• 제목/요약/키워드: Operational performance

Search Result 2,034, Processing Time 0.03 seconds

A Systematic Review of the Dual-Task Training for Stroke With Hemiplegia (뇌졸중 환자에게 적용한 이중과제 훈련이 미치는 효과에 대한 체계적 고찰)

  • Lee, Yei-Jin;Jung, Min-Ye
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.1
    • /
    • pp.23-32
    • /
    • 2016
  • Objective : To investigate the current international researches which identify the effect of stroke with hemiplegia after dual-task training Methods : We systematically examined journals published from 2007 to 2015, searching PubMed. Total 5 researches were selected for the analyses. Results : Selected studies were all in international journal and they used two group experimental design. In addition, all the paper got PEDro scores above 6. They conducted gait task for motor task, at the same time used various domain of cognitive task such as from sustain attention to working memory. The outcome measure tools used for evaluation by the standardized assessment tool and operational definition, further also included the assessment tool designed for the dual-task training such as a variety of tools make possible to assess various aspects of effect. Discussion : Dual-task training in this study was found to give a positive effect on the dual-task performance, as well as improving the motor and cognitive function in patients with stroke. However there were also limitation to the studies conducted so far. In order to apply the occupational therapy, this results can consider as the preliminary data which suggest supplement point and can be a evidence for effective treatment for stroke with hemiplegia.

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF

A Study On Web Shopping Attitude and Purchasing Intention of Internet Self-Efficacy -Focus on Intrinsic and Extrinsic Motivation- (인터넷 자기효능감으로 인한 웹쇼핑에 대한 태도와 구매행동의도에 관한 연구 -내재적 동기와 외재적 동기를 중심으로-)

  • Lee, Jong-Ho;Sin, Jong-Kuk;Kim, Mi-Hye;Kong, Hye-Kyung
    • Journal of Global Scholars of Marketing Science
    • /
    • v.10
    • /
    • pp.1-26
    • /
    • 2002
  • The present study examines the role of subjectively perceived factors of the attitude toward web shopping in forming an intention to use a web shopping intention. An integrative research model is presented and tested empirically. It includes the following three aspects of belief in Davis' TAM: perceived usefulness, perceived ease of use, perceived enjoyment. Specially, internet self-efficacy, or the belief in one's capabilities to organize and execute courses of Internet actions required to produce given attainments, is a potentially important factor in efforts to gain more favorable attitude toward web shopping close the digital divide that separates experienced Internet users from novices. Prior research on Internet self-efficacy has been limited to examining specific task performance and narrow behavioral domains rather than overall attainments in relation to general Internet use, and has not yielded evidence of reliability and construct validity. Survey data were collected to develop a reliable operational measure of Internet self-efficacy and to examine its construct validity. Also, much previous research has established that perceived ease of use is an important factor influencing user acceptance and usage behavior of information technologies. However, very little research has been conducted to understand how that perception forms and changes over time. The present study examines that higher internet self-efficacy is more getting favorable web shopping attitude, and web shopping intention as more as usefulness, enjoyment through the internet.

  • PDF

Fabrication of Photocatalytic TiO2 thin Film Using Aerosol Deposition Method and its Filtration Characteristics (에어로졸 증착법을 이용한 광촉매 TiO2 박막 제조 및 박막의 여과 특성)

  • Choi, Wonyoul;Lee, Jinwoo;Kim, Shijun;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2010
  • The objective of this study is to evaluate the effect of operational parameters such as rotation speed and vibrating milling time for the fabrication of photocatalytic $TiO_2$ thin film using aerosol deposition methods. $TiO_2$ powders produced in the range of 1,000-3,000 rpm of rotation speed of centrifugal separator are ineffective on the fabrication of $TiO_2$ thin film by aerosol deposition due to the problem of nozzle powder jam. $TiO_2$ powders controlled by vibrating milling had about 420 nm of average diameter after 2 hr of vibrating milling time. The result of XRD analysis indicated that $TiO_2$ powders had a anatase phase. Vibrating milling methods was considered to be an effective pre-treatment process for $TiO_2$ powder control. Consequently $TiO_2$ photocatalytic thin film with dispersion of anatase crystallites controled by vibrating milling was successfully fabricated by aerosol deposition. The permeation flux of $TiO_2$ photocatalytic thin film with the immobilized $TiO_2$ powder was higher than that of suspended $TiO_2$ powder. Therefore, $TiO_2$ photocatalytic thin film promises to be one of the effective methods for enhancing filtration performance for the treatment of organic pollutants.

The Limitation of the Military Aviation Manufacturer's Liability (우리나라 군용항공기 제작사의 책임제한 해결방안에 관한 고찰)

  • Shin, Sung-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.1
    • /
    • pp.139-175
    • /
    • 2017
  • The Assembly plenary session on December 3, 2017 passed a Product Liability Amendment bill that introduced clauses concerning consumer burden of proof and punitive damage reimbursement. More specifically, these newly approved provisions will reduce the burden of proof placed on consumers and levy triple punitive damage on suppliers. Significant increases in the number of product-liability lawsuit and the number of related insurance contracts are expected. Since military aircraft are designed for operational purpose(seeking greater combat effectiveness over greater safety) and used in high-risk environment, it is practically impossible to obtain an affordable product-liability insurance, Without having any backup plan, military aircraft manufacturers directly face all sort of liability risks under Product Liability Act, Warrant Liability Act and Non-Performance of Contract Act. The U.S. experienced similar problems when they first implemented their product-liability law in 1970s. There had been a big dispute among legal practitioner, insurance professionals and scholars concerning military aircraft manufacturer's liability. In order to settle the issue, the U.S. Supreme Court has established a new precedent of Government Contractor Defense(GCD). The U.S. government also included an indemnity clause for military aircraft manufacturers in their FMS Contract with the Korean government. Likewise, Korean military aircraft manufacturers should 1) clearly understand their current position that they cannot afford expensive product-liability insurance and the cost is not accounted in the military procurement calculation, 2) estimate potential liability risks with the ongoing overseas export expansion in mind, 3) set up appropriate risk management measures through regulatory reform and policy development.

