• Title/Summary/Keyword: Old facility

Search Result 301, Processing Time 0.025 seconds

A Study on the Unification of The Grounding System of SeoulMetro due to Ageing (서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준)

  • Min Byung-Hoon;Kim Gyunl-Sig;Chung Young-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.394-400
    • /
    • 2006
  • Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.

An Expert System for Protection Coordiantion in 22.9KV Distribution System Design (22.9KV 배전설게 보호협조을 위한 전문가 시스템)

  • 김호용;고윤석;손수국;남기영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.119-132
    • /
    • 1990
  • To design protection coordination for an electric power distribution system, an expert system is developed, using both the veteran expert's heuristics and the guide book for the distribution facility operation considering feeder configuration, service route, load characteristics fault current and load current. The expert system developed in this papaer determines the type of protective device(clearing current and sequence). The location and rating change of protective device in the old feeder is realized by using old database. Current(T-C) curves of various kinds of protective devices are stored in Knowledge Base (KB). The expert system is developed on a 32 bit personal computer using PROLOG, AutoCAD,dBASEIIIPLUS and FORTRAN. To compute the fault current and loadflow, FORTRAN is used.

  • PDF

A Study on the Improvement of the Silver-Zone Selecting Method (노인보호구역 지정방법 개선에 관한 연구)

  • Kim, Jang-Wook;Hong, Joo-Hee;Kim, Jeong-Hyun;Lee, Soo-Beom
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.1
    • /
    • pp.78-88
    • /
    • 2009
  • As the silver population rapidly increased, it became more urgent to establish a scheme of the traffic safety for the old. As part of the scheme, a polity to apply 'designation of the silver zone' was legislated into law. However, the standard quoting 'the silver zone should be within 300m - radius of the relevant facility' was considered homogeneous and even limited to apply its original objective. This study was to introduce a new standard to select the silver zone reflecting the actual scale. Consequently, I hope that this study would be useful reference for further development and the approach in the research could be legislated into law for more efficient designation and operation of the silver zone.

A Basic Study on the Safety Management and Quantification of Vulnerability Factors in Small-size Old Buildings (소규모 노후 건축물 안전관리 및 취약성 요소 정량화 기본연구)

  • Goh, Wolsan;Oh, Gyuho;Ahn, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.249-250
    • /
    • 2023
  • The vulnerability factor analysis and risk quantification model for aging buildings presented in this study can be utilized by governmental agencies such as the Facility Safety Foundation, the Ministry of Land, Infrastructure and Transport, and various local governments. Policymakers can use this to supplement inadequacies in existing checklists, and it is expected that they can proactively prevent risks by evaluating dangers based on specific aging characteristics of buildings.

  • PDF

Clinical characteristics of heat stroke in bath facilities, and analysis of predictive factors of multiple major complications (목욕시설에서 발생한 열사병의 임상양상 및 열사병의 다발성 주요 합병증에 관한 예측인자 분석)

  • Park, Seok-Jin;Hyun, Sung-Youl;Lim, Yong-Su;Cho, Jin-Seong;Min, Kyoung-Jeen;Yang, Hyuk-Jun
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.500-508
    • /
    • 2018
  • Objective: The aim of this study was to evaluate the clinical characteristics of heat stroke in a bath facility and investigate predictive factors of multiple major complications in heat stroke patients. Methods: This was a retrospective study on heat stroke patients who visited an urban emergency center from January 2010 to March 2018. We compared clinical characteristics, complication, and outcomes of heat stroke patients in bath and non-bath facilities. Multivariate logistic regression analysis were performed to identify independent predictors of multiple major complications in heat stroke patients. Results: A total of 67 heat stroke patients with heat stroke were enrolled, of which 42 (62.6%) were in a bath facility and 25 (37.3%) were in a non-bath facility. Patients with heat stroke in the bath facility were characterized by old age, past medical history of hypertension and diabetes mellitus, and high incidence of hypotension compared with those in the non-bath facility but also low incidence of acute renal failure, seizure, and multiple major complications. In the multivariate analysis, predictive factors of multiple major complications in heat stroke patients were non-bath facility (odds ratio [OR], 5.4; 95% confidence interval [CI], 1.2-29.9), Glasgow Coma Scale (GCS)${\leq}8$ (OR, 8.2; 95% CI, 1.3-49.4), and mean arterial pressure (MAP), body temperature above $40.5^{\circ}C$ (OR, 8.1; 95% CI, 1.1-58.8) <60 mmHg (OR, 14.8; 95% CI, 1.8-122.9). Conclusion: Heat stroke in the bath facility resulted in less major complications, and high body temperature, GCS ${\leq}8$, and MAP <60 mmHg were independent predictive factors of multiple major complications in heat stroke patients.

A Study the Recycling method and Safety of Ascon (아스콘 안전도와 효율적인 재활용 방안에 관한 연구)

  • 허성관;권택진
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.4
    • /
    • pp.67-72
    • /
    • 2000
  • A special double drier structure at a plant level is developed to recycle old ascon as well as an economic mixture rate of old with new is analyzed under safety consideration in this thesis. Based upon the experimentations performed throughout this research, 35% of old ascon mixture is found to be the best for flow test, stability, air void, density, and moisture susceptibility. It is also found that mixture does not meet the requirement in indirect tensile test, However, it is concluded that it is not critical at all since the experimental results present that the difference is too small to give any meaningful indication. A good return for the investment of this facility can be obtained if the mixture rate guideline suggested in this research is kept.

