• Title/Summary/Keyword: Operation limit

Search Result 876, Processing Time 0.033 seconds

MECHANISATION SYSTEM FOR LARGE SCALE GRAIN MAIZE PRODUCTION IN MALASIA

  • Abu-Hassan, D.;Nor, J.M.;Daham, M.D.M.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.158-173
    • /
    • 1993
  • The formulated mechanization packages for grain maize production have performed to the expected limit generating encouraging information. Besides physical feasibility , management factors viz ; production operation sequence, operations scheduling and machinery matching with respect to environment can still limit system suitability. A new production operation sequence was introduced to overcome weed problems and limitations of available working days. Proper operations scheduling will improve the initial soil-crop environment for better seedling establishment, and reduce the (). been identified as key factors to reduce capital investment and cost of proudction .

  • PDF

Current Limit Control for a Four-quadrant Operation of SRM Drive (SRM의 4상한 구동을 위한 전류제한 방식)

  • 안진우;강유정
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.285-291
    • /
    • 2003
  • Switched reluctance machine has much attention as a traction drive because of high efficiency, high power and DC series torque characteristics. But the motor has to have a regenerative mode when it is adopted in electric vehicle and current divergence during the regeneration makes difficulties in the control. This paper proposes a reference current limitation strategy for a stable regeneration based on simulations and experimented tests. The motor is operated with conventional current limit and switching angle control method in motoring mode. Simulations and experiments are excuted to verify the feasibility of the proposed method.

Instantaneous Torque Control of IPMSM for Drive of Wide Speed Range (광범위한 속도영역의 운전을 위한 IPMSM의 순시 토크제어)

  • Lee, Jung-Chul;Lee, Hong-Gyun;Jung, Tack-Gi;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.183-186
    • /
    • 2002
  • The paper is proposed intantaneous torque control of IPMSM for drive of wide speed range. The control scheme is based on the mathematical model of the motor and is applicable to the constant torque and field weakening operations The scheme allows the motor to be driven with maximum torque per ampere (MTPA) characteristic below base speed and it maintains the maximum voltage limit of the motor wide field weakening and the motor current limit under all conditions of operation accurately. For each control mode. a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. The proposed control algorithm is applied to PMSM drive system for drive of wide speed range, the operating characteristics controlled by maximum torque control are examined in detail by simulation.

  • PDF

Experimental Study on the Performance Improvement of Aluminum Grooved Heat Pipe due to increased number of Grooves (그루브수 증가에 따른 알루미늄 그루브 히트파이프의 성능향상에 관한 실험적 연구)

  • 홍진관;최상곤;김대성;정원복;변윤식;영권옥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.474-481
    • /
    • 2001
  • Aluminum/Freon22 grooved hat pipes which have 26 axial grooves in a cross-section were manufactured and tested. The performance test was conducted by varying filling ratio and tilt angle. Operation limit, thermal resistance, overall heat transfer coefficient were investigated. The experimental result was compared with previous study which conducted in the case of a heat pipe with combined wick. The experimental result shows that thermal resistance of this heat pipe is twice smaller than that of the heat pipe with combined wick and operation limit is increased about 75%, comparing with that of heat pipe with combined wick.

  • PDF

Experimental Study on the Working Characteristic of Aluminum Grooved Heat Pipe and Thermosyphon with Inner Arterial Wick (내부 아터리가 있는 알루미늄 그루브 히트파이프와 써모사이펀의 작동특성에 관한 실험적 연구)

  • 홍진관;김대성;정원복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.894-900
    • /
    • 2000
  • The experimental study for performance improvement of aluminum/freon22 grooved heat pipe was carried out. Arterial wick was used for performance improvement of heat pipe. The experimental result was compared with screen covered grooved wick heat pipe. And also, performance test of grooved wick thermosyphon inserted straight wire in the center of grooved pipe was carried out. This result was compared with the performance test result of grooved wick thermosyphon. The operation limit of artery inserted grooved heat pipe was slightly extended, but thermal resistance of this heat pipe was twice as large as that of screen covered grooved heat pipe. In case of thermosyphon, the operation limit of grooved thermosyphon inserted straight wire in the center of grooved pipe was slightly extended, but thermal resistance was increased, comparing with that of the grooved thermosyphon.

