• Title/Summary/Keyword: On-machine Measurement

Search Result 1,030, Processing Time 0.025 seconds

Usability Test of 'Paldokangsan3' a Walking Game for the Elderly (노인용 걷기게임 '팔도강산3'의 사용성 연구)

  • Kim, KyungSik;Lee, YoonJung;Oh, DooNam
    • Journal of Korea Game Society
    • /
    • v.15 no.1
    • /
    • pp.145-154
    • /
    • 2015
  • The objective of this research is to evaluate the usability test of 'Paldokangsan3' which has been developed as a serious game for the elderly to improve their physical and mental health. This game machine has been installed in a silver house for one month that the elderly could play the game as they like in their convenient times. To promote their participations to practice the game, we set 3 contests with gifts for the high scores and collect their data through inspection, questionnaire and interviews by the researchers as well as in-game measurement for the play. Eight people volunteered to join the project. While the result analysis for the usability area of easiness of control, learnability of the game play, memorability and challenge didn't show the statistical confident t-value, most elderly players participated 2~3 times a day for a month even though most of them are suffering mild cognition impairment. They showed good subjective satisfactions in their interviews that we could go on the project further to expand its applications.

System Implementation and Algorithm Development for Classification of the Activity States Using 3 Axial Accelerometer (3축 가속도를 이용한 활동상태 분류 시스템 구현 및 알고리즘 개발)

  • Noh, Yun-Hong;Ye, Soo-Young;Jeong, Do-Un
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • A real time monitoring system from a PC has been developed which can be accessed through transmitted data, which incorporates an established low powered transport system equipped with a single chip combined with wireless sensor network technology from a three-axis acceleration sensor. In order to distinguish between static posture and dynamic posture, the extracted parameter from the rapidly transmitted data needs differentiation of movement and activity structures and status for an accurate measurement. When results interpret a static formation, statistics referring to each respective formation, known as the K-mean algorithm is utilized to carry out a determination of detailed positioning, and when results alter towards dynamic activity, fuzzy algorithm (fuzzy categorizer), which is the relationship between speed and ISVM, is used to categorize activity levels into 4 stages. Also, the ISVM is calculated with the instrumented acceleration speed on the running machine according to various speeds and its relationship with kinetic energy goes through correlation analysis. With the evaluation of the proposed system, the accuracy level stands at 100% at a static formation and also a 96.79% accuracy with kinetic energy and we can easily determine the energy consumption through the relationship between ISVM and kinetic energy.

Efficient Hardware Architecture for Fast Image Similarity Calculation (고속 영상 유사도 분석을 위한 효율적 하드웨어 구조)

  • Kwon, Soon;Lee, Chung-Hee;Lee, Jong-Hun;Moon, Byung-In;Lee, Yong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.6-13
    • /
    • 2011
  • Due to its robustness to illumination change, normalized cross-correlation based similarity measurement is widely used in many machine vision applications. However, its inefficient computation structure is not adequate for real-time embedded vision system. In this paper, we present an efficient hardware architecture based on a normalized cross correlation (NCC) for fast image similarity measure. The proposed architecture simplifies window-sum process of the NCC using the integral-image. Relieving the overhead to constructing integral image, we make it possible to process integral image construction at the same time that pixel sequences are inputted. Also the proposed segmented integral image method can reduce the buffer size for storing integral image data.

Analysis of the Characteristics of the Feed motor Current for the Estimation of the Cutting Force in General Cutting Environment (일반적 상황에서 2차원 절삭력 추정을 위한 이송모터 전류의 거동분석)

  • Jeong, Young-Hun;Yun, Seong-Hyun;Cho, Dong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.93-100
    • /
    • 2002
  • The current from the feed motor of a machine tool contains substantial information about the machining state. There have been many researches that investigated the current as a measure for the cutting farces. However it has been reported that this indirect measurement of the cutting farces from the feed motor current is only feasible in low frequency. In this research, it was presented that the bandwidth of the current monitoring can be expanded to 130 Hz. And the unusual behavior of the current was examined in this bandwidth. The cross-feed directional cutting force influences the machined surface of the workpiece, which makes it necessary to estimate this force to control the roughness of the machined sulfate. The current exists in the stationary feed motor, and it can give the useful information on the quality of the machined surface. But the unpredictable behavior of the current prevents applying the current to prediction of the cutting state. Empirical approach was conducted to resolve the problem. As a result, the current was shown to be related to the accumulation of the accumulation of the infinitesimal rotation of the motor. rotation of the motor. Subsequently the relationship between the current and the cutting force was identified.

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Performance Evaluation and Analysis of the Screw and Die of the Single Screw Extruder Using the CFD (CFD를 이용한 단축압출기 스크류 및 다이스의 성능시험평가 및 해석에 관한 연구)

  • Kim, Jae-Yoel;Chung, Hyo-Hee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.194-200
    • /
    • 2009
  • The extruder type is classified as screw type and non-screw type in terms of the extrusion method. The screw type extruder, which is the most frequently used, is classified as the single screw extruder and the multi-screw extruder. They are classified as vertical type and horizontal type in terms of structure; and those for compounding and for forming in terms of function. The single screw extruder is a universal extruder, most of which is suitable for the extrusion forming of thermoplastic resin. The multi-screw(two-screw, three-screw and four-screw) extruder can increase the extrusion power using the engagement of the screw flank. The single screw extruder does not have a good mixing ratio of the raw material and stable extrusion power, while it has low construction cost and operation cost. In this study, the single screw extruder, which has many weak points compared with the multi-screw extruder, was studied. There have been many studies on the single screw extruder, and they led to its significant development. The existing study method, however, had complex analysis processes and required much time. In this study, the CFD was applied to the performance test and analysis of the extruder, and the optimal design condition of the extrusion power for the screw and die of the single screw extruder was found by comparing the analysis results with the actual performance measurement of the single screw extruder.

Improvement of Measurement Accuracy by Correcting Systematic Error Associated with the X-ray Diffractometer (X-선 회절 장비의 기계적 오차 수정을 통한 분석 정확도 향상)

  • Choi, Dooho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.97-101
    • /
    • 2017
  • X-ray diffractometers are used to characterize material properties, such as the phase, texture, lattice constant and residual stress, based on the diffracted beams obtained from specimens. Quantitative analyses using X-rays are typically conducted by measuring the peak positions of the diffracted beams. However, the long-term use of the diffractomer, like any other machine, results in errors associated with the mechanical parts, which can deteriorate the accuracy of the quantitative analyses. In this study, the process of correcting systematic errors in the $2{\theta}$ range of $30{\sim}90^{\circ}$ is discussed, for which strain-free Si powders from NIST were used as the standard specimens. For the evaluation of the impact of such error correction, we conducted a quantitative analysis of the true lattice constant for tungsten thin films.

COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION (CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구)

  • Jung Gi-Hun;Kim Eun-Kyung;Kim Sang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Observation of Shape after sinter of Dental Co-Cr sinter metal (치과용 Co-Cr sinter metal의 소결 후 변형비교)

  • Song, Joon-Boo;Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.127-133
    • /
    • 2016
  • Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.