• 제목/요약/키워드: Operating voltage

검색결과 2,347건 처리시간 0.033초

전력계통의 전압 붕괴 방지를 위한 인텔리젼트 시스템 (An Intelligent System to Prevent Voltage Collapse for A Power system)

  • 김재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권10호
    • /
    • pp.472-479
    • /
    • 2001
  • In order to prevent voltage collapse. this paper introduces the idea of the intelligent system and operating polices for a power system, then presents the results of voltage stability studies for that power system. The intelligent system includes a dedicated computer doing calculation and evaluation jobs and several intelligent relays serving as last guards to carry out the pre-set remedies. In the intelligent system, P-V curves are used to determine the operating margin from the current operating point to the maximum operating point, or the nose point. This paper suggests an operating guide for voltage stability of a power system. The effectiveness of location ad amount of load shedding for the different power load models are studied.

  • PDF

Operating Voltage of Optical Instruments based on Polymer-dispersed Liquid Crystal for Inspecting Transparent Electrodes

  • Yeo, Sunggu;Oh, Yonghwan;Lee, Ji-Hoon
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.45-50
    • /
    • 2017
  • Optical instruments based on polymer-dispersed liquid crystal (PDLC) have been used to inspect transparent electrodes. Generally the operating voltage of an inspection instrument using PDLC is very high, over 300 V, reducing its lifetime and reliability. The operating-voltage issue becomes more serious in the inspection of touch-screen panel (TSP) electrodes, due to the bezel structure protruding over the electrodes. We have theoretically calculated the parameters affecting the operating voltage as a function of the distance between the TSP and the PDLC, the thickness, and the dielectric constant of the sublayers when the inspection module was away from the TSP electrodes. We have experimentally verified the results, and have proposed a way to reduce the operating voltage by substituting a plastic substrate film with a hard coating layer of smaller thickness and higher dielectric constant.

직류가선전압 모의장치를 적용한 지하철용 회생인버터 시스템 (Regenerative Inverter System for Railway with DC Line Voltage Simulator)

  • 지용혁;조기현;장수진;원충연;김용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1515-1521
    • /
    • 2007
  • In this paper, a unified regenerative inverter system for railway with DC line voltage simulator is proposed. In order to determine the operation characteristics of the regenerative inverter, the DC line voltage simulator is proposed. The DC line voltage simulator, which is based on the AC-DC PWM converter, varies the DC voltage according to the fluctuating voltage which is measured in the actual DC line. The suitable operating point of the regenerative inverter can be estimated from the simulation result. The regenerative inverter operates two modes. When the DC line voltage exceed the operating point, already set up, it works as regenerative inverter to return the excessive power of DC line to the grid. When the DC line voltage is under the operating point, it works as active power filter to compensate harmonic currents. In this paper, the control algorithm of the DC line voltage simulator and that of the regenerative inverter is proposed.

  • PDF

순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;정성원;김재현;이근준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

전압품질이 저압 전기기기 운전에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.33-35
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석 (Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable)

  • 진혜영;이종범;김영;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

고농도의 Mg가 도핑된 GaN층을 이용한 GaN계 청자색 레이저다이오드의 동작 전압 감소 (Reduction of Operating Voltage of GaN-based Blue-violet Laser Diode by using Highly Mg Doped GaN Layer)

  • 곽준섭
    • 한국전기전자재료학회논문지
    • /
    • 제17권7호
    • /
    • pp.764-769
    • /
    • 2004
  • In order to reduce operating voltage of the GaN based blue-violet laser diodes, the effect of highly Mg doped GaN layer, which was grown below ohmic contact metals, on contact resistivity as well as operating voltage has been investigated. The addition of the highly Mg doped GaN layer greatly reduced contact resistivity of Pd/Pt/Au ohmic contacts from $5.2 \times {10}^-2 \Omegaㆍ$\textrm{cm}^2$ to 7.5 \times {10}^-4 \Omegaㆍ$\textrm{cm}^2$$. In addition, it also decreased device voltage at 20 mA by more than 3 V. Temperature- dependent sheet resistivity of the highly Mg doped GaN layer suggested that the reduction of the contact resistivity could be attributed to predominant current flow at the interface between the Pd/Pt/Au contacts and p-GaN through a deep level defect band, rather than the valence band.

Assistive Circuit for Lowering Minimum Operating Voltage and Balancing Read/Write Margins in an SRAM Array

  • Shin, Changhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.184-188
    • /
    • 2014
  • There is a trade-off between read stability and writability under a full-/half-select condition in static random access memory (SRAM). Another trade-off in the minimum operating voltage between the read and write operation also exists. A new peripheral circuit for SRAM arrays, called a variation sensor, is demonstrated here to balance the read/write margins (i.e., to optimize the read/write trade-off) as well as to lower the minimum operation voltage for both read and write operations. A test chip is fabricated using an industrial 45-nm bulk complementary metal oxide semiconductor (CMOS) process to demonstrate the operation of the variation sensor. With the variation sensor, the word-line voltage is optimized to minimize the trade-off between read stability and writability ($V_{WL,OPT}=1.055V$) as well as to lower the minimum operating voltage for the read and write operations simultaneously ($V_{MIN,READ}=0.58V$, $V_{MIN,WRITE}=0.82V$ for supply voltage $(V_{DD})=1.1V$).

가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰 (Optimization of DC Operating Voltage for GDT-Adopted SPD)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.