• 제목/요약/키워드: Operational Load

검색결과 428건 처리시간 0.021초

전력시장에서의 첨두용 수력운용방향과 수익구조 고찰 (Consideration of Operation and Income of Hydro-power for peak-load in the Electric-power pool)

  • 김승효;고영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.542-543
    • /
    • 2001
  • The purpose of this article is to search for desirable operational direction and compensation of hydro-power, after considering the electricity restructuring has influence on operation and profit of hydro-power for peak-load.

  • PDF

사용종료 쓰레기매립지의 장기침하특성 분석 (Long-term Settlement Characteristics of Closed Landfill)

  • 정하익;진현식;김상근;이강민;김태섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.605-610
    • /
    • 2002
  • Waste body settlement is an important aspect of management of landfill sites both during the operational and the post-closure phases. Settlement in landfill waste is caused by combination of load, creep and biodegradation induced effects. In this paper, settlement characteristics of closed waste landfill were studied by analyzing in situ measured data and computer simulation technique. Techniques for the analysis of load-induced and creep settlement, and for their implementation, can be adapted for landfill waste. The estimate of settlements from models shows a increase according to time.

  • PDF

DC Micro-Grid Operational Analysis with a Detailed Simulation Model for Distributed Generation

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon;Jeong, Yu-Seok;Yang, Hyo-Sik;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.350-359
    • /
    • 2011
  • This paper describes the operational analysis results of a DC micro-grid using a detailed model of distributed generation. A detailed model of wind power generation, photo-voltaic generation and fuel cell generation was implemented with an userdefined model created with PSCAD/EMTDC software and coded in C-language. The operational analysis was carried out using PSCAD/EMTDC software, in which the power circuit is implemented by a built-in model and the controller is modeled by an user-defined model that is also coded in C-language. Various simulation results confirm that a DC micro-grid can operate without any problems in both the grid-tied mode and in the islanded mode. The operational analysis results confirm that the DC micro-grid makes it feasible to provide power to the load stably. It can also be utilized to develop an actual system design.

운영 데이터를 활용한 제3자 물류 환경에서의 배송 트럭 무게 예측 (Truck Weight Estimation using Operational Statistics at 3rd Party Logistics Environment)

  • 이유진;최경민;김송은;박경수;정승환
    • 산업경영시스템학회지
    • /
    • 제45권4호
    • /
    • pp.127-133
    • /
    • 2022
  • Many manufacturers applying third party logistics (3PLs) have some challenges to increase their logistics efficiency. This study introduces an effort to estimate the weight of the delivery trucks provided by 3PL providers, which allows the manufacturer to package and load products in trailers in advance to reduce delivery time. The accuracy of the weigh estimation is more important due to the total weight regulation. This study uses not only the data from the company but also many general prediction variables such as weather, oil prices and population of destinations. In addition, operational statistics variables are developed to indicate the availabilities of the trucks in a specific weight category for each 3PL provider. The prediction model using XGBoost regressor and permutation feature importance method provides highly acceptable performance with MAPE of 2.785% and shows the effectiveness of the developed operational statistics variables.

습답 로터리 작업에 대한 농용 트랙터의 변속기 부하 가혹도에 관한 연구 (Severeness of Transmission Loads of Agricultural Tractor for Rotary Operations in Poorly Drained Paddy Field)

  • 한경훈;김경욱;오영근
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.293-300
    • /
    • 1999
  • The objectives of this study were to analyze the load acting on the transmission when tractor performed rotary operations in the poorly drained paddy fields and to compare its severeness with those obtained under different operational conditions. The loads were measured at the input shaft of the transmission and the load spectrum was constructed using the rain-flow cycle counting method. The severeness of the loads was represented by the partial damage sum which was determined by suing the modified Miner's rule. In the field with a shallow hardpan PTO speed affected severeness of the rotary operations greater than the forward speed did. In the field with deep hardpan, on the other hand, the effect of the forward speed was greater. the severeness in the well drained fields did not differ significantly from that in the field with a shallow hardpan. The severest load was recorded in the field with a deep hardpan.