  • PDF

A Study the Recucling Method and Safety of Ascon (아스콘 안전도와 효율적인 재활용 방안에 관한 연구)

  • 허성관;권택진
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.11a
    • /
    • pp.471-482
    • /
    • 2000
  • A special double drier structure at a plant level is developed to recycle old ascon as well as an economic mixture rate of old with new is analyzed under safety consideration in this thesis. Based upon the experimentations performed throughout this research, 35% of old ascon mixture is found to be the best for flow test, stability, air void, density, and moisture susceptibility. It is also found that the mixture does not meet the requirement in indirect tensile test, However, it is concluded that it is not critical at all since the experimental results present that the difference is too small to give any meaningful indication. A good return for the investment of this facility can be obtained if the mixture rate guideline suggested in this research is kept.

  • PDF

A Study on the Design Guide of Fee Charging Residential Facility for the Elderly reflected in Color Perception Characteristic (노인의 색지각적 특성을 고려한 유료 노인주거 실내공간의 설계지침에 관한 연구)

  • Song, Choon-Eui;Kim, Moon-Duck
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.247-256
    • /
    • 2007
  • Aging brings color-weakness to the eye due to yellowed eye sight. The 87% of information required for human behavioral decisions are visually perceived. Therefore, the color-weakness will affect behavior in many ways. Most of previous research regarding color planning for the aged focuses on discovering their preferred colors and reflecting the colors on facility color planning. But such research failed to identify the confused range of color cognitions due to the color weakness of the aged. The purpose of this study is to propose a design guide for fee-charging residential facilities for the elderly, reflecting upon color perception characteristics. An experimental simulation on aged vision using the UV filter and Y-2 filter, YA-3 filter alternating for general eyesight, 70 year-old and late 80 year-old was conducted. The results of this study are as follow : color perception is changed by crystalline lens aging process and yellowed eye sight. The recognition arrangement of colors was preferred to contrast harmony rather than similarity harmony and the dominant color is a warm color rather than a cool color.

  • PDF

A Qualitative Analysis on Familial Caregivers' Burden in Utilizing a Nursing Home for the Elderly (유료 노인전문요양원 이용 경험에 관한 질적 연구)

  • 김완희;박종연;이지전;강임옥
    • Health Policy and Management
    • /
    • v.13 no.1
    • /
    • pp.1-22
    • /
    • 2003
  • The principal objective of this study was to analyze and conceptualize the socio-psychological burden in utilizing a nursing home for elderly. The subjects were five elderly from a private nursing home located in Seoul and their familial caregivers. An old male and three females were currently staying at the facility, and a female had been discharged already from there. Data were collected through depth interviews, observations and review of records at the facility For analysis, the data were classified by similar contents among significant expressions and factors in common. The subjects' motives to consider admission to the nursing home might be attributed to familial caregivers' burden, a shortage of support, environmental improvement and feeling of helplessness for the case elderly. The concept of burden is including family members' being badly off in living, their weariness, complications among family members, feeling psychological uneasiness, and hospital expenses. The identified image of nursing homes for the elderly in Korea was generally negative at the point of high cost, unreasonable requisites and limitations for admission to the facilities, inferior situations, and especially in that there were few long-term care facilities within the community boundary. From their experience of nursing homes, the interviewees have felt the sentiments of sorry for their old parents, with the thought of being an undutiful, bitterness, and empathy. Additionally, they expressed a sense of anxiety of relative deprivation against the fact that there were no long-term care facilities available for the middle class. On the basis of these, multi-dimensional needs could be identified for the elderly with chronic illnesses.

A Study on the Direction of Residential Environment Improvement through the Residents Survey in Long-term Public Rental Housing (장기공공임대주택 주민의식조사를 통한 주거환경개선방향 설정연구)

  • Lee, Ji-Eun;Yoon, Young-Ho;Kim, Yu-Jeong
    • Land and Housing Review
    • /
    • v.4 no.1
    • /
    • pp.65-75
    • /
    • 2013
  • The residential environment of old and deteriorated public rental housing has been improved for preventing house deterioration through the facility improvement projects during the recent three years. The purpose of this study is to check the effect of applied facility improvement projects through a survey to residents on the significance degree of improving the residential environment and the satisfaction degree of current residential environment. Moreover, this study aims to draw out the direction of the residential environment improvement. At first, for this purpose, a survey to the residents of old and deteriorated public rental housing in the country was conducted. In addition, the mean value analysis on the satisfaction degree and significance degree was done, and the factor analysis was conducted for the distinction between types of items. As a result, 29 items of residential public space for residential environment improvement were divided into six factors and 28 items for generation of each units were divided into four factors. The mean value of the satisfaction degree and significance degree was compared. In conclusion, the design direction of environment improvement projects in the future was suggested with the result of the survey.