• 제목/요약/키워드: Operating standard speed

검색결과 148건 처리시간 0.023초

國産 디이젤機關의 汚染物質 排出特性에 關한 硏究 (A Study on Characteristics of Exhaust Emissions from Domestic Used Diesel Engines)

  • 趙康來;金良均;董宗仁;嚴明道
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.83-92
    • /
    • 1985
  • In odrder to survey the emission level of air pollutants from diesel vehicles, was measured CO, HC, NOx and smoke of 4 types of domestic-use diesel engines under various conditions. The emission of CO, HC and NOx tested by 6-Mode test method and smoke emission by full load test met the permissible vehicle emission standard. Pollutant emission rates of diesel engines were different according to engine operating conditions, that is, engine load and engine speed. Generally, CO and HC was emitted more at low load and NOx at high load but the trend was quite different by the type of engines. In exhaust gas, $NO_2$ portion of NOx emission was high, specially at low speed and low load. The correlation equation between CLD(NOx) and NDIR(NO) method of nitrogen of nitrogen oxides analysis was y = 1.10x - 3.48 (y: CLD method) as a result of 6-mode test.

  • PDF

유압베인펌르 내부 회전체의 역학적인 거동 (The Dynamic Behavior of Internal Rotating Slider of Oil Hydraulic Vane Pump)

  • 김장현;정재윤
    • Tribology and Lubricants
    • /
    • 제6권2호
    • /
    • pp.43-49
    • /
    • 1990
  • The Dynamic Behavior in line contacts between the vane tip and camring in an oil hydraulic vane pump with intravanes has been investigated. Variations of the radial acting force of a vane were calculated from previously measured results of dynamic infernal pressure in four chambers surrounding a vane, and variations of the behavior were estimated in both the rotational speed range from 1200 to 2700 rpm and in the delivery pressure range from 10 to 21Mpa. The results indicate the variations of the radial acting force. Under the standard operating condition (to 14 Mpa, 1800 rpm), the radial acting force on the vane is governed by internal dynamic pressures, but it is more influenced by rotating speed at higher than 2000 rpm relatively.

자동차용 아연도금강판의 심 용접조건과 용접성에 관한 연구 (A Study on the Welding Conditions of Weldability of Team Welding for Galvanized Steel Sheets of Automotive)

  • 임재규;정균호;국중하
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.27-32
    • /
    • 2001
  • This paper is studied about welding conditions and weldability of seam welding for galvanized steel sheet of automotive. The fuel tank of automobile is made by seam welding to be required of airtight or oiltight. This method have required a short time for welding, simplicity operation progress and little HAZ. Especially, it has more less residual stress and transformation than different welding progress. So, this study is for decreasing the leakage occurrence rate and to make standard operating condition table anyone can operate easily. Therefore, this study is analyzed the optimum conditions of seam welding for making the automobile with galvanized steel sheets by means of observing the microstructure and configuration back projection, RT, tensile-shear strengths test and SEM. Optimum conditions of seam welding obtained as follows, current 17.2-17.6kA speed 1.0m/min weld time 4:10:6 and current 16.5-17.4kA, speed 0.83m/min, weld time 4:10:4 at t1.0, and current, 18.5-18.9kA, speed 0.8m/min, weld time 4:10:4 and current 16.5-17.4kA, speed 0.68m/mi, weld time 4:10:2 at t1.6.

  • PDF

해외 수력발전설비 성능평가설비 및 평가 방법 (Performance evaluation facilities and evaluation methods for hydropower equipment)

  • 김영준;김용열;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.194-194
    • /
    • 2010
  • The variable demand on the energy market, as well as the limited energy storage capabilities, requires a great flexibility in operating hydraulic turbines. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and/or maximum steady-state runaway speed, as well as guarantees related to cavitation. Performance test are conducted by the test standard. Test codes based on extensive research data are written under the leadership of an IEC. Performance evaluation is carry out several test(performance test, cavitation test and runaway test). The paper presents the international turbine test laboratory and performance test standard.

  • PDF

VOF 다상유동 해석을 이용한 침사지 유동특성 연구 (Study on flow characteristics of the grit chamber using VOF multi-phase flow simulations)

  • 윤정환
    • 한국가시화정보학회지
    • /
    • 제19권2호
    • /
    • pp.63-73
    • /
    • 2021
  • It is essential to accurately predict the change in water level, velocity, and flow rate for each passage of the grit chamber according to the operating conditions of the pump. In this study, VOF multiphase flow analysis was performed, and the flow characteristics of the grit chamber were predicted. As a result of simulations, the sedimentation phenomenon after the entrance of the grit chamber channel is expected to occur on the side walls. When 6 channels are used, the average speed of the channels is about 52% of the design standard, and when 4 channels are used, the value increases to 74% of the design standard. The average water level in the channels tends to decrease as the flow velocity increases, and the water level in the absorption well with a larger flow rate is maintained lower than that in the absorption well with a smaller flow rate.

