• Title/Summary/Keyword: Operation Verification

Search Result 896, Processing Time 0.028 seconds

Manual Development Research for the Diagnosis of the Introduction of Low-Floor Bus (저상버스 도입진단 매뉴얼 개발 연구)

  • Seung jun Lee;Seong yeon Kim;Won Jun Lee;Hyunjun Park;Choul Ki Lee;Nam sun Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.6
    • /
    • pp.208-222
    • /
    • 2023
  • With the recent revision of 「Act on Promotion of the Transportation Convenience of Mobility Disadvantaged Persons」 and the Enforcement Regulations of the Act, bus business operators must introduce low-floor buses when scrapping buses. On the other hand, in the case of routes where low-floor buses cannot be operated, bus business operators can be exempted from introducing low-floor buses with the approval of their transportation administrative agency according to Article 4-2 of 「Enforcement Regulation of the Act on Promotion of the Transportation Convenience of Mobility Disadvantaged Persons」. According to the data from the Korea Bus Transportation Associations Federation, approximately 5.9% of all city bus routes were surveyed as the exceptions to introducing low-floor buses. Nevertheless the proportion is expected to increase because some regions with difficulties introducing low-floor buses are not included when calculating the proportion. By confirming the process of approving exceptions for introducing low-floor buses through local governments, there was no specific examination method or standard for approval of exceptions. Hence, there is the problem that some routes are approved as exceptions to introducing low-floor buses, even though low-floor buses can be operated on those routes. Therefore, this study aims to develop a manual that can objectively diagnose the overall operation environment of low-floor buses, such as road geometry and road facilities. Future research plans to apply it to more cases and improve it for more precise application in various contexts.

Verification of Kompsat-5 Sigma Naught Equation (다목적실용위성 5호 후방산란계수 방정식 검증)

  • Yang, Dochul;Jeong, Horyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1457-1468
    • /
    • 2018
  • The sigma naught (${\sigma}^0$) equation is essential to calculate geo-physical properties from Synthetic Aperture Radar (SAR) images for the applications such as ground target identification,surface classification, sea wind speed calculation, and soil moisture estimation. In this paper, we are suggesting new Kompsat-5 (K5) Radar Cross Section (RCS) and ${\sigma}^0$ equations reflecting the final SAR processor update and absolute radiometric calibration in order to increase the application of K5 SAR images. Firstly, we analyzed the accuracy of the K5 RCS equation by using trihedral corner reflectors installed in the Kompsat calibration site in Mongolia. The average difference between the calculated values using RCS equation and the measured values with K5 SAR processor was about $0.2dBm^2$ for Spotlight and Stripmap imaging modes. In addition, the verification of the K5 ${\sigma}^0$ equation was carried out using the TerraSAR-X (TSX) and Sentinel-1A (S-1A) SAR images over Amazon rainforest, where the backscattering characteristics are not significantly affected by the seasonal change. The calculated ${\sigma}^0$ difference between K5 and TSX/S-1A was less than 0.6 dB. Considering the K5 absolute radiometric accuracy requirement, which is 2.0 dB ($1{\sigma}$), the average difference of $0.2dBm^2$ for RCS equation and the maximum difference of 0.6 dB for ${\sigma}^0$ equation show that the accuracies of the suggested equations are relatively high. In the future, the validity of the suggested RCS and ${\sigma}^0$ equations is expected to be verified through the application such as sea wind speed calculation, where quantitative analysis is possible.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

A Study on their Health Promotion Behavior Influenced by Primary School Students' Self-concept (초등학생의 자아개념이 건강증진행위에 미치는 영향)

