• Title/Summary/Keyword: On-axis

Search Result 6,809, Processing Time 0.036 seconds

The Echocardiographic Assessment and clinical Application of Cardiac Disease in Korean Jin-do dog (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 I. 심장초음파 측정치)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.178-186
    • /
    • 2000
  • Echocardiography was performed on 29 normal Korea Jin-do dogs(21 adults and 8 prematures) and the images were taken from chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view, respectively. The following cardiac parameters, in systole and diastole, were measured on the echoocardographic images: aortic dimension(AO), left atrial dimension(LA), left ventricular internal dimention at end-diastole (LVIDd), left ventricular internal dimention at end-systole(LVIDs), interventricular septal wall thickness at end-diastole(IVSd), interventricular septal wall thickness at end-systole(IVSs), left ventricular wall at end-diastole(LVWd), left ventricular wall at end-systole(LVWs). The cardiac parameters were not significantly different between sex and among imaging planes. The size of cardiac parameters increaed as regression lines according to body weights. These results suggest that the chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view can be utilized for the left cardiac examination, and these cardiac parameters can be used to basic dat for diagnosing the cardiac diseases in Korea Jin-do dog.

  • PDF

Engine Mounting System Optimization for Improve NVH (NVH 향상을 위한 엔진 설치 시스템 최적화)

  • Kim, Jang-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4665-4671
    • /
    • 2013
  • Engine mounting system is the most responsible system for NVH performance of vehicle. The vibration at idle shake, road shake, Key ON/OFF, gear shift tuned by the engine mount position and stiffness. Previously described Engine mounting system theory investigated and summarized in this paper. Decoupling of the Power train rigid mode and Reducing the angle between Torque-Roll-Axis and Elastic-roll-Axis is starting point of optimization. Multi-optimization analysis was performed because of variety simulation case and FE-model. Eventually, Find the best mount location and the stiffness has improved the performance of the vehicle NVH.

A Study on Driving Range of Cylinder Block to Eccentricity Ratio of Disk in Bent axis Type Oil Hydraulic Piston Pump (사축식 유압 피스톤 펌프의 디스크 편심률에 따른 실린더블록 구동영역에 대한 연구)

  • Jung, J.Y.;Baek, I.H.;Cho, I.S.;Song, K.K.;Oh, S.H.;Jeong, Y.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • To improve the performance of the bent axis type axial piston pump driven by the tapered piston, it is necessary to know the driving characteristics and mechanism of the tapered piston and the cylinder block. Since each piston not only rotates on its axis and reciprocates in the cylinder bore, but also revolves around the axis of the driving shaft, it is difficult to analyze the driving mechanism theoretically. The theoretical mechanism far the bent axis type axial piston pump is studied by using the geometrical method. The driving range of the tapered piston is determined by theoretical equations. The results show that the cylinder block is driven by one tapered piston in a limited range and the core parameters such as driving factor of the piston and the ahead delay angle influenced performance of the bent axis type axial piston pump.

  • PDF

Development of High-Precision Measuring Device for Six-axis Force/Moment Sensor (로봇용 6축 힘/모멘트 센서를 위한 고성능측정기 개발)

  • Shin, Hyi-Jun;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.46-53
    • /
    • 2007
  • This paper describes the development of a high-precision measuring device with DSP (digital signal processor) for the accurate measurement of the 6-axis force/moment sensor mounted to a humanoid robot's ankle. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, and Fz and moments Mx, My, and Mz to itself, and control the foot using the measured them. The applied forces and moments should be measured from two 6-axis force/moment sensors mounted to the feet, and the sensor is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body (single block). In order to acquire output values from twelve sensors (two 6-axis force/moment sensor) accurately, the measuring device should get the function of high speed, and should be small in size. The commercialized measuring devices have the function of high speed, unfortunately, they are large in size and heavy in weight. In this paper, the high-precision measuring device for acquiring the output values from two 6-axis force/moment sensors was developed. It is composed of a DSP (150 MHz), a RAM (random access memory), amplifiers, capacities, resisters and so on. And the characteristic test was carried out.

Study on the Total Design of a Conical Involute Gear (코니칼 인볼류트 기어의 Total 설계에 관한 연구)

  • Kim, Jun-Seong;Lee, Do-Young;Kang, Jai-Hwa;Xu, Zhe-Zhu;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.100-107
    • /
    • 2014
  • Currently, there are many power transmission devices, including gears, friction wheels, chains, and belts. Because the power transmission of gears is most certainin these devices, gears are widely used in different power transmission fields and environments. In accordance with the gear shape, gears can be classified as cylindrical gears and conical gears. A cylindrical gear, which provides a means of power transmission under parallel axis and skewed axis conditions, contains a spur gear, a helical gear and a worm gear. A conical gear, which can be used on a skewed axis as well as parallel and crossed axes, includes a bevel gear(e.g., straight bevel, spiral bevel, hypoid gear) and a conical involute gear(or a bevel oid gear). In this paper, a conical involute gear which utilizes the fabrication method of other involute gears such as spur and helical gears using a CNC hobbing machine is discussed.

Effects of Higher-Order Laue Zone Reflections on HRTEM Images for illumination along an off-Bone Axis of a Crystal (비 결정 축(off-zone axis)으로 입사된 빔에 대한 고 분해 투과전자현미경 이미지에서 HOLZ 반사 빔의 효과)

  • Kim, Hwang-Su
    • Applied Microscopy
    • /
    • v.37 no.4
    • /
    • pp.259-269
    • /
    • 2007
  • In this paper we explored a possibility of observation for effects of higher-order Laue zone(HOLZ) reflections on high resolution transmission electron microscope(HRTEM) images for illumination along an off-zone axis of a crystal. The analysis of the observation could give useful three dimensional crystal structure information. For the image simulation the Howie-Whelan equation was used with modification of including HOLZ reflections. This study clearly indicates that HRTEM images for a very thin crystal tilted by a few degrees from a zone axis show the effects of HOLZ reflections and contain some information of atomic arrangements along the zone axis.