접이식 고속열차 승강문 스텝의 안전성 확인을 위한 해석적 연구 (Analytical Study to Check Safety of Folding-type Staircase in High Speed Rolling Stock)

  • 이원대;박상규;이경규;이정훈
    • 한국철도학회논문집
    • /
    • 제17권2호
    • /
    • pp.87-93
    • /
    • 2014
  • 국내에서 운행중인 프랑스 알스톰에서 도입된 고속철도차량인 KTX의 승강문 접이식 발판이 유럽 표준 규격인 EN14752를 따르고 있으나 접이식 스텝 동작 시 발판 형성 폭이 200mm가 되어 국내 20세에서 60세의 발평균 사이즈인 253mm에 미치지 못하고 있다. 신체구조 상 신체 하중은 발 뒤축에 대부분 걸리므로 현재의 발판은 승하차 시 전도나 미끄러짐이 발생 할 수 있는 위험이 존재하고 있으며, 실제 발생을 하고 있다. 이에 기존 차량 조건 내에서 발판의 폭을 확대하여 스텝 개념설계(안)의 구조해석을 수행하고 이의 안전성을 검토하였다.

Progress of High-k Dielectrics Applicable to SONOS-Type Nonvolatile Semiconductor Memories

  • Tang, Zhenjie;Liu, Zhiguo;Zhu, Xinhua
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권4호
    • /
    • pp.155-165
    • /
    • 2010
  • As a promising candidate to replace the conventional floating gate flash memories, polysilicon-oxide-nitride-oxidesilicon (SONOS)-type nonvolatile semiconductor memories have been investigated widely in the past several years. SONOS-type memories have some advantages over the conventional floating gate flash memories, such as lower operating voltage, excellent endurance and compatibility with standard complementary metal-oxide-semiconductor (CMOS) technology. However, their operating speed and date retention characteristics are still the bottlenecks to limit the applications of SONOS-type memories. Recently, various approaches have been used to make a trade-off between the operating speed and the date retention characteristics. Application of high-k dielectrics to SONOS-type memories is a predominant route. This article provides the state-of-the-art research progress of high-k dielectrics applicable to SONOS-type nonvolatile semiconductor memories. It begins with a short description of working mechanism of SONOS-type memories, and then deals with the materials' requirements of high-k dielectrics used for SONOS-type memories. In the following section, the microstructures of high-k dielectrics used as tunneling layers, charge trapping layers and blocking layers in SONOS-type memories, and their impacts on the memory behaviors are critically reviewed. The improvement of the memory characteristics by using multilayered structures, including multilayered tunneling layer or multilayered charge trapping layer are also discussed. Finally, this review is concluded with our perspectives towards the future researches on the high-k dielectrics applicable to SONOS-type nonvolatile semiconductor memories.

토양 분진발생장치의 개발과 평가 (Development and Evaluation of a Dust Generator Using Soil Samples)

  • 이지연;이기영
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.383-390
    • /
    • 2010
  • Exposure to fugitive dust can contribute to several respiratory health problems, and proper sampling of fugitive dust is necessary to assess exposure. However, field sampling of soil dust encounters problems from spatial and temporal differences in soil properties, field operations, and meteorological conditions. To minimize these problems, we designed a dust generator that simulates dust generation from soil. The dust generator consisted of a rotating chamber where soil samples were loaded and tumbled, and a settling chamber, where airborne soil dust samples were collected. As standard operating conditions, we decided on 2 g soil mass, 10 min sampling time, and 20 rpm rotating speed, with a flow rate of 30 l/min, based on three common soil textures of loam, sandy loam and silt loam. To evaluate optimal operating conditions, we used mixtures of Joomoonjin silica sand and clay. Although the average $PM_{10}$ concentration of Joomoonjin silica sand was low, dust concentrations were increased by an increased content of clay. The dust concentrations were consistent across repeated experiments, and showed similar concentration profiles during the sampling time with mixtures of clay and sand (coefficient of variation was $13.6{\pm}w;7.1%$). The results demonstrated that these standard operating conditions were suitable for the dust generator, which can be used to investigate variations in soil properties that affect dust production and potential potency of fugitive dust exposure.

CFD에 의한 2D 에어포일 공력특성 및 3D 풍력터빈 성능예측 (Predicting the Aerodynamic Characteristics of 2D Airfoil and the Performance of 3D Wind Turbine using a CFD Code)

  • 김범석;김만응;이영호
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.549-557
    • /
    • 2008
  • Despite of the laminar-turbulent transition region co-exist with fully turbulence region around the leading edge of an airfoil, still lots of researchers apply to fully turbulence models to predict aerodynamic characteristics. It is well known that fully turbulent model such as standard k-model couldn't predict the complex stall and the separation behavior on an airfoil accurately, it usually leads to over prediction of the aerodynamic characteristics such as lift and drag forces. So, we apply correlation based transition model to predict aerodynamic performance of the NREL (National Renewable Energy Laboratory) Phase IV wind turbine. And also, compare the computed results from transition model with experimental measurement and fully turbulence results. Results are presented for a range of wind speed, for a NREL Phase IV wind turbine rotor. Low speed shaft torque, power, root bending moment, aerodynamic coefficients of 2D airfoil and several flow field figures results included in this study. As a result, the low speed shaft torque predicted by transitional turbulence model is very good agree with the experimental measurement in whole operating conditions but fully turbulent model(${\kappa}-\;{\varepsilon}$) over predict the shaft torque after 7m/s. Root bending moment is also good agreement between the prediction and experiments for most of the operating conditions, especially with the transition model.

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.