• Title/Summary/Keyword: Optical coherence

Search Result 341, Processing Time 0.033 seconds

Comparison of Signal to Noise Ratios in different configulation of optical coherence tomography systems (간섭계 형태에 따른 광단층 촬영장치의 SNR 비교)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.804-806
    • /
    • 2004
  • As a noninvasive imaging meathod, optical coherence tomography system has been extensively studied because it has some advantage such as imaging of high resolution, low cost, and compace size configuration. The optical power of the sample signal reflected from an object is usually very small in optical coherence tomography(OCT) due to absorption and scattering in a sample material. Furthermore, there happens a serious loss of sample signal power in a fiber coupler because it does not transfer to a photodetector but return to the optical source. In order to improve the SNR of OCT system, basic Michelson and Mach-Zehnder interferometer types were configured then, we compared simulation with measurement of reference sample Therefore, an On in configuration of Math-Zehnder interferometer was demonstrated in order to improve the signal to noise ratio

  • PDF

Depth-resolved Stokes parameters of light backscattered from turbid media with polarization-sensitive optical coherence tomography system and successive phase-shifting algorithm (위상천이원리 와 PS-OCT시스템을 적용한 역산란광의 매질 깊이별 스톡스변수 추출)

  • Oh, Jung-Taek;Kim, Seung-Woo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.286-287
    • /
    • 2003
  • Polarization-sensitive optical coherence tomography (PS-OCT) was developed to image highly scattering tissues with accounting for polarization effects in the sample. These polarization-sensitive images can provide additional information on the structure of the tissue because of a polarization state of the light is changed at its interaction with biological tissues. The scattering and birefringence are two phenomena, which change the polarization state of light passing through medium. (omitted)

  • PDF

Dark Resonance and Its Potential Applications: High-Resolution Spectroscopy

  • Ham, Byoung-Seung
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.110-116
    • /
    • 2001
  • Recently observed dark resonance phenomena is solids are reviewed and discussed for potential applications to high-resolution coherence spectroscopy. in an inhomogeneously broadened system, a new type of high-resolution spectroscopy based on electromagnetically induced transparency is demonstrated.

Analytic study on the realization of partially coherent Gaussian Schell-model beams with isotropic cross section and anisotropic degree of coherence function (등방성 빔 단면과 비등방성 공간 부분 코히어런스 특성을 갖는 가우시안 셀 모델 빔의 구현에 대한 해석적 연구)

  • Kim, Hwi;Kim, Tae-Soo;Choi, Kyung-Sik;Lee, Byung-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.200-213
    • /
    • 2004
  • The realization of partially coherent Gaussian Schell-model beams with isotropic cross section and anisotropic degree of coherence function is investigated theoretically. An optical system is devised to transform diffused light generated by passing the Gaussian beam of the He-Ne laser thorough a rotating holographic diffuser to the partially coherent Gaussian Schell-model beam with isotropic cross section and anisotropic degree of coherence function. Analytic design equations are formulated and design examples are presented.

The Identification of Vibration Sources in Optical Disk Drive Using PCF Method (PCF 기법을 이용한 광디스크 드라이브의 진동원 규명)

  • 함경훈;장영배;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.127-133
    • /
    • 2002
  • After the vibration source is searched in optical disk drive as an information storage device broadly used the influence of it against FES(Focusing Error Signal) which is a kind of positioning error of pick up from the circuit is carefully examined. For that Purpose, partial coherence function method is applied on a simple multi-degree of freedom model made for the theoretical verification and it is practically introduced in optical disk drive for analyzing the effect of vibration source. Finally, partial coherence output spectrum is attentively observed in order to know which vibration source is a great influence on FES.

  • PDF

Realization of Swept Source-Optical Coherence Tomography using FDML Laser (FDML 방식 스위핑 광원을 사용한 SS-OCT 구현)

  • Eom, Jin-Seob
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • In this paper, the swept source-optical coherence tomography system using frequency domain mode locked(FDML) laser has realized. The FDML swept source laser showed 55.03 kHz sweeping speed, 125 nm sweeping range, and 9 mW output optical power, which are the superiority of FDML laser compared to previous swept source lasers. Also, through the cross-sectional image captured at 5 frames per second for a mirror, a 1 mm-thickness glass plate, and a thumb bottom, the performance of the system has demonstrated.

Partial Spectrum Detection and Super-Gaussian Window Function for Ultrahigh-resolution Spectral-domain Optical Coherence Tomography with a Linear-k Spectrometer

  • Hyun-Ji, Lee;Sang-Won, Lee
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.73-82
    • /
    • 2023
  • In this study, we demonstrate ultrahigh-resolution spectral-domain optical coherence tomography with a 200-kHz line rate using a superluminescent diode with a -3-dB bandwidth of 100 nm at 849 nm. To increase the line rate, a subset of the total number of camera pixels is used. In addition, a partial-spectrum detection method is used to obtain OCT images within an imaging depth of 2.1 mm while maintaining ultrahigh axial resolution. The partially detected spectrum has a flat-topped intensity profile, and side lobes occur after fast Fourier transformation. Consequently, we propose and apply the super-Gaussian window function as a new window function, to reduce the side lobes and obtain a result that is close to that of the axial-resolution condition with no window function applied. Upon application of the super-Gaussian window function, the result is close to the ultrahigh axial resolution of 4.2 ㎛ in air, corresponding to 3.1 ㎛ in tissue (n = 1.35).