IL-2-enhanced NK Cell Cytotoxicity is Regulated by Adiponectin from Hypothalamo-pituitary-adrenal Axis (Adiponectin에 의한 IL-2 증가 자연살해세포 독성의 조절)

  • Kim, Keun-Young;Yang, Young
    • IMMUNE NETWORK
    • /
    • v.6 no.1
    • /
    • pp.6-12
    • /
    • 2006
  • Background: The Hypothalamo-Pituitary-Adrenal (HPA) axis is an important regulator for the body's stress response. As a primary stress responsive system, HPA-axis secretes various neurotransmitters, hormones, and cytokines, which regulates the immune system. Natural killer (NK) cell which is plays an important role in the innate immune response, is specially decreased their numbers and loose cytolytic activity in response to stress. However, the effect of HPA-axis secreted proteins on NK cell activity has not been defined. Herein, we studied the effect of adrenal secreted adiponectin on NK cell cytotoxicity. Adiponectin which is well-known metabolic control protein, plays important roles in various diseases, including hypertension, cardiovascular diseases, inflammatory disorders, and cancer. Methods: Signal sequence trap was used to find stress novel secretory protein from HP A-axis. Selected adiponectin was treated mouse mature primary NK cells and then examined the effect of adiponectin to NK cell cytotoxicity and cytokine expression level. Results: We found that adiponectin which is secreted from adrenal gland, suppress IL-2 induced NK cell cytotoxicity. And also investigated cytolytic cytokines are suppressed by adiponectin. Conclusion: These data suggest that adiponectin inhibites NK cell cytotoxicity via suppression of cytotoxicity related target gene.

Evaluation of Erythrocyte Morphometric Indices in Juvenile Red Spotted Grouper, Epinephelus akaara under Elevated Water Temperature

  • Rahman, Md Mofizur;Baek, Hea Ja
    • Development and Reproduction
    • /
    • v.23 no.4
    • /
    • pp.345-353
    • /
    • 2019
  • Higher thermal exposure can influence the blood cell morphology and count. Hence, based on the previous results (Rahman et al., 2019), the present study evaluated the morphometric indices of erythrocytes and their nucleus under different water temperatures (25℃, 28℃, 31℃, and 34℃) to investigate their use as an indicator of thermal stress in red spotted grouper, Epinephelus akaara. 180 healthy specimens of E. akaara were exposed to four temperature conditions (25℃ as control, 28℃, 31℃, and 34℃) for 42 days, following 2 weeks of acclimation at 25℃. Erythrocyte major axis (EL), erythrocyte minor axis (EW), nucleus major axis (NL), and nucleus minor axis (NW) were examined from the blood smears on each sampling day (i.e., 2, 7, and 42 days of thermal exposure). EL and NL were significantly decreased, whereas EW and NW were increased at higher water temperature (31℃ and 34℃). The major-minor axis proportions of erythrocytes and their nucleus (EL/EW; NL/NW) were decreased with increasing water temperature (31℃ and 34℃). The strong relationships were observed among the morphometric indices of erythrocytes and their nucleus, especially in EL vs. NL and EW vs. NW. This study reveals that elevated water temperature (31℃ and 34℃) can influence the major and minor axis morphometry of erythrocytes and their nucleus in red spotted grouper. These indices may be used as stress indicators to monitor the health status of E. akaara and probably for other fish species.

A Study on the Test Workpiece for Accuracy Evaluation of 5-Axis Machine Tool (5축 공작기계 정밀도 평가를 위한 표준 공작물에 관한 연구)

  • Youn, Jae-Woong;Kim, Ki-Hwan;Park, Jong Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • Recently, a demand for precision 5-axis machine tools is significantly increasing, and the maintenance of machine tool accuracy becomes more important. it is very difficult to evaluate to accuracy of 5-axis M/C in the production site since it needs expensive measuring equipment and skilled engineer. On the other hand, evaluation items of 5-axis M/C are not systematically organized in the existing KS and ISO standards. In this study, the evaluation items for 5-axis M/C were derived systematically and a test workpiece was developed to evaluate the machine tool accuracy more easily. The error sources of machine tool can be estimated by machining and measuring of the test workpiece. The correlation between the machine tool accuracy and the accuracy of machined test workpiece was analyzed. As a result, the accuracy of machined test workpiece represented the accuracy of machine tool and the error sources very effectively.

Real-Time Correction of Movement Errors of Machine Axis by Twyman-Green Interferometry (광위상 간섭을 이용한 이송축의 운동오차 실시간 보상)

  • 이형석;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3115-3123
    • /
    • 1993
  • This paper presents a real-time correction method of the movemont errors of a translatory precision machine axis. This method is a null-balances technique in which two plane mirrors are used to generate an interferometric fringe pattern utilizing the optical principles of TwymanGreen interferometry. One mirror is fixed on a reference frame, while the other is placed on the machine axis being supported by three piezoelectric actuators. From the fringe pattern, one translatory and two rotational error components of the machine axis are simultaneously detected by using CCD camera vision and image processing techniques. These errors are then independently suppressed by activating the peizoelectric actuators by real-time feedback control while the machine axis is moving. Experimental results demonstrate that a machine axis can be controlled with movement errors less than 10 nm in vertical straightness, 0.1 arcsec in pitch, and 0.06 arcsec in roll for 50mm travel by adopting the real-time correction method.