교류 급전시스템 성능검증을 위한 시험방안에 관한 연구 (A Study on tests process for verification of AC Traction system performance)

  • 정호성;이기원;김주락;한문섭;김진희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2202-2203
    • /
    • 2011
  • AC substation of urban transit supplies a suitable AC power on electricity vehicles. AC substation is verified electrical safety of system through pre-operation inspection on electrical installations to be supplied power from KEPCO. However, because test items and method for AC traction system are unprepared on pre-operation inspection, the general safety and performance verification of AC traction system are very insufficient. Therefore this paper analyze the test examples such as factory equipment tests, factory combined tests and railway tests for the safety and performance verification of AC traction system and present a suitable test items and test standard in domestic.

  • PDF

중국 위성요격실험의 의의와 영향에 따른 우주자산 보호방안 연구 (Study on the protection measures for space assets with the consideration of Chinese ASAT Test)

  • 공현철;송병철;서윤경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.479-484
    • /
    • 2007
  • Recently China has carried out a successful anti-satellite missile test at more than 850km altitude January 11 destroying an aging Chinese weather satellite target with a kinetic kill vehicle launched on board a ballistic missile. Korea has developed scientific and commercial satellites and sounding rockets from 1990s. As the fear of the militarisation of space becomes the reality, we need to consider the safety of our space assets from the perspectives of design, operation, and policy. In this paper we study on the general meanings and impacts of Chinese anti-satellite missile test and the measure to protect our space assets from the points of the design, operation and policy.

  • PDF

네트워크 기반 제어시스템의 통신부하 시험방법 (Traffic Test Method for Networked Control System)

  • 유광명;김종안;류호선
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.688-695
    • /
    • 2013
  • Networked Control Systems(NCS) contain the structure which controllers, actuators and sensors are connected to communication network. And they have been adopted in large and complicated plant area due to the advantages of mitigating computational bottleneck and maintenance. Although this structure provides many benefits, it brings in problems of unpredictable communication delay, data loss and corruption. This phenomena have to be considered in designing NCSs since it affects on overall control system stability. This paper introduces network traffic test method for ethernet based NCSs to find out maximum network usage which guarantee stable control operation. Test results shows this methods can be adopted in various types of NCSs and contributes economical system design and effective system operation.

천리안 위성을 활용한 위성 통신용 공공 테스트베드 운용에 관한 연구 (A Study of Public Test-bed Operation for Satellite Communications via COMS)

  • 왕도휘;오덕길
    • 한국위성정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.12-16
    • /
    • 2013
  • 본 논문에서는 현재 운용중인 천리안 위성을 활용한 위성 통신용 공공 테스트베드 시스템 구성 및 서비스 이용 현황에 대해 소개하고자 한다. 공공 시범 서비스 운용을 통해 차세대 VSAT 서비스 제공 시 Ka 대역의 활용도가 높아짐에 따른 광대역 멀티미디어 서비스가 가능할 것으로 된다. 또한, 향후 위성을 통한 UHD 방송을 통해 방송서비스의 보편적 접근성 향상을 예상해 본다.

한국형 고속열차를 활용한 기존선 전철화 구간에서 고속열차 운행의 적합성 평가 (Test and evaluation on the suitability of operating high speed train in electrified conventional line through test run of HSR-350x)

  • 목진용;김영국;김기환;조민영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.229-235
    • /
    • 2007
  • The KTX, which have opened the revenue service in April 2004, is operating in Kyoung-Bu high-speed line and electrified conventional Ho-Nam line, and the more the electrification are enlarged, the more the requirement of operating of high speed train would be increased. In this paper, the result of test run and evaluation on the suitability of operating high speed train in electrified conventional line between Dae-jeon and East Dae-gu was reviewed. Evaluation and analysis was executed in specific categories, such as operation & running performance of the train considering vibration characteristics based on UIC 518, ride comfort and current collection, and response sensitivity of ATS device for signalling from track facility. The result of this running test was evaluated and considered as a good practice for revenue operation of high speed train in electrified conventional line between Dae-jeon and Dae-gu.

  • PDF

직류 급전시스템 성능검증을 위한 시험방안 분석 (An analysis of tests process for verification of DC Traction system performance)

  • 정호성;한문섭;장동욱;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.499-504
    • /
    • 2008
  • DC substation of urban transit supplies a suitable DC power on electricity vehicles by being supplied from KEPCO. DC substation is verified electrical safety of system through pre-operation inspection on electrical installations to be supplied power from KEPCO. However, because test items and method for DC traction system are unprepared on pre-operation inspection, the general safety and performance verification of DC traction system are very insufficient. Therefore this paper analyze the overseas test examples such as factory equipment tests, factory combined tests and railway tests for the safety and performance verification of DC traction system and present a suitable test items and test standard in domestic.

