  • We here investigate an existence and uniqueness of the nontrivial, nonnegative solution of a nonlinear ordinary differential equation: $$[\mid(w^m)]'\mid^{p-2}(w^m)']'\;+\;{\beta}rw'\;+\;{\alpha}w\;+\;(w^q)'\;=\;0$$ satisfying a specific decay rate: $lim_{r\rightarrow\infty}\;r^{\alpha/\beta}w(r)$ = 0 with $\alpha$ := (p - 1)/[pd-(m+1)(p-1)] and $\beta$:= [q-m(p-1)]/[pd-(m+1)(p-1)]. Here m(p-1) > 1 and m(p - 1) < q < (m+1)(p-1). Such a solution arises naturally when we study a very singular solution for a doubly degenerate equation with nonlinear convection: $$u_t\;=\;[\mid(u^m)_x\mid^{p-2}(u^m)_x]_x\;+\;(u^q)x$$ defined on the half line.

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings (수력발전기 고정자 권선의 운전중 부분방전 특성)

  • Kim, Byong-Han;Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

Prefilter Type Velocity Compensating Robot Controller Design using Modified Chaotic Neural Networks (Prefilter 형태의 카오틱 신경망 속도보상기를 이용한 로봇 제어기 설계)

  • Hong, Su-Dong;Choi, Un-Ha;Kim, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.4
    • /
    • pp.184-191
    • /
    • 2001
  • This paper proposes a prefilter type velocity compensating control system using modified chaotic neural networks for the trajectory control of robotic manipulator. Since the structure of modified chaotic neural networks(MCNN) and neurons have highly nonlinear dynamic characteristics, MCNN can show the robust characteristics for controlling highly nonlinear dynamics like robotic manipulators. For its application, the trajectory controller of the three-axis robot manipulator is designed by MCNN. The MCNN controller acts as the compensator of the PD controller. Simulation results show that learning error decrease drastically via on-line learning and the performance is excellent. The MCNN controller showed much better control performance and shorter calculation time compared to the RNN controller, Another advantage of the proposed controller could by attached to conventional robot controller without hardware changes.

  • PDF

Analysis of On-Line Partial Discharge Trend in High Voltage Motors (고압전동기 운전중 부분방전 추이 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Chung-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1472-1473
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) measurements were peformed with turbine generator analyzer(TGA) in two high voltage motors(rated 6.6 kV). These high voltage motors were installed with 80 pF capacitive couplers at the terminal box. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude (Qm). The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in stator windings of high voltage motors.

  • PDF

Drone-based Power-line Tracking System (드론 기반의 전력선 추적 제어 시스템)

  • Jeong, Jongmin;Kim, Jaeseung;Yoon, Tae Sung;Park, Jin Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.773-781
    • /
    • 2018
  • In recent years, a study of power-line inspection using an unmanned aerial vehicle (UAV) has been actively conducted. However, relevant studies have been conducting power-line inspection with an UAV operated by manual control, and they have developed just power-line detection algorithm on aerial images. To overcome limitations of existing research, we propose a drone-based power-line tracking system in this paper. The main contributions of this paper are to operate developed system under configured environment and to develop a power-line detection algorithm in real-time. Developed system is composed of the power-line detection and the image-based tracking control. To detect a power-line in real-time, a region of interest (ROI) image is extracted. Furthermore, clustering algorithm is used in order to discriminate the power-line from background. Finally, the power-line is detected by using the Hough transform, and a center position and a tilt angle are estimated by using the Kalman filter to control a drone smoothly. We design a position controller and an attitude controller for image-based tracking control, and both controllers are designed based on the proportional-derivative (PD) control method. The interaction between the position controller and the attitude controller makes the drone track the power-line. Several experiments were carried out in environments where conditions are similar to actual environments, which demonstrates the superiority of the developed system.

