• Title/Summary/Keyword: On-line estimation

Search Result 983, Processing Time 0.038 seconds

Analysis of Line Capacity for the Special Structure in Railway (특이구조를 갖는 선로구간의 용량분석에 관한 연구)

  • Kim Dong-Hee;Hong Soon-Heum
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.668-673
    • /
    • 2003
  • Line Capacity is a criteria for transport capacity and is used to evaluate railroad investment alternatives or to decide train frequency when establish transportation plan. There are two methodologies to increase transport capacity of railway. One is to invest railroad equipment or vehicles, and the other is to improve operation efficiency through optimization. Such all efforts are intended to increase transport capacity by improving line capacity. So far, this criteria is calculated statical and experimental numerical formula. But, line capacity has special attribute that changes dynamically according to operational conditions, so there is a need of new line capacity estimation system. In this paper, we present a new estimation method of line capacity based on the probability simulation, and apply to normal railline section and special structured railine section.

  • PDF

ON-LINE ESTIMATION PROCEDURES OF DIGITAL FILTER TYPE FOR REVERBERATION CHARACTERISTICS IN CLOSED ACOUSTIC SYSTEMS BASED ON NOISY OBSERVATION

  • Hiromitsu, Seijiro;Ohta, Mitsuo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.680-685
    • /
    • 1994
  • The acoustic phenomena in the actual sound systems involve a variety of compound problems. In this paper, the well-known Bayes' theorem is first employed and expanded into orthonormal and non-orthonomal series forms matched to the digital processing of lower and higher order statistical informations and the noisy observations. Proposed on-line algorithms of digital filter type are applied to the actual state estimation for a reverberation characteristics in a room under contamination of background noises.

  • PDF

Line Impedance Estimation Based Adaptive Droop Control Method for Parallel Inverters

  • Le, Phuong Minh;Pham, Xuan Hoa Thi;Nguyen, Huy Minh;Hoang, Duc Duy Vo;Nguyen, Tuyen Dinh;Vo, Dieu Ngoc
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.234-250
    • /
    • 2018
  • This paper presents a new load sharing control for use between paralleled three-phase inverters in an islanded microgrid based on the online line impedance estimation by the use of a Kalman filter. In this study, the mismatch of power sharing when the line impedance changes due to temperature, frequency, significant differences in line parameters and the requirements of the Plug-and-Play mode for inverters connected to a microgrid has been solved. In addition, this paper also presents a new droop control method working with the line impedance that is different from the traditional droop algorithm when the line impedance is assumed to be pure resistance or pure inductance. In this paper, the line impedance estimation for parallel inverters uses the minimum square method combined with a Kalman filter. In addition, the secondary control loops are designed to restore the voltage amplitude and frequency of a microgrid by using a combined nominal value SOGI-PLL with a generalized integral block and phase lock loop to monitor the exact voltage magnitude and frequency phase at the PCC. A control model has been simulated in Matlab/Simulink with three voltage source inverters connected in parallel for different ratios of power sharing. The simulation results demonstrate the accuracy of the proposed control method.

Resonant Frequency Estimation of Reradiation Interference at MF from Power Transmission Lines Based on Generalized Resonance Theory

  • Bo, Tang;Bin, Chen;Zhibin, Zhao;Zheng, Xiao;Shuang, Wang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1144-1153
    • /
    • 2015
  • The resonant mechanism of reradiation interference (RRI) over 1.7MHz from power transmission lines cannot be obtained from IEEE standards, which are based on researches of field intensity. Hence, the resonance is ignored in National Standards of protecting distance between UHV power lines and radio stations in China, which would result in an excessive redundancy of protecting distance. Therefore, based on the generalized resonance theory, we proposed the idea of applying model-based parameter estimation (MBPE) to estimate the generalized resonance frequency of electrically large scattering objects. We also deduced equation expressions of the generalized resonance frequency and its quality factor Q in a lossy open electromagnetic system, i.e. an antenna-transmission line system in this paper. Taking the frequency band studied by IEEE and the frequency band over 1.7 MHz as object, we established three models of the RRI from transmission lines, namely the simplified line model, the tower line model considering cross arms and the line-surface mixed model. With the models, we calculated the scattering field of sampling points with equal intervals using method of moments, and then inferred expressions of Padé rational function. After calculating the zero-pole points of the Padé rational function, we eventually got the estimation of the RRI’s generalized resonant frequency. Our case studies indicate that the proposed estimation method is effective for predicting the generalized resonant frequency of RRI in medium frequency (MF, 0.3~3 MHz) band over 1.7 MHz, which expands the frequency band studied by IEEE.

