• Title/Summary/Keyword: Operation range

Search Result 3,316, Processing Time 0.032 seconds

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Optimal Operation of a Switched Reluctance Motor using Choppingless Excitating (쵸핑없는 여자를 사용한 스윗치드 리럭탄스 전동기의 최적운전에 관한 연구)

  • Kwon, Young-Ahn
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.747-752
    • /
    • 1994
  • The switched reluctance motor has high efficiency over a wide range of speed and torque. However the switched reluctance motor exhibit comparatively low efficiency in the chopped excitation which produces additional inverter losses. This paper examines the optimal efficiency operation using choppingless excitation under the changed supply voltage. The excitation is designed to produce the required torque and speed satisfying the optimal efficiency in a nonlinear switched reluctance motor. The optimal algorithm is applied to 119 operation points which are chosen over the full range of driving torque and speed. The result in this paper indicate the improved efficiency comparing to the efficiency obtained by both switched and chopped excitataions under a fixed supply voltage.

Selective Dual Duty Cycle Controlled High Frequency Inverter Using a Resonant Capacitor in Parallel with an Auxiliary Reverse Blocking Switch

  • Saha, Bishwajit;Suh, Ki-Young;Kwon, Soon-Kurl;Mishima, Tomokazu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.118-123
    • /
    • 2007
  • This paper presents a new ZCS-PWM high frequency inverter. Zero current switching operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. Dual duty cycle control scheme is used to provide a wide range of high frequency AC output power regulation that is important in many high frequency inverter applications. It found that a complete soft switching operation can be achieved even for low power setting ranges by introducing high-frequency dual duty cycle control scheme. The proposed high frequency inverter is more suitable for consumer induction heating(IH) applications. The operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

Treatment for Hallux Valgus with Chevron Metatarsal Osteotomy in Patients over 60 Years Old (60세 이상의 고령에서의 중족골 절골술을 이용한 무지 외반증 치료)

  • Jeong, Bi O;Lee, Sang Hyeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.4
    • /
    • pp.223-228
    • /
    • 2012
  • Purpose: To treat hallux valgus in old age patients with chevron metatarsal osteotomy and to see the subsequent clinical and radiological outcomes. Materials and Methods: 23 cases of 18 hallux valgus patients of age 60 years or older who received proximal or distal corrective osteotomy from April 2007 to August 2009 and were followed up for at least 1 year were included in the study. The mean age at operation was 65 years (range, 60~81 years), and the mean follow-up period was 2 years and 6 months (range, 1 year~3 years 6 months). Clinical outcome was assessed with the American Orthopaedic Foot and Ankle Society (AOFAS) score, complications, satisfaction rate, as well as measurements and comparison of pre- and postoperative hallux valgus angles, the 1st~2nd intermetatarsal angle, and the position of hallucal medial sesamoid bone. Results: The AOFAS score was improved from preoperative average of 35.1 (range, 13-47) to average 85.1 at last follow-up (range, 75-100). Patients were satisfied about the operation in 21 cases (91.3%). Preoperative hallux valgus angle was $31.7^{\circ}$ on average (range, $19.1^{\circ}-48.9^{\circ}$), and $4.9^{\circ}$ on average at last follow-up (range, $0.3^{\circ}-21.2^{\circ}$). The 1st~2nd intermetatarsal angle was $14.4^{\circ}$on average (range, $8.7^{\circ}-25.7^{\circ}$) and $3.1^{\circ}$ on average at last follow-up (range, $0.6^{\circ}-7.5^{\circ}$). The hallucal medial sesamoid bone position was improved from preoperative average 3.5 (range, 3-4) to postoperative average 1.0 (range, 0-2). Conclusion: Proximal and distal metatarsal osteotomy treatment yielded good clinical and radiological outcomes in old age hallux valgus patients.

Smooth Torque Speed Characteristic of Switched Reluctance Motors

  • Zeng, Hui;Chen, Zhe;Chen, Hao
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.341-350
    • /
    • 2014
  • The torque ripple of switched reluctance motors (SRMs) is the main disadvantage that limits the industrial application of these motors. Although several methods for smooth-toque operation (STO) have been proposed, STO works well only within a certain torque and speed range because of the constraints of the supply voltage and peak current. Based on previous work that sought to expand the STO range, a scheme is developed in this study to determine the maximum smooth torque range at each speed. The relationship between the maximum smooth torque and speed is defined as the smooth torque speed characteristics (STSC), a concept similar to torque speed characteristics (TSC). STSC can be utilized to evaluate torque utilization by comparing it with TSC. Thus, the concept benefits the special design of SRMs, especially for the generation of smooth torque. Furthermore, the torque sharing function (TSF) derived from the proposed method can be applied to STO, which produces a higher smooth torque over a wider speed range in contrast to four typical TSFs. TSimulation and experimental results verify the proposed method.

