• Title/Summary/Keyword: Oil drain system

Search Result 13, Processing Time 0.019 seconds

A Study on the Engine Friction & Lubrication Characteristics related with Oil Aeration (오일 Aeration에 따른 엔진의 마찰 및 윤활 특성에 대한 연구)

  • 김영직;이창희;윤정의
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.184-189
    • /
    • 1999
  • This Paper presents the friction and lubrication charateristic related with oil aeration. It is well known that oil aeration occurs severe problem on lubrication system, in particular, in the engine bearings and hydraulic lash adjuster. In this study, engine tests were carried out in motoring conditions. In order to investigate oil aeration characteristics, we measured oil aeration with respect to oil temperature, oil viscosity, modified oil drain system. From the results, we concluded that aeration can be reduced by improving oil drain system and FMEP can be reduced by minimising of aeration.

  • PDF

A Study on the Correlation of Oil Drain and Engine Tilting Angle (오일 드레인과 엔진경사각도간의 상관관계)

  • Kim, Dae-Yeol;Park, Pyong-Wan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.51-57
    • /
    • 2011
  • Parametric studies based on analysis of lubrication system of a four cylinder gasoline engine are illustrated system in this paper. In development process of engine lubrication system, parts of failure cases are related with oil pull over and oil churning phenomenon. The crankcase & head system pressure by oil churning phenomenon are gradual increased. It cause oil pull over phenomenon at engine breather line and oil over-consumption. In order to improve oil reduction and oil pull over phenomenon are also considered in the developing state. For this study, the characteristics of engine lubrication system are measured at various tilting angle and drain hole sizes. In addition, the oil flow & oil quantity are tested by blow by meter and catch jar. Results are presented to stabilize the oil supply system at sever driving condition. The data from present study are available for the engine lubrication system.

Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant (뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰)

  • Lee, Jae Keun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF

An Analyse for Solidified Accident of Nile Blend Crude Oil (히팅카고 응고사고 분석 - 나일브렌드를 중심으로 -)

  • 김영모;이옥용
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.8 no.2
    • /
    • pp.79-86
    • /
    • 2002
  • A heating cargo is solidified by several reasons during carriage. This study is to analyse a cargo accident which 811,202 US barrels of Nile Blend crude oil reamined solid In the tanks after discharge. There are some possibilities that low temperature of Beading cargo below cloud point and wax appearance temperature at loading time, heating interruption during voyage or discharging, and prohibition of crude oil washing during discharging might influence the cargo solidified. But we concluded that the defect of heating system would most affect the heating cargo solidified locally, and which blocked drain hole of bottom transverse and web frame and they obstruct flow of heating cargo in the tanks.

  • PDF

An Analyse for Solidified Accident of Nile Blend Crude Oil (히팅카고 응고사고 분석 - 나일브렌드를 중심으로 -)

  • 김영모;이옥용
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2002.10a
    • /
    • pp.59-70
    • /
    • 2002
  • A heating cargo is solidified by several reasons during carnage. This study is to analyse a cargo accident which 811, 202 US barrels of Nile Blend crude oil reamined solid in the tanks after discharge. There are some possibilities that low temperature of loading cargo below cloud point and wax appearance temperature at loading time, heating interruption during voyage or discharging, and prohibition of crude oil washing during discharging might influence the cargo solidified. But we concluded that the defect of heating system would most affect the heating cargo solidified locally, and which blocked drain hole of bottom transverse and web frame and they obstruct flow of heating cargo in the tanks.

  • PDF

The impact of corrosion on marine vapour recovery systems by VOC generated from ships

  • Choi, Yoo Youl;Lee, Seok Hee;Park, Jae-Cheul;Choi, Doo Jin;Yoon, Young Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Marine emissions of Volatile Organic Compounds (VOCs) have received much attention because the International Maritime Organization (IMO) requires the installation of vapour emission control systems for the loading of crude oils or petroleum products onto ships. It was recently recognised that significant corrosion occurs inside these vapour emission control systems, which can cause severe clogging issues. In this study, we analysed the chemical composition of drain water sampled from currently operating systems to investigate the primary causes of corrosion in vapour recovery systems. Immersion and electrochemical tests were conducted under simulated conditions with various real drain water samples, and the impact of corrosion on the marine vapour recovery system was carefully investigated. Moreover, corrosion tests on alternative materials were conducted to begin identifying appropriate substitutes. Thermodynamic calculations showed the effects of environmental factors on the production of condensed sulphuric acid from VOC gas. A model of sulphuric acid formation and accumulation by the characteristics of VOC from crude oil and flue gas is suggested.

Development of a Robot System for Monitoring and Repairing a Underground Pipe (지하매설 배관의 탐사 및 도장을 위한 로봇시스템 개발)

  • Yeo, Hee-Joo;Sung, Mun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.346-348
    • /
    • 2007
  • Underground pipe is an instrument to transport rapidly and safely a lot of fluid like gas, oil, water supply and drain system. It acts like blood vessels of human body in a modern industry. As in this country, the pipe facilities have been constructing since 1970's. The pipes constructed for a long time ago are already starting to reveal the problem like corrosion and most of them are built underground. So for companies, the managing of the underground pipes is very hard because it needs high technology and a lot of money. So we made a new robot system to repair and maintain the pipes at a low price. This new robot is devised using pressing wall type to work inside 700${\sim}$900(mm) size pipe. And it has good carrying and working power.

  • PDF

Compliance with GMP and SSOP in College Foodservices by Comparison of Elementary and Middle & High School Foodservices (초, 중.고등학교 급식소와의 비교를 통한 대학 급식소의 GMP 시설 구비 및 SSOP 수행도 조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.3
    • /
    • pp.248-265
    • /
    • 2012
  • A total of 262 dietitians (in 97 college foodservices nationwide, 86 elementary school foodservices, and 79 middle & high school foodservices in the Changwon area) were given a survey questionnaire composed of 18 GMP and 29 SSOP items from May to July, 2011. As a whole, total usage level of GMP facilities (3.65/5 points) and total management level of SSOP (3.86) in college foodservices showed no significant differences compared to those in elementary school foodservices (GMP 3.74, SSOP 4.02) and middle & high school foodservices (GMP 3.75, SSOP 3.95). However, the results of this study suggest that seven items of the GMP facilities and five items of the SSOP should be improved for the development of the HACCP facility model in college foodservices. Those items that showed considerably lower points in GMP were as follows: 'Drain pipes from sinks of the cooking area are connected directly to the drain (3.74)' (P<0.001), 'The grease trap is installed outside the cooking area equipped with an oil separator (3.24)' (P<0.01), 'Entrance and the cooking area are adequately equipped with hand-washing and shoe disinfecting facilities (3.61)' (P<0.001), 'Cooking area, food storage, and dining area are adequately equipped with insect and rodent repellents (3.72)' (P<0.001), 'Cooking areas are equipped with air-conditioning/heating system and ventilation facility for maintenance of temperature and humidity (3.35)' (P<0.05), and 'Toilets for cooking staff only are provided; the its doorways are not directly accessible from the cooking area (3.25)' (P<0.01).

DC-DC Converter of Fixed Duty Ratio Method for 1kW Photovoltaic System (1kW급 태양광 발전용 고정 시비율 방식의 DC-DC 컨버터)

  • Yoo, Ho-Won;Jung, Yong-Min;Lim, Seung-Beom;Lee, