• Title/Summary/Keyword: Operation Problem

Search Result 3,648, Processing Time 0.031 seconds

A LOW-COST PROTOCOL IN SENSOR NETWORK UBIQUITOUS ENVIRONMENT

  • Lee Dong-heui;Cho Young-bok;Kim Dong-myung;Lee Sang-ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.766-769
    • /
    • 2005
  • In a ubiquitous environment made up of multiple sensors, most sensors participate in communications with limited battery, and the sensor node isn't able to participate in communications when all the battery is used up. When an existing authentication method is used for the sensor node which has to participate in a long term communication with limited battery, it creates a problem by making the length of network maintenance or sensor node's operation time relatively shorte. Therefore, a network structure where RM (Register Manager) node and AM (Authentication Manager) node are imported to solve the energy consumption problem during a communication process is presented in this thesis. This offers a low power protocol based on safety through a mutual authentication during communications. Through registration and authentication manager nodes, each sensor nodes are ensured of safety and the algorithm of key's generation, encryption/descramble and authentication is processed with faster operation speed. So the amount of electricity used up during the communications between sensor nodes has been evaluated. In case of the amount of electrical usage, an average of $34.783\%$ for the same subnet and 36.855 for communications with two different subnets, are reduced. The proposed method is a protocol which maintains the limited battery for a long time to increase the effectiveness of energy usage in sensor nodes and can also increase the participation rate of communication by sensor nodes.

  • PDF

An Intelligent Agent Based Supply Chain Operation Architecture under Adaptive Relationship between Multiple Suppliers and Customers (다수 수요자-공급자간 적응적 협력관계하의 지능형 에이전트 기반 공급망운영 구조)

  • 윤한성
    • Journal of Intelligence and Information Systems
    • /
    • v.9 no.1
    • /
    • pp.109-123
    • /
    • 2003
  • The relationship between suppliers and customers is treated importantly not only in the traditional business-to-business (BtoB) commerce but also in today's Internet environments. On the one hand, most of Internet-based BtoB commerce services like customer-centric e-procurement, supplier-centric e-sales or intermediary-centric e-marketplace focus mainly on the selection of partners according to bidding, auction, etc. This point may result in the problem of overlooking the relationships between suppliers and customers. To overcome this problem in this paper, an intelligent agents-based supply chain operation architecture is proposed and appraised considering the relationship and its adaptation.

  • PDF

Assessment of Fatigue and Fracture on a Tee-Junction of LMFBR Piping Under Thermal Striping Phenomenon

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Bong Yoo
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.267-275
    • /
    • 1999
  • This paper deals with the industrial problem of thermal striping damage on the French prototype fast breeder reactor, Phenix and it was studied in coordination with the research program of IAEA. The thermomechanical and fracture mechanics evaluation procedure of thermal striping damage on the tee-junction of the secondary piping using Green's function method and standard FEM is presented. The thermohydraulic(T/H) loading condition used in the present analysis is the random type thermal loads computed by T/H analysis on the turbulent mixing of the two flows with different temperatures. The thermomechanical fatigue damage was evaluated according to ASME code section 111 subsection NH. The results of the fatigue analysis showed that fatigue failure would occur at the welded joint within 90,000 hours of operation. The assessment for the fracture behavior of the welded joint showed that the crack would be initiated at an early stage in the operation. It took 42,698.9 hours for the crack to propagate up to 5 mm along the thickness direction. After then, however, the instability analysis, using tearing modulus, showed that the crack would be arrested, which was in agreement with the actual observation of the crack. An efficient analysis procedure using Green's function approach for the crack propagation problem under random type load was proposed in this study. The analysis results showed good agreement with those of the practical observations.

  • PDF

A Study on Optimal Electric Load Distribution and Generator Operating Mode Using Dynamic Programming (동적계획법을 이용한 발전기의 운전모드 및 최적부하 배분에 관한 연구)

  • H-H Yoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.313-319
    • /
    • 2002
  • Since the oil crisis in 1970, a great deal of effort has been made to develop automatic electric load sharing systems as a part of the efforts to save energy. A large scale electric generating system composes more than two generators whose characteristics may be different. When such a system is operated individually or in parallel, the lagrange multiplier's method has difficulty in achieving optimal load distribution because generators usually have the limitations of the operating range with inequality constraints. Therefore, a suitable operating mode of generators has to be decided according to the selection of the generators to meet electric power requirements at the minimum cost. In this study, a method which solves the optimal electric load distribution problem using the dynamic programming technique is proposed. This study also shows that the dynamic programming method has an advantage in dealing with the optimal load distribution problem under the limitations of the operating range with inequality constraints including generator operation mode. In this study, generator operating cost curve of second order equation by shop trial test results of diesel generators are used. The results indicate that the proposed method can be applied to the ship's electric generating system.

A Study on the Forestry Safety Helmet Development Based on IoT (IoT 기반 임업용 안전모 개발에 관한 연구)

  • Nam, Ki-Hun;Park, Jung-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.419-425
    • /
    • 2020
  • There are many accident risks in logging operation of forestry such as struck by felled trees and caught in, under, or between felled trees. These accidents are primarily occurred by not keeping a safe distance between workers. According to the forestry safety instruction, workers are not supposed to go into the safety zone which is a circle with a radius of more 2 times the height of felling tree. However, this rule does not keep because of poor safety consciousness, poor sight and extreme noise of logging operation machines. This problem causes many major accidents every year. To solve this problem, we made forestry safety helmets based on IoT technology. These helmets have functions to make a visual and an acoustic alarm signal when reach the distance between workers within 20 meters. We developed the algorithm to operate the helmet's functions and conducted tests to check the functions. As a result of tests, we assured the normal system operating conditions.

Surgical Intervention of the Complications of Cardiac Catheterization (외과적 치료가 필요했던 심도자 합병증에 대한 임상적 고찰)

  • Lee, Young;Park, Kyung-Sin;Park, Jin-Seog;Lim. Seung-Pyung;Kim, Eung-Joong
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.606-609
    • /
    • 1995
  • We have experienced ten cases of emergent operation for the complications of cardiac catheterization during the period from 1985 to September 1994.Catheterization was done for the evaluation of the cardiac or vascular problem in 8 cases and 2 cases of neurosurgical problem. The extracardiac injection of contrast material have occurred in 3 cases[primum ASD,Trilogy,VSD . Six cases were unable to remove the catheter from femoral artery or vein. The catheters were knotted, coiled, impacted or broken. An embolectomy was done 40 years old man who suffered from chronic left subclavian artery obstruction a day after angiography. Open heart surgery was performed in 5 cases of cardiac perforation,impacted catheter in left inferior pulmonary vein and broken catheter of VSD. Arteriotomy was done in 4 cases to remove the knotted and coiled catheter. There was no complication or mortality for the emergent operation.

  • PDF

Control Scheme Using Active Power Regulation for DC Voltage of VSC HVDC Under Unbalanced Voltage (불평형 전압 발생 시 유효전력 조절을 통한 전압형 HVDC의 DC전압 제어 방안)

  • Park, Sang-In;Huh, Jae-Sun;Moon, Won-Sik;Kim, Doo-Hee;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.232-239
    • /
    • 2015
  • Faced with unbalanced grid operation mode, the high voltage direct current (HVDC) based on voltage source converter (VSC) can be properly controlled by a dual current control scheme. For the modular multilevel converter (MMC) controlling the AC side current is able to limit the arm current which flows along the IGBT of submodule (SM) to rated current. However the limitation of the arm current results in leaving the control range of active power at MMC confined to below the rated capacity. As a result, limiting the arm current causes the problem that the DC side voltage of the HVDC can not be controlled to the reference value since MMC HVDC adjusts the DC side voltage through the active power. In this paper, we propose the algorithm adjusting the active powers of both MMCs to resolve the problem. The back-to-back MMC HVDC applying the algorithm is modeled by PSCAD/EMTDC to verify the algorithm.

A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed (Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

Improvement of Low Speed Operation Characteristic of DC Servo Motor Using a Fuzzy Tuning Speed Observer (퍼지동조 속도관측기를 이용한 직류서보전동기의 저속운전 특성 개선)

  • Ahn, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.244-249
    • /
    • 2008
  • This paper deals with speed control of DC servo motor using a Fuzzy tuning observer. Speed sensor detect a speed of rotor continuously. But it have a limit as a driving speed to detect speed precisely. So it is problem to improve the performance of the driving system. To solve the problem, it is studied to detect a speed of DC motor without sensor. In particular, study on the method to estimate the speed using the observer is performed a lot. In this parer, the gain of the observer is properly set up using the fuzzy observer. The fuzzy observer has a superior transient characteristic and is easy to implement compared the existing method is designed. It estimate the derivative of the armature current directly using the armature current measured in the DC motor. It estimate the speed of the rotor using the differentiation. It is proposed speed sensorless control method using the estimated speed. Optimal gain of Luenberger observer is set up using the fuzzy observer and adapted speed control of DC servo motor low speed operation. It is proved excellence and feasibility of the presented observer from the comparison tested a case with a speed sensor and a case without a speed sensor which used a highly efficient drive and 200W DC servo motor starting system.

A Study on the Information Exchange Technology Between IEDs Using SOAP in Network Based Substation Automation System (네트워크 기반 자동화 변전소에서 SOAP을 이용한 IED간 정보교환기술 연구)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.376-383
    • /
    • 2006
  • In this paper, autonomous information exchange methodology is studied between IEDs using SOAP protocol based on XML and PtP communication to archive the safety and reliability of large-scale system operation. The SOAP protocol has the advantages in the independency Problem for operating systems, using language, platforms and the security problem because it is XML-based RPC protocol. Inference-based solution of the IED is designed as rule-based solution so that the IED internal status, the system status or the faulted zone can be inferred autonomously using the internal data as well as information data obtained from free information exchange among other IEDS, Also, it is designed so that the inference results and the operation information are transmitted to the above SCADA system, and determined autonomously whether the commands from the SCADA are executed or not. Finally, The inference-based solution of IED and information exchange system among IEDS is implemented using MS Visual C++ MFC, MS SOAP and MS XML. Availability and accuracy of the proposed methodology and the design is verified from diversity simulation reviews for typical distribution substation.