High Efficiency Design Procedure of a Second Stage Phase Shifted Full Bridge Converter for Battery Charge Applications Based on Wide Output Voltage and Load Ranges

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.975-984
    • /
    • 2018
  • This work presents a high efficiency phase shifted full bridge (PSFB) DC-DC converter for use in the second stage of a battery charger for neighborhood electrical vehicle (EV) applications. In the design of the converter, Lithium-ion battery cells are preferred due to their high voltage and current rates, which provide a high power density. This requires wide range output voltage regulation for PSFB converter operation. In addition, the battery charger works with a light load when the battery charge voltage reaches its maximum value. The soft switching of the PSFB converter depends on the dead time optimization and load condition. As a result, the converter has to work with soft switching at a wide range output voltage and under light conditions to reach high efficiency. The operation principles of the PSFB converter for the continuous current mode (CCM) and the discontinuous current mode (DCM) are defined. The performance of the PSFB converter is analyzed in detail based on wide range output voltage and load conditions in terms of high efficiency. In order to validate performance analysis, a prototype is built with 42-54 V / 15 A output values at a 200 kHz switching frequency. The measured maximum efficiency values are obtained as 94.4% and 76.6% at full and at 2% load conditions, respectively.

Range Safety System Operation in KSR-III Flight Test (KSR-III 비행안전 시스템 운영)

  • Ko, Jeong-Hwan;Kim, Jeong-Rae;Park, Jeong-Joo;Bang, Hee-Jin;Choi, Dong-Min;Song, Sang-Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.91-97
    • /
    • 2004
  • The first Korean liquid propellant rocket KSR-III successfully finished its flight test on Nov. 28, 2002. Herein, we summarize the results of range safety system operation which is employed for the first time in flight tests of rockets developed by Korea Aerospace Research Institute(KARI). During the flight, safety-critical flight data including instantaneous impact points are monitored in realtime by range safety officers utilizing Range Safety Display Systems. The recorded screen of the display system is presented for the explanation of safety operation. In addition, comparisons are made between onboard navigation system based and radar based results in calculating instantaneous impact points, and also errors from the finally recorded impact point are described.

Asymmetrical Half-bridge Flyback Converter with Universal Input Voltage Range (넓은 입력전압 범위에서 동작하는 비대칭 하프브리지 방식의 플라이백 컨버터)

  • Yoo, Doo-Hee;Lee, Jae-Min;Jeong, Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.124-126
    • /
    • 2007
  • This paper presents an asymmetrical half-bridge flyback converter with universal input voltage range. The leakage inductance and output capacitance of active switches are used to realize zero voltage switching(ZVS) operation during the transition state between two switches. In this paper, the operating principle and system analysis of the adopted converter are discussed in detail. A 5V/20A prototype has been implemented to verify the proposed topology and theoretical operation under various load condition and universal input voltage range.

  • PDF

Laparoscopic Surgery for Intussusception in Children (소아 장중첩증에 대한 복강경 수술의 경험)

  • Yoon, Doo Hwan;Nam, So-Hyun
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.66-72
    • /
    • 2013
  • Intussusception is common cause of intestinal obstruction in children. Most of intussusceptions can be treated with non-operative reduction using air or barium. However, about 10% patients need operative treatment due to failure of reduction, peritonitis, and recurrence after reduction. We introduce our experience of laparoscopic surgery for intussusception. From April 2010 to March 2013, we reviewed 57 children who diagnosed intussusception. Twelve patients underwent an operation. The cause of operation was 7 of failure of air reduction and 5 of recurrence after air reduction. Median age was 21.5 months (range: 5.0~57.7 months) and 11 children (91.7%) underwent successful laparoscopic reduction. Median operating time was 50 minutes (range: 30~20 minutes) and median hospital days was 4.5 days (range: 3~8 days). One patient had a leading point as a heterotopic pancreas and underwent bowel resection through conversion. There was neither intra-operative nor postoperative complication. Laparoscopic reduction for intussusception can bring an excellent cosmetic effect with high success rate.