• Title/Summary/Keyword: Optic microscope

Search Result 48, Processing Time 0.029 seconds

A Comparative study on Characteristic of Ginseng Radix in Korea and China (한국삼(韓國蔘)과 중국삼(中國蔘)의 품질 비교 연구)

  • Song, Ho-Joon
    • The Korea Journal of Herbology
    • /
    • v.25 no.3
    • /
    • pp.61-64
    • /
    • 2010
  • Objctive:To clarify the criterion, the characteristic of varaious age of ginseng radix cultivated in Korea and China were studied. Method:The surface of the transverse section of the specimen was made into a slid by the Paraffin Section method, and then dyed by Safranine Malachite Green method. The samples were observed at the power of 400 by an optic microscope(Olympus, Japan). The component and flavor of ginseng radix were analyzed by TLC(Thinlayer Chromatography) and electronic nose(FOX3000, France). Result:Ginseng radix according to the growing district and various age were comparative analyzed by optic microscope, TLC and electronic nose. The results were as followings. 1. The external form of Korean ginseng is longer and brightness then Chinese ginseng. 2. The internal form of Korean and Chinese ginseng are similar to each other. 3. The component of Korean and Chinese ginseng in TLC are similar to each other. 4. The fragrance of Korean and Chinese ginseng are clearly different. Conclusion:The results in this study demonstrate that morphology and component of Korean ginseng are similar to Chinese, on the other hand, fragrance of Korean and Chinese ginseng are different.

Controller Design for Electron Beam Manufacturing System (전자빔 가공기의 제어기 구성)

  • Lim, S.J.;Kang J.H.;Lee C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1862-1865
    • /
    • 2005
  • We have a plan to design a controller for electron beam manufacturing system. At first, we designed a controller for SEM. The controller consists of five parts (power source, beam controller, scanning controller, optic controller and main controller). Beam controller supplies pulse wave for generating high voltage and can monitor the status of high voltage instrument through emission current. Optic controller controls focus, spot size and image shift. Main controller transmits variables from operating program to each part and monitors the status of peripheral device.

  • PDF

Hardware Design for the Control Signal Generation of Electron Optic by Focal Length (Focal length에 의한 전자 렌즈의 제어 신호 생성을 위한 하드웨어 설계)

  • Lim, Sun-Jong;Lee, Chan-Hong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.96-100
    • /
    • 2007
  • Condenser lens and objective lens are used to demagnify the image of the crossover to the final spot size. In lens, electrons are focused by magnetic fields. This fields is fringing field. It is important in electron focusing. Electron focusing occurs the radial component field and axial component field. Radial component produces rotational force and axial component produces radial force. Radial force causes the electron's trajectory to curve toward the optic axis and corss it. Focal length decreases as the current of lens increases. In this paper, we use the focal length for desiging the hardware of lens current control and present the results.

Dysfunction of Retinal Cell and Optic Nerve by Continuous Cerebroventricular Infusion of Glucosamine

  • Jang, So-Yong;Han, Inn-Oc;Jun, Gyo;Oh, Sei-Kwan
    • Biomolecules & Therapeutics
    • /
    • v.17 no.4
    • /
    • pp.362-369
    • /
    • 2009
  • We have investigated the effect of glucosamine on the retinal cells after continuous infusion into cerebroventricle by using osmotic minipump to avoid peripheral effect. Continuous intracerebroventricular (i.c.v) infusion of glucosamine with the rate of 0.1 ${\mu}mol$/10 ${\mu}l$/hr for 7 days resulted in morphological changes of the optic nerve in electron microscopic level as well as morphological changes of the retina in light microscopic level. Retinal sections were immunostained for the detection of morphological changes of astrocytes. GFAP immunoreactivity appeared not only in the Muller cells but also many of the radial processes of Muller cells. The optic nerve showed deformed axon and slight lamellar separation of myelin sheath after continuous infusion of glucosamine in observing with electron microscope. Interestingly, vacuoles were observed in deformed axons and retinal layers were folded and detached. These results suggested that glucosamine plays a role in induction of morphological dysfunction in retina and optic nerves.