  • Lee, Deog-Weon;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.29-48
    • /
    • 2000
  • This study was designed to diagnose the correlations between health promotion behavior and primary school students' demographic characteristics and their self-concept, and also this study was aimed at representing the basic data of proper instruction method and school health program with the respective to primary school students' health promotion behavior through the above things. For this, author selected as 5th, 6th graders, 400 persons at 5 elementary schools located on Kyonggi province. This data utilized ANOVA, multiple regression analysis and correlation analysis by SPSS program. The findings of this study were as follows; First, there showed meaningful differences concerning their health promotion behavior according to students' demographic traits. There were a birth date, living standard, domestic environments etc. as a factors which influenced on their health promotion behavior. With this, from ex-past-facto verification for these variable factors, as their birth date was faster, living standard was higher, domestic environments was better, as their health promotion behavior was more promotive. Second, students' health promotion behavior marked 3.61 among total 5 paint with the respective to its fulfillment degree, their self-concept marked 3.45 among total 5 paint. Their mental health promotion behavior marked 3.71 with the respective to inferior category of health promotion behavior, which was the highest score. In the other hands, their physical health promotion behavior marked 3.71, social health promotion behavior marked 3.45. contrary the disease prevention, first-aid & safety, oral health, health & nutrition(P>.05). Third, there show meaningful difference, in the level of p-value <.001 with the respective to the correlations between primary school students' health promotion behavior and their self-concept, more their self-concept was positive, more their more their whole health promotion behavior(r=.479), the fulfillment degree of physical health promotion behavior(r=.384), mental health promotion behavior(r=.543), social health promotion behavior(r=.372) were high. Fourth, with the respective to the results of difference verification concerning their fulfillment degree of health promotion behavior according to the upper, middle, inferior group of self-concept, there showed statistically meaningful difference, in the level of p-value<.001. In the long run, more their self-concept was positive, more their whole health promotion behavior was high. With this, from the results of $Scheff\acute{e}$ verification, there showed meaning differences among the upper and middle group, upper and inferior group, middle and inferior group. Fifth, self-concept played the role as the most important prognostic factor with the respective to primary school students' health promotion behavior(23.0%), in the other hands, there showed positive weight of 24.0% concerning the fulfillment of whole health promotion behavior by domestic environments(1.0%). From the above results, primary school students' the fulfillment degree of health promotion behavior didn't reach to middle or inferior level. In the other hands, there showed positive effects in the correlations between self-concept and the fulfillment degree of health promotion behavior, and also high self-concept group was much positive considering inferior group in the fulfillment degree of health promotion behavior. Accordingly, more their self-concept was positive, more their fulfillment degree of health promotion behavior was effective. Eventually, in the future, there have to make an efforts to develope positive, substantial programs through their self-concept enhancement etc. in the adequate planning or operation for primary school students' health education and school health program.

  • PDF

The Impact of Justice of Layoff on Management Trust, Job Satisfaction and Organizational Commitment in the Hotel Corporations (호텔기업에 있어 구조조정상의 공정성 지각이 경영진의 신뢰, 직무만족 및 조직몰입에 미치는 영향)