  • PDF

An Improved Voltage Control Scheme for DC-Link Voltage Balancing in a Four-Level Inverter (4-레벨 인버터의 DC-링크 전압 균형을 위한 향상된 전압 제어 기법)

  • Kim, Rae-Yeong;Lee, Yo-Han;Choe, Chang-Ho;Hyeon, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.544-554
    • /
    • 1999
  • Multi-level inverters are now receiving widespread interest form the industrial drives for high power variable speed applications. Especially, for the high power variable speed applications, a diode clamped multi-level inverter has been widely used. However, it has the inherent problem that the voltage of the link capacitors fluctuates. This paper describes a voltage control scheme effectively to suppress the DC-link potential fluctuation for a diode clamped four-level inverter. The current to flow from/into the each link capacitor is analyzed and the operation limit is obtained when a conventional SVPWM is used. To overcome the operation limit, a modified carrier-based SVPWM is proposed. Various simulation and experiment results are presented to verify the proposed voltage control scheme for DC-link voltage balancing.

  • PDF

Operation Limit of Flow Control for a Bistable Fluidic Valve

  • Lee, Ji Ung;Hong, Ji-Seok;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.389-394
    • /
    • 2017
  • The limitation of flow control for a bistable fluidic valve has been investigated. The physical model of the fluidic valve includes two main flow outlets and two control flow inlets. The experiments were conducted with pressure regulators, mass flow meters, and piezo sensors to analyze flow switching characteristics of the fluidic valve. The experimental data such as pressure and mass flow rate of control flows and the switching time of the main flow was obtained with various operating conditions. The operation limit of the fluidic valve is identified, and a model equation for pre-estimating the minimum control pressure to switch the direction of the main flow has been proposed.

Delayed Scheduling under Resource Constrains (자원제약하에서의 지연 스케쥴링)

  • Shin, In-Soo;Lee, Keun-Man
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.10
    • /
    • pp.2571-2580
    • /
    • 1997
  • In this paper, we deal with the resource constrain scheduling to execute behavior algorithm under resource limit. Expecially, we proposed a scheduling algorithm, called delayed scheduling, which finds the lower bound control step to assign operation under resource limit. We take in account the actual scheduling problems including multicycle operation and functional pipelining. Integer Linear Programing formulations are used to the scheduling problems in order to get optimal scheduling result. Experiment was done on the DFG model of fifth-order digital wave filter, to show it's effectiveness.

  • PDF

Determination of Radionuclide Concentration Limit for Low and Intermediate-Level Radioactive Waste Disposal Facility II: Application of Optimization Methodology for Underground Silo Type Disposal Facility (중저준위방사성폐기물 처분시설의 처분농도제한치 설정에 대한 고찰 II: 최적화 방법론 개발 및 적용)

  • Hong, Sung-Wook;Kim, Min Seong;Jung, Kang Il;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.265-279
    • /
    • 2017
  • The Gyeongju underground silo type disposal facility, approved for use in December 2014, is in operation for the disposal of low and very low-level radioactive wastes, excluding intermediate-level waste. That is why the existing low-level radioactive waste level has been subdivided and the concentration limit value for intermediate-level waste has been changed in accordance with Nuclear Safety Commission Notice 2014-003. For the safe disposal of intermediate-level wastes, new optimization methodology for calculating the concentration limit of intermediate radioactive level wastes at an underground silo type disposal facility was developed. According to the developed optimization methodology, concentration limits of intermediate-level wastes were derived and the inventory of radioactive nuclides was evaluated. The operation and post closure scenarios were evaluated for the derived radioactive nuclide inventory and the results of all scenarios were confirmed to meet the regulatory limit. However, in case of $^{14}C$, it was confirmed that additional radioactivity limitation through a well scenario was needed in addition to the limit of disposal concentration. It was confirmed that the derived intermediate concentration limit of radioactive waste can be used as the intermediate-level waste concentration limit for the underground disposal facility. For the safe disposal of intermediate-level wastes, KORAD plans to acquire additional data from the radioactive waste generator and manage the cumulative radioactivity of $^{14}C$.

Analysis of effect on power system considering the maximum penetration limit of wind power (풍력발전 한계운전용량에 대한 계통영향 분석)

  • Myung, Ho-San;Kim, Bong-Eon;Kim, Hyeong-Taek;Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.19-25
    • /
    • 2012
  • About supply and demand to see that you need to match, the limitations of wind power capacity is low demand and the commitment of the general generator will exist between the minimum generation. if the turbine's output can be controlled, The limitation of wind power capacity will be adopted based on instant power generation. Namely, The minimum limits of wind power generation based load operation by calculating the amount that is higher than if the output should be restricted to highest operation. in this paper, we committed to the demand for low enough that the combination of the general generator of wind power capacity to accommodate the operation of determining whether the limit is intended to. For this, power system analysis program PSS/E was used, Jeju system by implementing the model simulations were performed.