be a useful method for retinal evaluation in dogs with retinal degeneration.

간섭계 형태에 따른 광단층 촬영장치의 SNR 비교 (Comparison of Signal to Noise Ratios in different configulation of optical coherence tomography systems)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.804-806
    • /
    • 2004
  • 인체에 무해하며 고분해능의 단층영상과 저가격 및 소형으로 제작이 가능하여 전세계적으로 많은 연구가 진행중인 광영상 단층촬영기(Optical coherence tomography system : OCT)에 관한 것이다. 샘플에서 흡수와 산란으로 인하여 샘플로부터 반사된 광신호는 매우 미약하다. 게다가 커플러등에 의한 손실로 인하여 광검출기에 도달하는 신호는 매우 미약하다. 이러한 On시스템의 신호대 잡음비를 향상시키기 위하여 기본적인 마이켈슨 간섭계와 마흐젠더 간섭계를 구성하여 시뮬레이션과 기준샘플을 이용하여 측정하였다. 실험결과 마흐젠더 간섭계를 사용한 샘플로 반사된 광신호는 OCT 시스템의 신호대 잡음비 향상시키기 위하여 두 가지 형태의 간섭계를 구성하였으며 시뮬레이션을 통한 비교 분석과 기준 샘플의 측정에 의한 비교분석을 하였다. 실험결과 마흐젠더 간섭계형 OCT 시스템이 신호대 잡음비가 향상됨을 확인 하였다.

  • PDF

Optimized Working Distance of a Micro-optic OCT Imaging Probe

  • Kim, Da-Seul;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.330-335
    • /
    • 2020
  • We have investigated optimization of the working distance (WD) for a highly miniaturized imaging probe for endoscopic optical coherence tomography (OCT). The WD is the axial distance from the distal end of the imaging probe to its beam focus, which is demanded for dimensional margins of protective structures, operational safety, or full utilization of the axial imaging range of OCT. With an objective lens smaller than a few hundred micrometers in diameter, a micro-optic imaging probe naturally exhibits a very short WD due to the down-scaled optical structure. For a maximized WD careful design is required with the optical aperture of the objective lens optimally filled by the incident beam. The diffraction-involved effect was taken into account in our analysis of the apertured beam. In this study, we developed a simple design formula on the maximum achievable WD based on our diffraction simulation. It was found that the maximum WD is proportional to the aperture size squared. In experiment, we designed and fabricated very compact OCT probes with long WDs. Our 165-㎛-thick fiber-optic probes provided WDs of 3 mm or longer w ith reasonable OCT imaging performance.