  • Kim, Young-Soon;Ahn, Dae-Hee
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.1
    • /
    • pp.115-139
    • /
    • 2008
  • Since financial crisis of IMF resulted in intensive competitiveness and adverse management environment, many hotel industries have responded it with restructuring. Since this restructuring is accompanied by reduction of employees, hence comes the recognition of justice in the procedure of restructuring. When the surviving employees in the restructuring process recognize unfairness in the procedure and practical operations, organization effectiveness can not be maintained due to losing trust of their employers. In this paper I will examine the relationship between validity of restructuring and compensatory programs for layoffs and surviving employees' trust of the employers. Also I will find out the relationship between remaining employees' trust of the employers and their job satisfaction and organization commitment. Through this relationship, we can prepare an alternative to reduce negative effect of restructuring. The hypotheses of this study are proposed as follows: H1: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their trust with a manager of the company is. H2: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their trust with a manager of the company is. H3: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their job satisfaction is. H4: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their job satisfaction is. H5: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their organization commitment is. H6: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their organization commitment is. H7: The higher surviving employees' trust with a manager of the company in restructuring process is, the higher their job satisfaction is. H8: The higher surviving employees' trust with a manager of the company in restructuring process is, the higher their organization commitment is. For the purposes of this study, employees working in luxury hotels located in Seoul were targeted. Self-administered questionnaires were distributed to those who consented with the investigation after explaining the purpose of the survey. A total of 500 questionnaires were distributed and 450 questionnaire were returned to the researcher for analysis. 430 of the returned questionnaires were used for analysis. As for the education for this survey, 250 junior college graduates or under (58.1%), 143 college graduates (33.3%) and 37 graduate school graduates (8.6%). As for the marital status, 315 persons (73.3%) are single and 115 are married (26.7%). As for the monthly income, 49 people (11.48%) are less than 2 million won, 148 (34.4%) are between 2 million and less than 2.5 million won, 153 (35.6%) are between 2.5 million to less than 3 million won, 80 (18.6%) are more than 3 million won. As for the workplace, 293 people (68.1%) work for the F&B department, 73 (17.0%) for rooms department, 41 (9.5%) for operation/ marketing department, 23 (5.3%) for account/ general affair department. As for the period of employment, 85 people (19.8%) are less than 5 years, 150 (34.9%) are between 6 to 9 years, 143 (33.3%) are between 10 to 14 years. and 52 (3.%) are more than 15 years. An exploratory factor analysis was used to survey validity and reliability of calculating tool on perceived values. This study used correlation between individual items and whole items and Cronbach's alpha value of multiple-item scale which is usually used to assess scale and reliability. Reliability of conceptual sub-dimension was assessed by basing on repeated procedure of correlation between individual items and whole items and factor loading. 1. Verification of correlation between validity of restructuring and trust This research showed that procedural and distributive justice of restructuring affects trust positively. The path coefficient between procedural justice of restructuring and trust is 0.719(t=10.135, p=0.000), and thereby the higher procedural justice results in higher trust. The path coefficient between distributive justice of restructuring and trust is 0.160(t=3.291, p=0.001), and thereby the higher distributive justice results in higher trust. Hence H1 and H2 are accepted. 2. Verification of correlation between validity of restructuring and job satisfaction The path coefficient between procedural justice of restructuring and job satisfaction is 0.179(t=2.202, p=0.028), and thereby the higher procedural justice results in higher job satisfaction. The path coefficient between distributive justice of restructuring and job satisfaction is 0.074(t=1.620, p=0.105), and thereby distributive justice of restructuring has no relationship with job satisfaction. Hence H3 is accepted, but H4 is removed. 3. Verification of correlation between validity of restructuring and organization commitment The path coefficient between procedural justice of restructuring and organization commitment is 0.188(t=2.466, p=0.014), and thereby the higher procedural justice results in higher organization commitment. The path coefficient between distributive justice of restructuring and organization commitment is 0.118(t=2.720, p=0.007), and thereby the higher distributive justice results in higher organization commitment. Hence H5 and H6 are accepted. 4. Verification of correlation between trust and job satisfaction The path coefficient between trust and job satisfaction is 0.610(t=6.736, p=0.000), and thereby the correlation has a meaningful result. Since the higher trust of the employer results in higher job satisfaction, H7 is accepted. 5. Verification of correlation between trust and organization commitment The path coefficient between procedural justice of restructuring and job satisfaction is 0.446(t=5.547 p=0.000), and thereby the higher trust of the employer results in higher organization commitment. Hence H8 is accepted. This research aimed to help the employers of hotel industries by analyzing the effects of validity of restructuring on employees' trust, job satisfaction and organization commitment. The research found that employer's validity of restructuring has significant affects on the degree of employee's trust with a manager, thereby reducing the negative effects of restructuring and enhancing organization commitment and job satisfaction. The principal purpose of this research is to confirm the correlation between employees' perceived validity of restructuring and their trust with a manager. Also whether this correlation results in competitive edge of the company is also investigated. It is also pointed out that employees had to participated the procedure of restructuring, sharing the philosophy and reason of restructuring. This participation and furthermore compensatory methods can reduce employees' anxiety of organization operations. Variable of trust appeared to have impact on intermediation effect between perceived variable of validity and job satisfaction, organization commitment, so that increase of trust with a manager plays an crucial role in increasing organization effectiveness. Since this research did not cover whole hotel industries which underwent restructuring, it showed a limit. Unlike previous studies which dealt with validity and trust of superior bosses, this research focussed on employers. Also the organization citizenship which is not considered in this study will be dealt with in the future study.