  • PDF

Development and High Power RF Test of the Vacuum Feedthrough for KSTAR ICRF Antenna

  • Bae, Young-Dug;Hwang, Churl-Kew;Kwak, Jong-Gu
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.211-217
    • /
    • 2002
  • A 1-MW vacuum feedthrough for the KSTAR ICRF antenna is fabricated and high power RF test is performed. It is designed to have two alumina $(Al_2O_3)$ ceramic cylinders and O-ring seal instead of a brazed seal for good mechanical and thermal strength, which is important in long pulse or steady state operation. For cooling of the ceramics, dry air is circulated in a space between the two cylinders and the outer conductor. Independent cooling water channels are installed to cool the inner conductor of the feedthrough. RF high voltage test is performed using two kinds of ceramics with the purities of 99.7% and 97%. Stable operation is possible with the RF voltage of 30 kVp at long pulse of 300 sec without any severe damage.

대학치과병원 예방치과운영 전·후의 환자진료행태와 진료비용 변화 (Changes in treatment behavior and cost according to the operation of preventive dentistry in university dental hospital)

  • 홍효경;최성우
    • 한국치위생학회지
    • /
    • 제20권5호
    • /
    • pp.707-716
    • /
    • 2020
  • Objectives: This study aims to provide basic data for high-quality dental services. In addition, we will promote the operation of preventive dentistry that implements preventive measures. It was conducted to study the change of patient's treatment behavior and treatment cost due to the discontinuation of preventive dentistry in university dental hospitals. Methods: This study collected data using the integrated medical information system of the C University Dental Hospital. From September 1, 2017 to August 31, 2019, data were analyzed using frequency, percentage, mean, standard deviation, chi-square test using SPSS version 24.0 statistical program, and T-test. Results: There was a significant difference in the number of preventive dental treatment cases from 58.3% of preventive dental operation periods to 41.7% of preventive dental operation periods. As a result of comparing the medical expenses, the total medical expenses during the preventive dental operation period decreased from 521,308,872 won to 379,724,995 won during the discontinuation period, 141,583,877 won. The number of medical treatments by treatment behavior decreased 3,835 (28.4%) from a total of 13,520 preventive dental operation periods to 9,685. Conclusions: This study is meaningful as the first study to confirm the change in the treatment behavior and the change in the cost of treatment due to the discontinuation of the operation of preventive dentistry at university dental hospitals. In conclusion, it is thought that there is a possibility of the lack of accessibility and the limitation of professional preventive care due to the discontinuation of preventive dentistry.

분진 및 풍속에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구 (A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust and Wind Velocity)

  • 이춘하;이호성;김시국
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.50-57
    • /
    • 2017
  • 본 논문은 분진 및 풍속에 따른 연기감지기 챔버의 응답특성에 관한 연구이다. 연기감지기가 실내에 적용됨으로 인해 화재의 조기감지 측면에서는 나아졌으나, 실내에서 발생되는 다양한 생활먼지 및 환경적인 요건 등에 의해 발생될 수 있는 부작동 및 오작동에 대한 연구는 미비한 편이다. 이에 본 연구에서는 다양한 분진 및 풍속에 따른 연기감지기의 실내적응성을 연구하기 위해 연기챔버의 형태 및 구조가 다른 4종류의 광전식연기감지기를 실험대상으로 하고, 플라이애시, 활석가루 그리고 섬유분진(흑채가루)을 실험시료로 하여 분진시험을 진행하였다. 또한 연기챔버 내의 오염도에 따른 응답특성을 관찰하기 위해 추가적으로 분진시험 풍속을 0.25 m/s, 0.5 m/s, 1.0 m/s로 설정하여 인가하였다. 실험결과 플라이애시 및 활석가루, 섬유분진의 경우 분진시험 기준풍속조건인 0.25 m/s에서는 분진인가 후 작동시험 및 부작동시험에서 모두 적합한 것으로 나타났다. 반면, 가혹풍속조건인 0.5 m/s 및 1.0 m/s에서는 플라이애시 및 활석가루의 경우 부작동시험에서 비화재보인 오작동이 나타났고, 섬유분진의 경우 작동시험에서 정상적으로 작동되지 않아 부작동이 발생하는 것으로 확인되었다.

발사체 구성품 및 시스템의 공압시험 (Pneumatic Test of Components and Systems of Launch Vehicle)

  • 임하영;한상엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.904-907
    • /
    • 2011
  • Various types of gases and propellants are used in launch vehicle. In order to fulfill the mission of the launch vehicle, the components and systems used in launch vehicle should ensure flawless operation in these environments. The pneumatic test is the test performed using compressed gas to prove requirements of the components and systems. This paper describes the requirements of the gas quality for pneumatic test, leak test method, and pneumatic test of the launch vehicle.

  • PDF