Physical Properties of E-glass Fiber According to Fiberizing Temperature (섬유화 온도 변화에 따른 E-glass fiber의 물리적 특성)

  • Lee, Ji-Sun;Lee, MiJai;Lim, Tae-Young;Lee, Youngjin;Jeon, Dae-Woo;Hyun, Soong-Keun;Kim, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.27 no.1
    • /
    • pp.43-47
    • /
    • 2017
  • E (Electric) -glass fibers are the most widely used glass fibers, taking up 90 % of the long glass fiber market. However, very few papers have appeared on the physical characteristics of E-glass fibers and how they depend on the fiberizing temperature of fiber spinning. Glass fiber was fabricated via continuous spinning process using bulk E-glass. In order to fabricate the E-glass specimen, raw materials were put into a Pt crucible and melted at $1550^{\circ}C$ for 2hrs; mixture was then annealed at $621{\pm}10^{\circ}C$ for 2hrs. The transmittance and adaptable temperature for spinning of the bulk marble glass were characterized using a UV-visible spectrometer and a viscometer. Continuous spinning was carried out using direct melting spinning equipment as a function of the fiberizing temperature in the range of $1175{\sim}1250^{\circ}C$, while the winder speed was fixed at 500 rpm. Subsequently we investigated the physical properties of the E-glass fiber. The average diameter of the synthesized glass fiber was measured by optical microscope. The mechanical properties of the fiber were confirmed using a UTM (universal materials testing machine); the maximum tensile strength was measured and found to be $1843{\pm}449MPa$ at $1225^{\circ}C$.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Fabrication of super hydrophilic TiO2 thin film by a liquid phase deposition (액상증착법에 의한 초친수 TiO2 박막 제조)

  • Jung, Hyun-Ho;Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Choi, Duk-Gun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.227-231
    • /
    • 2010
  • Super hydrophilic $TiO_2$ thin films with photocatalytic property were successfully fabricated on a glass substrate by liquid phase deposition (LPD). The $TiO_2$ thin film formed nano particles on a surface at $70^{\circ}C$. As an immersion time in $TiF_4$ solution increased, the thickness of thin films gradually increased. $TiO_2$ thin film showed a water contact angel of below ca. $5^{\circ}$ and the transmittance of ca. 75~90 % in visible range. In addition, $TiO_2$ thin film showed the photocatalytic property to decompose methyl orange solution by the illumination of UV light. The surface morphologies, optical properties and contact angel of prepared thin films with a different immersion time were measured by field emission scanning electron microscope (FE-SEM), atomic force microscope (AFM), UV-Vis spectrophotometer and contact angle meter.

Polarization-independent temperature sensor using cladding layers of the overlay waveguide coupled with a side-polished fiber (측면 연마 광섬유와 결합된 상부 도파로의 클래딩을 이용한 편광 무의존 온도센서)

  • 손경락;김광택;송재원
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.467-472
    • /
    • 2002
  • In this paper, we propose a polarization-insensitive temperature sensor using a thermo-optic effect of the upper and (or) lower cladding of a planar waveguide in contact with a side-polished fiber. A microscope cover glass with thickness of a 170 ${\mu}{\textrm}{m}$ is adopted as an overlay waveguide because this waveguide opposes sudden temperature change and ensures polarization-insensitive responses. The measured polarization-dependence loss is less than 0.3 dB. The temperature can be detected as a result of the shift in coupling wavelength of the sensor. We investigate the shift in coupling wavelength as a function of the temperature variation with respect to the different thermo-optic coefficients of lower and upper claddings. We also show that the temperature sensitivity of the device can be easily controlled by the thermo-optic coefficients of lower and upper claddings of the overlay waveguide.

Orientational deformation of ferroelectric liquid crystal molecules by bending performance of plastic substrate

  • Son, Ock-Soo;Lee, Ji-Hoon;Jang, Chi-Woong;Lim, Tong-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.338-341
    • /
    • 2005
  • We have examined the aspects of the orientational ordering deformation of ferroelectric liquid crystal during bending performance of plastic substrate by analyzing the polarizing optical microscope texture and the birefringence of the cell. Striped texture becomes more prominent as the radius of curvature of substrate gets smaller. The optic axis of the adjacent stripes domain was not same and the relative angle between them becomes larger as the radius of curvature gets smaller. Especially, the optic axis rotation angle of one domain was lager than the other and the liquid crystal molecules in each domain became more coherent. In addition, the birefringence data with obliquely incident light shows the polar direction shift of liquid crystal molecule by bending performance.

  • PDF