• Title/Summary/Keyword: Ondol Heating System

Search Result 113, Processing Time 0.025 seconds

A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe (강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구)

  • Kim, Chang-Hee;Kim, Jong-Su;Woo, Jae-Ho;Kong, Sang-Wun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

Temperature Control of Ondol Indoor-Space (온돌 실내공간의 온도제어)

  • Shin, C.B.;Lee, J.W.;Sah, J.Y.;Lee, S.C.;Cho, S.H.;Suh, H.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.538-545
    • /
    • 1995
  • The heat transfer model of ondol heating system is derived in the linear form. The step responses of On-Off controller, PID controller and Position type fuzzy controllers are compared in the sense of several aspects : variation of temperature feedback variable, variation of supplied heat quantity by the boiler, variation of flow rate, variation of thickness of the base, variation of the outdoor temperature.

  • PDF

Proposing the Revision of Ondol Construction in the Standard Specification for Heritage Repair (문화재수리표준시방서의 온돌공사 개정 제안에 관한 연구)

  • Lim, Jun-Gu;Kim, Young-Jae
    • Journal of architectural history
    • /
    • v.32 no.5
    • /
    • pp.43-50
    • /
    • 2023
  • Ondol is a traditional underfloor heating system designated as a national intangible cultural heritage of Korea. The Cultural Heritage Administration (CHA) publishes a standard specification for the repair of cultural properties, including ondol. This standard specification is used as a guide for contractors who repair ondol in the field. However, the standard specification for ondol repair has some errors and is difficult to understand in the field. This paper proposes a revision of the standard specification for ondol repair. This study found that the standard specification for ondol repair has some problems in terms of the terminology and structure of ondol. These problems were sufficient to confuse ondol repairers in the field. Therefore, this study proposes to revise the standard specification to correct these errors and make it easier for ondol repairers in the field to understand. This study is expected to help recognize and preserve ondol as a cultural property and not just as a building.

A Study on the Estimation of Adhesive Stability of Organic.Inorganic Mixed Tile Bond to Ondol-Heating Floor System (온돌난방 바닥에 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착 안정성 평가연구)

  • Jung, Yang-Hee;Jung, Eun-Hye;Seo, Sin-Seok;Jeong, Jae-Soo;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.99-102
    • /
    • 2009
  • This paper is to present the performance data for pressure setting method using some tile bonds for application on the Ondol-Heating floor system. For this purpose, powder and liquid tile bonds(Organic.Inorganic mixed tile bonds) were compared with the conventional tile cement for pressure setting method in the sight of the adhesive stability of porcelain tile. It tested for tiles after 14, 28days under standard condition and severe conditions. The severe conditions were water immersion and heat ageing($70^{\circ}C$). Another experimental factors concerned tile bond properties such as mixing ratio(in case of using liquid admixture), open time, which are supposed to affect the tensile strength of tile, were studied and discussed through the experiments.

  • PDF

Analysis for Thermal Effect by an Unheated Housing Unit in Apartment (공동주택에서 비난방세대가 미치는 열적 영향)

  • Lee, Eun-Ju;Koo, Junemo;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

An Application of Shrinkage Compensation Mortar in Construction Field (수축 보상 모르타르의 현장 적용 연구)

  • 김기동;정성철;송명신;이경희
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.3-10
    • /
    • 2000
  • In this study, we compared a plain mortar with the CAS-system shrinkage compensation mortar for Ondol that is Korean traditional heating system. The Ondol mortar is necessary to have properties as non-crack, fine flatness and stability for thermal changes. especially, mortar'crack prevention is to be most important property in Ondol mortar. To develope the stable material on the crack-prevention, we used to calcium-sulfo-aluminate(CSA)system in shrinkage compensation mortar. And so, we confirmed the effects of calcium-sulfo-aluminate(CSA) system for mortar's physical properties such as setting time, compressive strength and expansion ratio for crack prevention. The initial and final setting time of the CSA mortar is faster than plain mortar about 2hours. And, Compressive strength increased about 20% that plain mortar. The crack length per unit area, plain mortar is 0.426∼0.481m/m2. The Results of apartment construction field test, the shrinkage compensation mortar is excellent about the crack-reduce effect.

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

Construction of Geum'yeok-dang, the Heung'hae Bae Clan House, and its Structural Changes during the Late Joseon Period -On the Architectural Ideology and Issue of Practicality- (흥해배씨 종가 금역당(琴易堂)의 건축과 조선후기의 구조 변화 -건축이념 및 실용성과 관련하여-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.4
    • /
    • pp.31-44
    • /
    • 2016
  • Geum'yeok-dang house in Andong was originally constructed in 1558. The original floor plan of the upper base featured a 90-degree tilted '日' shape, and had inner court(內庭) on each side of 'Jungdang(中堂, center hall)' building that was placed on the south-north axis. When designing the building, the Neo-Confucian client of Geum'yeok-dang applied his understanding of how Ga'rye("家禮") defined the structure of ritual space. Consequently, 'Daecheong(大廳)', the place where guests were greeted and ancestral rites and coming of age ceremonies for male were held, was built in a protruding fashion. 'Jungdang'[otherwise known as 'Jeongchim(正寢)'], where coming of age ceremonies for females were held, the master of the house faced death, and memorials for close ancestors were held, was placed at the center of the residence on the south-north axis. The Geum'yeok-dang today was greatly renovated in the early and mid 18th century, due to the spread of 'Ondol' heating system. As the Ondol heating system became popular, the pre-existing drawbacks and the inconvenience of the house stood out clearly. As a result, the house was renovated into today's structure consisting of '口' shape 'Anchae' and 'Daecheongchae' in separate building.

A Study on the Dwellings of Korean Diaspora in Yunhaju of Russia (러시아 거주 고려인의 주거에 관한 연구 -연해주 (Yunhaju: 연해주) 지역을 중심으로-)

  • 이영심;조재순
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.51-62
    • /
    • 2004
  • Koreans had started moving to Yunhaju in Russia for escaping from the tyrannical rule and famine in 1860's in Korea. It had been veiled and nearly known about Korean's life there because of social and political situation of Russia until the Perestroyka. This study examined the dwellings of Korean Diaspora in Yunhaju through visiting their houses and having an interview. Results of research were as following: 1) Russian traditional houses which Koreans built was followed by Russian style basically and Koreans used the space slightly different way. Korean Diaspora have been adopted Russian life style with keeping their own traditional way of living. 2) Some Korean Diaspora still have been kept traditional heating system 'Ondol' in their houses until now in Yunhaju. Moreover over, it is known that people of Central Asia prefer to set 'Ondol' recently as a very specific and expensive heating system. 3) Korean's food style in Yunhaju is the one mixed with Russian, Korean, and Central Asian foods. This study could be a first step to supply for a basic information for studying of Korean Diaspora in Russia and it is needed to take more deep research in other areas in Russia.

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF