• Title/Summary/Keyword: Operation range

Search Result 3,309, Processing Time 0.031 seconds

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

A V-I Converter Design for Wide Range PLL (넓은 주파수 영역 동작의 PLL을 위한 V-I 변환기 설계)

  • Hong, Dong-Hee;Lee, Hyun-Seok;Park, Jong-Wook;Sung, Man-Young;Lim, Shin-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.52-58
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). The recent TCON requires wide range frequency operation of $8\sim135MHz$ in PLL. In order to be satisfied this requirement the new V-I converter.circuit. The V-I converter of new architecture increased the minimum/maximum current ratio which widens the operation frequency range of VCO's md also guaranteed linearity of VCO's. The proposed PLL circuits in FPD TCON show the measuring performance of loops RMS jitter in the range of $8\sim135MHz$. The designed circuit was fabricated in 1-ploy 3-metal 0.25um TSMC process technology and has a operation range or $8\sim135MHz$ with 2.5V power.

A Design and Fabrication of Test Equipment for Airborne Tracking Radar Test (항공기용 추적레이더 시험을 위한 시험장비의 설계 및 제작)

  • Yoon, Seung-Gu;Park, Seung-wook;Kwon, Jun-Bum;Jung, Man-Seek
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.352-361
    • /
    • 2017
  • This paper proposes a design and fabrication of the test equipment that is implemented as a part of the airborne tracking radar inspection under the environment of indoor simulation. This test equipment provides controlling the operation status of airborne tracking radar and replicating the velocity and range information of target by generating a variety of target signal. This is mainly composed of radar operation controller, target signal generator, horn antenna driving devices. Radar operation controller is able to perform the controlling of radar operation mode and monitoring in real time by serial communication. Target signal generator is generated doppler signal and range delayed signal using virtual target of RF-band. Horn antenna driving devices perform a role of target simulating exercise. In the end, the performance is demonstrated using experiment results of test equipment for airborne tracking radar.

A study on the improvement of the thermal expansion formula of the insulating oil in electric facilities (전력설비 절연유 열팽창 계산식 개선에 관한 연구)

  • Rim, Seong-Hwang;Moon, Bong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • The transformer and the OF cable are cooled and insulated by insulating oils in their body. The insulating oil expands or contracts with the heat transfer according to the operating conditions of the electric facilities. So we install the $N_2$ gas tank connected with the insulating oil system to overcome the change. The change of the insulating oil volume for the operation temperature range must be calculated to decide the $N_2$ gas volume and to set the alarm point for safe operation. It is known that this change is proportional to the temperature change and to the insulating oil volume if the temperature change is small enough.[1][11] However this proportional formula has been accepted generally in the design of electric facilities for wide operation temperature range such as $40^{\circ}C{\sim}125^{\circ}C$. Hence, it makes large errors in calculation which car result in serious damage against safe operation of the electric facilities. This paper presents a improved method of calculating the accurate change of the insulating oil volume to insure the safe operation of electric facilities.

  • PDF

Fine Seek Control of Extended Applicable Range for Optical Disk Drives

  • Ryoo, Jung-Rae;Jin, Kyoung-Bog;Doh, Tae-Young;Chung, Myung-Jin
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.146-151
    • /
    • 2001
  • Optical disk drive has excellent advantage of random accessibility of which performance is measured by access time. However, due to the increased rotational velocity of the disk and constraints of mechanical structure, two-stage seek algorithm which executes coarse and fine seeks sequentially has been adopted in most commercial optical disk drives. Although the laser spot is moved to a target track by a single seek operation, the limited operation range of the fine actuator restricts the application of the fine seek algorithm below a few hundreds of tracks. Especially, excessive movement of the objective lens causes a failure in generation of track-cross pulse and results in an unstable seek operation. In this paper, a new control algorithm for extending the fine seek range is proposed with an appropriate control structure. The coarse actuator is utilized to reduce the misalignment between the objective lens and the laser beam axis, and the fine actuator is controlled to follow the reference velocity trajectory. The proposed algorithm is applied to a CD-ROM drive to show its feasibility and some experimental results are presented.

  • PDF

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

High Efficiency Design Considerations for the Self-Driven Synchronous Rectified Phase-Shifted Full-Bridge Converters of Server Power Systems

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.634-643
    • /
    • 2015
  • This paper presents a high frequency design approach for improving efficiency over a wide load range in the self-driven phase-shifted full-bridge converters for server power systems. In the proposed approach, a detailed ZVS analysis of the lagging leg switches in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM) is presented. The optimum dead time and the determination of the appropriate operation mode are given for high efficiency according to the load conditions. Finally, the optimum operation conditions are defined to achieve a high-efficiency. A laboratory prototype operating at 80 kHz, rated 1 kW (12 V-83.3 A), is built to verify proposed theoretical analysis and evaluations. The experimental results show that the maximum efficiency is achieved as 95% and 83.5% at full load and 5% load conditions, respectively.

Vibration of Massive Tunnel Structure Induced by Subway Operation (지하철 운행에 의한 중량터널의 진동)

  • 김희철;신효근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.114-121
    • /
    • 1995
  • Problems of noise and vibration induced by subway operation became one of the major factor when new subway 1 me is under consideration. One of the most economic method in reducing the noise and vibration is the increasement of the tunnel mass. . Vibration of the massive tunnel structure has been measured induced by subway operation. STEDEF system which was adopted by Seoul Metropolitan Subway Bureau has been proved that more than 99% of the vibration has been decreased at the bottom of the railway track. Most of the vibration measured inside and outside of the tunnel showed that their peak frequency is around SOHz or 100Hz. The propagation characteristics of vibration in massive tunnel , wave propagate in three directions. Overall frequency in the range of 0 to 125H2 horizontal transmission usually increase, while vertical transmission decreases about 50% in the range of 0 to 25Hz and 90Hz to 125Hz regardless of modal shape.

  • PDF

Control of Booster Output Voltage in Fuel Cell Power Plant (연료전지발전용 부스터의 출력전압제어 연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF

Development of a Wideband EPR Spectrometer with Microstrip and Loop Antennas

  • Ponomaryov, A.N.;Choi, K.Y.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.178-182
    • /
    • 2013
  • We have developed a new non-conventional electron paramagnetic resonance (EPR) spectrometer, in which no resonant cavity was used. We previously demonstrated a wide frequency range operation of an EPR spectrometer using two loop antennas, one for a microwave transmission and the other for signal detection [1]. In contrast to Ref. [1], the utilization of a microstrip antenna as a transmitter enhanced a capability of wide-band operation. The replacement of conventional capacitors with varactor diodes makes resonance condition easily reproducible without any mechanical action during tuning and matching procedure since the capacitance of the diodes is controlled electronically. The operation of the new EPR spectrometer was tested by measuring a signal of 1,1-diphenil-2-picrylhydrazyl (DPPH) sample in the frequency range of 0.8-2.5 GHz.