Sensory Feedback for High Dissymmetric Master-Slave Dexterity

  • Cotsaftis, Michel;Keskinen, Erno
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.38-42
    • /
    • 2002
  • Conditions are discussed for operating a dissymmetric human master-small (or micro) slave system in best (large position gain-small velocity gain) conditions allowing higher operator dexterity when real effects (joint compliance, link flexion delay and transmission distortion) are taken into account. It is shown that position PD feedback law advantage for ideal case no longer holds, and that more complicated feedback law depending on real effects has to be implemented with adapted transmission line. Drawback is slowdown of master slave interaction, suggesting to use more advanced predictive methods for the master and more intelligent control law for the slave.

On-line Measurement of Partial Discharge (활선상의 부분방전 측정 방법)

  • Paek, Kwang-Hyeon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1936-1938
    • /
    • 2004
  • In this paper, we discussed measurement method of PD (Partial Discharge) of 22.9[kV] cable. Cable rail track laying portable detector that can detect partial discharge of cable connection ashes by on-line done spot way to detect Lemke equipment and high broadcasting CT sensor that use antenna sensor using ICM mounting was explained. Because measurement corona signal is very big, analysis of partial discharge is difficult state, we used connector. It could be attenuated by 2 times. We found out that corona signal which generated on B phase is flowed on A phase and C phase. It could measure that partial discharge of A phase happens actually. We could confirm that partial discharge of about 250 ${\sim}$ 300 [pC] on A phase is dangerous.

  • PDF

Recent Progress in Immunotherapy for Gastric Cancer

  • Jeesun Yoon;Tae-Yong Kim;Do-Youn Oh
    • Journal of Gastric Cancer
    • /
    • v.23 no.1
    • /
    • pp.207-223
    • /
    • 2023
  • Gastric cancer (GC) is the fourth leading cause of cancer-related deaths worldwide. Under the standard of care, patients with advanced GC (AGC) have a median survival time of approximately 12-15 months. With the emergence of immunotherapy as a key therapeutic strategy in medical oncology, relevant changes are expected in the systemic treatment of GC. In the phase III ATTRACTION-2 trial, nivolumab, a monoclonal anti-programmed cell death 1 (PD-1) antibody, as a third- or later-line treatment improved overall survival (OS) compared with placebo in patients with AGC. Furthermore, nivolumab in combination with 5-fluorouracil and platinum as a first-line treatment improved OS in patients with human epidermal growth factor receptor-2 (HER2)-negative AGC in the global phase III CheckMate-649 study. Another anti-PD-1 antibody, pembrolizumab, in combination with trastuzumab and cytotoxic chemotherapy as a first-line treatment, significantly improved the overall response rate in patients with HER2-positive AGC. Therefore, immune checkpoint inhibitors (ICIs) are essential components of the current treatment of GC. Subsequent treatments after ICI combination therapy, such as ICI rechallenge or combination therapy with agents having other modes of action, are being actively investigated to date. On the basis of the success of immunotherapy in the treatment of AGC, various clinical trials are underway to apply this therapeutic strategy in the perioperative and postoperative settings for patients with early GC. This review describes recent progress in immunotherapy and potential immunotherapy biomarkers for GC.

A Study on On-Line Monitoring & Diagnosis of Temperature, Vibration and Insulation Condition (고압 회전기의 운전중 온도, 진동 및 절연상태 종합 감시진단 연구)

  • Hwang, Don-Ha;Sim, Woo-Young;Kang, Dong-Sik;Kim, Yong-Joo;Song, Sang-Ock;Lee, Jin-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1894-1896
    • /
    • 2003
  • In this paper, a novel monitoring system, data acquisition & diagnosis unit (DADU), for high-voltage rotating machines is proposed. This system monitors the insulation condition, current, voltage, vibration, and temperature of the stator winding by on-line measurements of partial discharge (PD), flux, etc. This helps more efficient operation and maintenance of the rotating machines.

  • PDF