  • PDF

Experimental Analysis of Nodal Head-outflow Relationship Using a Model Water Supply Network for Pressure Driven Analysis of Water Distribution System (상수관망 압력기반 수리해석을 위한 모의 실험시설 기반 절점의 압력-유량 관계 분석)

  • Chang, Dongeil;Kang, Kihoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.421-428
    • /
    • 2014
  • For the analysis of water supply network, demand-driven and pressure-driven analysis methods have been proposed. Of the two methods, demand-driven analysis (DDA) can only be used in a normal operation condition to evaluate hydraulic status of a pipe network. Under abnormal conditions, i.e., unexpected pipe destruction, or abnormal low pressure conditions, pressure-driven analysis (PDA) method should be used to estimate the suppliable flowrate at each node in a network. In order to carry out the pressure-driven analysis, head-outflow relationship (HOR), which estimates flowrate at a certain pressure at each node, should be first determined. Most previous studies empirically suggested that each node possesses its own characteristic head-outflow relationship, which, therefore, requires verification by using actual field data for proper application in PDA modeling. In this study, a model pipe network was constructed, and various operation scenarios of normal and abnormal conditions, which cannot be realized in real pipe networks, were established. Using the model network, data on pressure and flowrate at each node were obtained at each operation condition. Using the data obtained, previously proposed HOR equations were evaluated. In addition, head-outflow relationship at each node was analyzed especially under multiple pipe destruction events. By analyzing the experimental data obtained from the model network, it was found that flowrate reduction corresponding to a certain pressure drop (by pipe destruction at one or multiple points on the network) followed intrinsic head-outflow relationship of each node. By comparing the experimentally obtained head-outflow relationship with various HOR equations proposed by previous studies, the one proposed by Wagner et al. showed the best agreement with the exponential parameter, m of 3.0.

Extraction of Water Body Area using Micro Satellite SAR: A Case Study of the Daecheng Dam of South korea (초소형 SAR 위성을 활용한 수체면적 추출: 대청댐 유역 대상)

  • PARK, Jongsoo;KANG, Ki-Mook;HWANG, Eui-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.41-54
    • /
    • 2021
  • It is very essential to estimate the water body area using remote exploration for water resource management, analysis and prediction of water disaster damage. Hydrophysical detection using satellites has been mainly performed on large satellites equipped with optical and SAR sensors. However, due to the long repeat cycle, there is a limitation that timely utilization is impossible in the event of a disaster/disaster. With the recent active development of Micro satellites, it has served as an opportunity to overcome the limitations of time resolution centered on existing large satellites. The Micro satellites currently in active operation are ICEYE in Finland and Capella satellites in the United States, and are operated in the form of clusters for earth observation purposes. Due to clustering operation, it has a short revisit cycle and high resolution and has the advantage of being able to observe regardless of weather or day and night with the SAR sensor mounted. In this study, the operation status and characteristics of micro satellites were described, and the water area estimation technology optimized for micro SAR satellite images was applied to the Daecheong Dam basin on the Korean Peninsula. In addition, accuracy verification was performed based on the reference value of the water generated from the optical satellite Sentinel-2 satellite as a reference. In the case of the Capella satellite, the smallest difference in area was shown, and it was confirmed that all three images showed high correlation. Through the results of this study, it was confirmed that despite the low NESZ of Micro satellites, it is possible to estimate the water area, and it is believed that the limitations of water resource/water disaster monitoring using existing large SAR satellites can be overcome.