Application of Computer-coupled Mass Spectrometer for Continuous On-line Monitoring of Cell Growth and Growth Rate (세포증식과 증식속도의 On-line Monitoring을 위한 Computer- coupled Mass Spectrometer의 응용)

  • 남수완;최춘순;김정회
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.241-246
    • /
    • 1989
  • Continuous on-line monitoring of cell concentration and growth rate in aerobic batch fermentation process was carried out by analyzing the exhaust gas composition of tormentor with a quadrupole mass spectrometer. From the mass spectrometric analyses of major gaseous components, i.e. $N_2$, $O_2$, $CO_2$ and $H_2O$, and the material balance equations for oxygen and carbon dioxide, oxygen uptake rate (OUR) rind carbon dioxide evolution rate (CER) were instantaneously calculated using a computer (16-bit IBM PC-AT) interfaced to a quadrupole mass spectrometer. The calculated OUR and CER data were used for the estimation of cell concentration and growth rate of Candida utilis during batch culture. It was found that the cell concentration could be satisfactorily estimated from the data of OUR arid CER during the culture and this method could be successfully und for the continuous monitoring of cell growth and growth rate.

  • PDF

Voltage Estimation Method for Distribution Line with Irregularly Dispersed Load (부하가 불규칙하게 분포된 배전선로의 전압추정 방법)

  • Park, Sanghyeon;Lim, Seongil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.491-497
    • /
    • 2018
  • Most of the applications for distribution system operation highly rely on the voltage and current managements from the field devices. Voltage from the remote controlled switch contains unacceptably large measurement error due to the nonlinear characteristics of the bushing potential transformer. This paper proposes a new voltage magnitude estimation method by calculating voltage drop using current measurement, line impedance and loads deployment data. Contract demand power and pole transformer capacity managed by NDIS are used as a key element to improve accuracy of the proposed method. Various case studies using Matlab simulation have been performed to verify feasibility of the propose voltage estimation method.

A Power-line Frequency Monitoring Intelligent Electronic Device(IED) Platform (전력선 주파수 모니터링을 위한 Intelligent Electronic Device(IED) 플랫폼)

  • Jeon, Hyeon-Jin;Yi, Don-Jin;Jeon, Jun-Gil;Chang, Tae-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.1047-1049
    • /
    • 2009
  • This paper presents an intelligent electronic device(IED) platform which is based on a new frequency estimation algorithm. The IED platform features not only the accurate estimation of frequency but also the fast network-based transmisstion of fault data and waveforms. The simulation results show that the proposed frequency estimation algorithm improves convergence speed, and has lower frequency estimation error compared with those of conventional algorithms. The network-based IED is designed to ensure transmission latency being less than 1.0% of sampling interval.

Enhanced Fault Location Algorithm for Short Faults of Transmission Line (1회선 송전선로 단락사고의 개선된 고장점 표정기법)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

A Fast 3D Depth Estimation Algorithm Using On-line Stereo Matching of Intensity Functionals (영상휘도 함수의 온 라인 스테레오 매칭을 이용한 고속 3차원 거리 추정 알고리즘)

  • Kwon, H.Y.;Bien, Z.;Suh, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.484-487
    • /
    • 1989
  • A fast stereo algorithm for 3D depth estimation is presented. We propose an on-line stereo matching technique, by which the flows of stereo image signals are dynamically controlled to satisfy the matching condition of intensity functionals. The disparity is rapidly estimated from the control of. the signal flows and 3D depth is determined from the disparity.

  • PDF

RC Circuit Parameter Estimation for DC Electric Traction Substation Using Linear Artificial Neural Network Scheme (선형인공신경망을 이용한 직류 전철변전소의 RC 회로정수 추정)

  • Bae, Chang Han;Kim, Young Guk;Park, Chan Kyoung;Kim, Yong Ki;Han, Moon Seob
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.314-323
    • /
    • 2016
  • Overhead line voltage of DC railway traction substations has rising or falling characteristics depending on the acceleration and regenerative braking of the subway train loads. The suppression of this irregular fluctuation of the line voltage gives rise to improved energy efficiency of both the railway substation and the trains. This paper presents parameter estimation schemes using the RC circuit model for an overhead line voltage at a 1500V DC electric railway traction substation. A linear artificial neural network with a back-propagation learning algorithm was trained using the measurement data for an overhead line voltage and four feeder currents. The least square estimation method was configured to implement batch processing of these measurement data. These estimation results have been presented and performance analysis has been achieved through raw data simulation.