• Title/Summary/Keyword: Optic lens

Search Result 100, Processing Time 0.021 seconds

Analysis of Assembling Tolerance of Optical Components in NFR System (NFR 시스템 헤드의 광 부품 조립 정밀도 분석)

  • 오형렬;권대갑;이준희;윤형길;김진용;김수경;김영식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.718-721
    • /
    • 2001
  • For higher recording density in optical data storage, near field optics is being actively researched as one of the promising alternatives. But the tight assembling tolerance in NFR is one of big barriers to overcome for the realization of it. In this paper, the tolerances in assembling optic components of NFR system are analyzed. Some of key tolerances can be loosened by the optimization of objective lens design. But one of them become too tight by the optimization and should be controlled by other means. One of possible methods to control the tolerance is discussed.

  • PDF

Investigation of Research & Development Trends for Sunlight System (태양광 채광 시스템의 기술개발동향에 관한 조사분석연구)

  • Kim, Sun-Ho;Yoon, Kwang-Sik;Kim, Byung-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.260-263
    • /
    • 2007
  • The importance of natural light in building is known by all of us who experienced dark rooms. The sunlight system is very important from energy saving and human welfare point of view. The system consists of light-collecting module, light -transporting module and light-emitting module. The light-collection is used light reflection mirror, a prism for lighting bent, and lens for light condensing. The transportation of collected sunlight is used polished duct, tube, pipe and specially used fiber optic cable. This paper investigate research and development trends of sunlight system for advanced product.

  • PDF

THE DESIGN OF QUASI-OPTICS FOR DUAL-CHANNEL SIS RECEIVER (100GHz/150GHz 대역용 이중채널 SIS수신기의 준광학계 설계)

  • 박종애;한석태;김광동;김효령;정현수;김태성;이창훈;조세형;양종만
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.67-79
    • /
    • 1997
  • We have designed the quasi optics of the dual channel receiver to observe the radio sources with 100GHz-band and 150GHz-band simultaneously. We introduced the general quasi optics and the relation between the Gaussian beam and thin lens approximation. We determined the parameters of the quasi optic components to match the beam waist at cassegrain focus with that of feed horn well.

  • PDF

A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array (UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구)

  • Choi, Myeong-Il;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

AOD-based Angular Multiplexing in Volume Holographic Memory System (체적 홀로그래픽 메모리 시스템에서 AOD를 이용한 각다중화)

  • 문홍섭;길상근;김은수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.92-98
    • /
    • 1998
  • In this paper, we implemented an angularly multiplexed volume holographic memory system using an AOD that is controlled electronically, with rapid access time(10$mutextrm{s}$) and accurate repeatability of the reference beam. First we designed an AOD-based angular multiplexing system without the frequency compensation of the object beam, and magnified the deflection angle of AOD through the combination of lens so that we increased the storage capacity up to six times. Finally fifty-one images were stored experimentally in a photorefractive material of 1㎤ Fe:LiNbO$_3$.

  • PDF

Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air (오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성)

  • Pang, Man-Sik;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.

A comprehensive comparison of IMRT and VMAT plan quality for orbital lymphoma (안와 림프종 환자의 방사선치료를 위한 세기조절방사선치료와 용적세기조절회전치료의 전산화 치료계획에 대한 고찰)

  • Yoo, Soon Mi;Ban, Tae Joon;Yun, In Ha;Baek, Geum Mun;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.281-287
    • /
    • 2014
  • Purpose : The purpose of this study is to compare the plan quality of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of orbital lymphoma. IMRT, partial single arc(SA) and partial-double arc(DA) VMAT plans for four patients with orbital lymphoma treated at our institution were used for this study. Conformity Index(CI), Paddick's Conformity Index(PCI) and Homogeneity Index(HI) of planning target volume(PTV) were used to evaluate dosimetric quality of each plan. The Monitor Unit (MU), treatment time and dose of ipsilateral lens from each type of plan were measured for comparison. Materials and Methods : The CI of PTV for IMRT, SA and DA were measured as 0.88, 0.86, 0.92. The PCI of DA was the lowest as 1.33. Also HI of DA was the lowest in measured plans as 1.15. Mean dose of lens, lacrimal gland, optic chiasm, the opposite optic nerve and both orbit was analyzed with V30, V20, V10, V5. The result showed that the lowest dose in IMRT highest in SA in opposite lens, lacrimal gland, optic nerve, orbit. Results : Treatment time and average MU of IMRT was about three times higher than SA. Conclusion : Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating orbital lymphoma.

A Study on the Lighting Distribution Optimal Design of 250 W LED Streetlight (250 W급 LED가로등의 배광 최적설계에 관한 연구)

  • Shin, Wang-Soo;Lee, Seung-Min;Gwon, Young-Guk;Lee, Jin-Youle;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.408-413
    • /
    • 2015
  • Road lighting has emerged in importance as an essential system to secure safety and visibility for drivers and pedestrians. According to the Road Lighting Standards (KS A 3701), the luminance uniformity (U0) should be 0.4, the luminance uniformity for lanes (UI) should be 0.5, and a threshold increment (TI) of 10% should be satisfied. In this study, we conducted simulations using the Relux program in which the secondary optical lens was applied to a 21 W engine. Ten LED engines were installed on a two-way four-lane road, and the simulation result satisfied the requirements with U0 0.47, UI 0.63 and TI 8%. The U0, UI, and TI were compared with the angle of the LED streetlight varied in the range of $9^{\circ}{\sim}15^{\circ}$ with $0.5^{\circ}$ intervals. The range was selected as ${\pm}25%$ of the standard inclination angle of $12^{\circ}$ according to the Road Lighting Standard. The U0 was high and the UI and TI were low when the tilting angle was in the range of $9.5^{\circ}{\sim}10.5^{\circ}$. Consequently, an optimum-design of lighting distribution was obtained for the concrete two-way four-lane road when the inclination angle was $9^{\circ}$.

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.

Manufacturing and Characteristic Evaluation of Free space Optical Communication Devices in 5G Mobile Base Stations for Emergency Disaster Response (긴급재난 대응용 5G 이동 기지국을 위한 대기공간 광통신 장치의 제작과 특성평가)

  • Jin-Hyeon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.131-138
    • /
    • 2023
  • In this paper, a free space optical communication device that can be used in a mobile base station of several km or less was fabricated and its characteristics were investigated. To overcome the loss due to atmospheric transmission, an optical fiber amplifier (EDFA) with an output of 23 dBm or more was used. In order to increase the focusing speed and miniaturization of the laser beam, an optical lens was manufactured, and a transmission lens was designed to have beam divergence within the range of 1.5 to 1.8 [mrad]. A PT module that controls PAN/TILT was fabricated in order to reduce pointing errors and effective automatic alignment between transceiver devices. In this study, Reed-Solomon (RS) code was used to maintain the transmission quality above a certain level. It was manufactured to be able to communicate at a wireless distance of 300m in a weather situation with visibility of 300m. For performance measurement, it was measured using BERT and eye pattern analyzer, and it was confirmed that BER can be maintained at 2.5Gbps.