Comparative evaluation for leaf position accuracy according to gantry angle variation in MLC quality assurance using electronic portal imaging device(EPID) and GafChromic EBT3 film (전자포탈영상장치(EPID)와 GafChromic EBT3 film을 이용한 다엽콜리메이터 정도관리 시 갠트리 각도 변화에 따른 엽의 위치 정확성 비교 평가)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Lee, Sun Young;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the error of the leaf position accuracy of the MLC due to the gravity effect according to the gantry angle by using picket fence test using EPID and GafChromic EBT3 film. Materials and Methods: A 5 cm solid phantom was placed on the table and the SAD was set to 100 cm. The EBT3 film was placed exactly over the solid phantom and covered a 1.5 cm solid phantom and the picket fence test was performed. The EPID was measured under the same conditions as the EBT3 film at SID 100 cm. The gantry angles were measured at $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ and $270^{\circ}$ in order to evaluate the position of the MLC according to the gantry angle. For the geometric evaluation of the MLC, the leaf position accuracy of the MLC was analyzed using the analysis program. Results: In case of EPID, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.18 mm, 0.31 mm, 0.20 mm, 0.26 mm on the average and the maximum values of the errors were respectively 0.44 mm, 0.54 mm, 0.34 mm, 0.44 mm. In case of EBT3 film, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.19 mm, 0.21 mm, 0.19 mm, 0.31 mm on the average and the maximum values of the errors were respectively 0.35 mm, 0.45 mm, 0.36 mm, 0.48 mm. Conclusion: In this study, we analyzed the position error of the leaf of the MLC according to the gantry angle, and confirmed the position error of the leaf by gravity effect. As a result of comparing the leaf position accuracy using EPID and EBT3 film according to the variation of gantry angle, a larger error occurred in the error analysis method using EPID than that of EBT3 film. Therefore, in the case of IMRT based on MLC, as well as verification of accurate dosimetry should be conducted, it is considered that the quality control and verification for the precise operation of the MLC will be needed. and it is necessary to compare and verify the method of analysis.

  • PDF

Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker (인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고)

  • Chae, Seung-Hoon;Park, Jang-Pil;Lee, Yang-Hoon;Yoo, Suk-Hyun;Seong, Won-Mo;Kim, Kyu-Bo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • Purpose: In this study, we considerate our radiation therapy process for the breast cancer patient implanted a pacemaker applying the machine movement surgery, shielding, beam selection. Materials and Methods: We perform radiation therapy to a 54 years old, breast cancer patient implanted a pacemaker. The patient underwent a surgery to move the position of a pacemaker to right side breast after consultation with cardiology department. Prescribed dose was 5,040 cGy and daily dose 180 cGy for 28 fractions. The 10 MV photon energy, field size 0/$9.5{\times}20$ cm, half beam and opposing portal irradiation are used. To find out appropriate thickness of shielding board, we carried out an experiment using a solid water phantom ($30{\times}30{\times}7$ cm), a Farmer-type chamber (TN30013, PTW, Germany) and a shielding board (Pb $28{\times}27{\times}0.1$ cm). We calculated expected absorbed dose to te pacemaker with absorb ratio and shielding ratio. In the PTP system (Eclipse, Varian, USA), we figured out how much radiation would be absorbed to the machine with and without shielding. First day of the radiation therapy, we measured head scatter to the pacemaker with MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada). Results: In the phantom measurement, we found out appropriate thickness was 2 mm of shielding board. In the RTP, when using 2 mm shielding the pacemaker will be absorbed 11.5~38.2 cGy and DVH is 77.3 cGy. In the first day of the therapy, 4.3 cGy was measured so 120.4 cGy was calculated during total therapy. The patient was free from any side effects, and the machine also normally functioned. Conclusion: As the report of association which have public confidence became superannuated, there is lack of data about new machine. We believe that radiation therapy to thiese kind of patients could be done successfully with co-operation, patient-suitable planning, accurate QA, frequent in-vivo dosimetry and monitoring.

  • PDF