  • PDF

A study on performance comparison of jacket cooling fresh water system for marine diesel engine (선박용 디젤기관의 재킷 냉각청수시스템 성능 비교에 관한 연구)

  • Kim, Duk-Kyung;Lee, Jae-Hyun;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.8-14
    • /
    • 2017
  • Due to the financial crisis in 2008, the world economy collapsed leading to an increase in oil prices and a decrease in freight by shipping. To overcome this crisis, major shipping companies ordered larger ships, changed their trading route and improved operating of ships to overcome deficits. In particular, low-speed navigation was much favored by many companies so that it can reduce fuel consumption. However, the long-term operation of high-speed optimized engines in low-speeds has affected the jacket cooling fresh water (J.C.F.W.) system as they fail to maintain the normal operational temperature. The temperature of J.C.F.W. system dropped leading to low temperature corrosion. As a result, when the engine is operating at minimal load the functioning of existing J.C.F.W cooler is decreased and the use of fresh water generator is substantially limited. Therefore, an improvement in the functioning of J.C.F.W. system is necessary. In this paper, in order to review the improvements required for the operation of J.C.F.W. of low-speed operating marine diesel, an experiment was conducted by comparing and analyzing the results of the main engine J.C.F.W. system of a Panamax class bulk carrier 82k and a Cape class bulk carrier 180k by installing and uninstalling the J.C.F.W. Cooler. Thus, this paper proposed an improved design of the J.C.F.W. system that is suitable for the present low-speed operation.

Operational Characteristics of a Dry Electrostatic Precipitator for Removal of Particles from Oxy Fuel Combustion (순산소 연소 배출 입자 제거용 건식 전기집진장치 운전 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Oh, Won-Seok;Hwang, Gyu-Dong;Kim, Yong-Jin;Hong, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • In a test duct with closed configuration, particle removal performance of an edge-plate type electrostatic precipitator (ESP) was evaluated at a high flow rate in $CO_2$ rich environments by changing gap distances between collection plates, concentrations of $CO_2$, particle sizes, types of electrodes, and types of power supplies. At the same experimental conditions, collection efficiency of particles with the mean particle size, 300 nm, decreased as the gap distance and $CO_2$ concentration increased because of low electrostatic force and low discharged current. In addition, as the particle size increased, the efficiency increased because of high charging rate of the large particles. With the electrode type which has higher surface area of a discharging plate and with the power supply which applied 25 kHz-pulsed DC voltages, the removal efficiency was high even in rich $CO_2$ condition due to high electrostatic force at the same power consumption.

Analysis of Trial Test for ATP On-board Equipment of Tilting Train (틸팅열차 ATP 차상장치의 시운전시험 분석)

  • Baek, Jong-Hyen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3911-3916
    • /
    • 2010
  • In this paper we describe contents and results on running test for ATP on-board equipment, which has propelled as one of the research projects, so called, "Reliability assessment and operation technology development for Korean-type tilting trains" in order to ensure the safety and operation efficiency of tilting trains. We developed tilting trains for the speed-up of conventional lines and for the passenger service improvement where the KTX is not available. And we made progress the operation trial test in the 120,000 km distance with the use of ATS equipment, used in existing lines, for the purpose of the reliability assessment of the developed tilting trains. We decided to accelerate the speed for more than 200km/h with respect to the 6 existing lines including Jungang-line and Chungbuk-line where KTX has not operated. According to this decision, Train control system is to be changed from ATS to ATP. We should have installed an ATP on-board unit in tilting trains and verified the operational suitability, therefore we installed the same ATP on-board unit on tilting trains as that used in the ATP construction project on Gyeongbu-line and Honam-line, and verified that the function and performance of the installed ATP on-board unit conformed to the tilting trains operation.

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Investigation on the Allowable Transient Power Levels to Maintain the Mechanical Integrity of the 17$\times$17 KOFA Fuel Rod During the ANS Conditions I and II (ANS과도조건 I 및 II에서 17x17 KOFA 핵연료봉의 기계적 건전성이 유지되는 과도상태 허용 출력준위에 관한 연구)

  • Lee, Chan-Bock;Kim, Ki-Hang;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.119-125
    • /
    • 1994
  • Transient power level of the fuel rod is one of the key parameters for the transient fuel behavior. Through the analysis of the fuel performance data bases and sensitivity analyses of such parameters as rod power history, fast neutron flux, fuel enrichment and cycle length, which can affect the transient fuel behavior, a methodology generally applicable to find the allowable transient power level during the ANS Conditions I and II below which the mechanical integrity of the fuel rod is maintained was derived, and allowable transient power levels for the 17$\times$17 KOFA fuel rod have been determined as a function of the burnup. With the introduction of this methodology, design analysis of the transient fuel behavior currently being calculated every cycle can be replaced by the simple check of the peak transient power level achievable during the cycle, and an operational flexibility of the reactor can be obtained by allowing higher transient power level up to 689.5 w/cm at low burnup range than current maximum allowable transient power level, 591 w/cm for the 17$\times$17 KOFA fuel.

  • PDF