• Title/Summary/Keyword: Optical Tomography

Search Result 303, Processing Time 0.025 seconds

Development of a Ultra Broadband Optical Coupler Based on a Photonic Crsytal Fiber (광자결정 광섬유기반 광신호 분배기 개발)

  • Yoon, Min-Seok;Lee, Sang-Bae;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.195-199
    • /
    • 2010
  • A broadband optical coupler with a broad bandwidth of 1000 nm based on a photonic crystal fiber (PCF) is investigated. The PCF has 6 layers of air hole structures and a diameter of $130{\mu}m$. The PCF-based coupler is fabricated by using a fused biconical tapering method based on heating and elongation processes. Changing temperature and an elongation length can control the bandwidth and the bandedge wavelength of the PCF-based broadband coupler. The diameter of the fused region in the PCF-based coupler was measured to be $23{\mu}m$. The fabricated PCF-based coupler has a nearly-flat coupling ration of 3-dB in a broad bandwidth of 1000 nm, which is wider than that of the previously reported PCF-based coupler and that of the single-modefiber-based coupler. Since the resolution of optical coherence tomography system is proportional to the bandwidths of both an optical light sources and an interferometer, the fabricated PCF-based broadband optical coupler has a great potential for realization of a broadband interferogram.

Analysis of the Scattering Coefficients of Microspheres Using Spectroscopic Optical Coherence Tomography

  • Song, Woosub;Lee, Seung Seok;Lee, Byeong-il;Choi, Eun Seo
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.278-288
    • /
    • 2021
  • We propose a characterization method for the scattering property of microspheres using spectroscopic optical coherence tomography (OCT). To prove the effectiveness of the proposed method, we prepare solutions of different concentrations using microspheres ranging from 28 to 2300 nm in diameter. Time-frequency analysis is performed on the measured interference spectrum of each solution, and the resulting spectroscopic information is converted into histograms for centroid wavelengths. The histograms present a very sensitive response to changes in the concentration and size of microspheres. We classify them into three categories according to their characteristics. When the histogram of each category is replaced with the corresponding calculated value of the scattering coefficient, each category is mapped to a different scattering-coefficient region. It is expected that the proposed method could be used to investigate the optical characteristics of a biological sample from OCT images, which would be helpful for optical diagnostic and therapeutic applications.

K-domain Linearization Using Fiber Bragg Grating Array Based on Fourier Domain Optical Coherence Tomography (광섬유 브라그 격자를 이용한 퓨리어 영역 광 결맞음 단층 촬영에서의 파수영역 선형화)

  • Lee, Byoung-Chang;Eom, Tae-Joong;Jeon, Min-Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.72-76
    • /
    • 2011
  • We demonstrate a k-domain linearization using a fiber Bragg grating (FBG) array for Fourier domain optical coherence tomography based on a wavelength swept laser. The k-domain linearization is carried out with an interpolation method using a FBG array with five FBGs. The measured signal-to-noise ratio from the point spread function after k-domain linearization is 12 dB improved over that of without k-domain linearization at the 1 mm depth of the sample. Clear OCT imaging of the slide glass with k-domain linearization could be obtained.

Study of Optical Tomography for Measurement of Spray Characteristics at High Ambient Pressure (고압 환경에서의 분무 특성 계측을 위한 광학 토모그래피 기법 연구)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Choi, Ho-Yeon;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.36-44
    • /
    • 2009
  • Spray cross-section was measured by the Optical Line Patternator (OLP) and Optical Tomography at high ambient pressure. The laser line beam passed through the spray region, then Mie scattered signal and transmitted light were captured. The measured signal was processed to obtain a distribution of attenuation coefficient in spray cross-section. Beer-Lambert's law and mathematical reconstruction methods were used to reconstruct the distribution of attenuation coefficient. Spray became dense at high pressure and attenuation of scattered signal occurred seriously. OLP method, which uses Mie scattered signal, showed limit in compensating attenuation problem in dense spray region. Optical tomography reconstructed spray cross-section well, from transmission rate of light penetrating spray region.

High-resolution imaging of microneedles in biological tissue with optical coherence tomography (광간섭 단층 영상기술을 이용한 생체 내 microneedle 삽입 구조 영상)

  • Kim, Hun;Heo, Jung;Lee, Kang Ju;Ryu, Su Ho;Ryu, Won Hyoung;Joo, Chulmin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2013
  • Optical coherence tomography (OCT) allows non-invasive, cross-sectional optical imaging of biological tissue with high spatial resolution and acquisition speed. In principle, it is analogous to ultrasound imaging, but uses near-infrared light instead of ultrasound, measuring the time-delay of back-scattered light from within biological tissue. Compared to ultrasound imaging, it exhibits superior spatial resolution (1~10 um) and high sensitivity. Therefore, OCT has been applied to a wide range of applications such as cellular imaging, ophthalmology and cardiology. Here, we describe a novel application of OCT technology in visualizing microneedles embedded in tissue that is developed to deliver drugs into the dermis without the injection mark in the human skin. Detailed three-dimensional structural images of microneedles and biological tissues were obtained. Examining structural modification of microneedles and tissues during insertion process would enable to evaluate performance of various types of microneedles in situ.