  • PDF

Simulation and control of rotary snow plow

  • Kubota, Yuzuzu;Yamasita, Mitsuhisa;Hiromitsu-Hikita;Watabe, Tomoji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.869-874
    • /
    • 1988
  • The operational control of the rotary snowplow is considered to improve its working efficiency. The speed of the rotary snowplow is controlled, so that the load to the rotary snowplow is kept constant. As the load can not directly be detected, some items considered for the controlled variable are, for example, the engine revolution, the load pressure and etc. In order to examine these, the working simulation of the rotary snowplow was considered by introducing the experimental equation of the load. The control methods were examined by means of the simple digital control using the personal computer. These control methods were compared with simulations and experiments. Consequently, the working efficiency is improved about 20% than the manual operation.

  • PDF

Truck Scale 용 Load Cell의 Smart Interface Board 개발 (Development of Smart Interface Board for Truck Scale Load Cell)

  • 박찬원;박종연;홍재용;최규석;안광희
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.83-91
    • /
    • 1995
  • This paper presents the design of a smart A/D conversion interface used for measuring the load of a truck. Since the load-cell sensor to be used is very sensitive for weight variation, the interface board must have the low-drift and the A/D conversion for accuracy. A new integrator and comparator has been developed to reduce the offset voltage and the drift current of operational amplifiers and has been adapted into the interface board. Also, a software algorithm has been developed to obtain the stable and accrurate A/D conversion. This software includes a RS-485 communication program to control the interface, which gives a capability of backing-up the calibration data and transferring control data. The test and evaluation of the designed interface has been shown as having the better performance compared to the other types of existing weighing systems and sensor instruments.

  • PDF

굴착기의 부하율에 따른 실작업 질소산화물 배출 특성 연구 (Study on Real-Work NOx Emission Characteristics according to Load Factor of Excavator)

  • 신달호;박윤서;유철;박수한
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권3호
    • /
    • pp.1-8
    • /
    • 2023
  • The purpose of this study was to investigate and compare the impact of engine load on the emission characteristics of excavator engines, with the aim of improving the method for calculating the emission inventory of construction machinery. The engine load in excavators is directly correlated with the operational workload, and variations in the load factor (LF) can significantly influence the emission inventory. Thus, on-board diagnostic (OBD) data from an excavator at a construction site were systematically collected to measure engine output and emissions. The results revealed discernible differences in emissions based on engine load, even when the average excavator engine performance remained constant. This highlights the significant influence of the type and characteristics of the work being carried out on emission characteristics. Making realistic adjustments to the LF used in emission calculation formulas emerges as a crucial strategy for environmental improvement. Moreover, the analysis of the effects of engine load on emissions from excavators provides valuable insights for enhancing environmental protection measures.

선박기인 CO2 저감을 위한 에너지효율 운항지표에 관한 연구 (A Study on the Energy Efficiency Operational Indicator for CO2 Reduction from Ships)

  • 최재성;노범석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1035-1040
    • /
    • 2011
  • 본 논문에서는 IMO에서 논의 중인 운항선의 에너지효율지표에 대하여 연구를 수행하였다. IMO의 온실가스 저감을 위한 정책방안을 살펴보고 그 중 운항선에 대한 에너지효율지표를 분석하였다. 화물량에 대한 연료소비율 산정방법을 이용하는 에너지효율지표를 실제 운항선에 적용하여 결과를 분석하고 문제점을 제기하였다. 이를 바탕으로 엔진 부하에 대한 연료소비율을 이용하는 개선된 에너지효율지표를 제시하고 운항선에 적용하였다. 결과를 통해 개선된 에너지효율지표가 운항선에 대해 합리적인 이산화탄소 배출률을 정의할 수 있다고 판단하였다.

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.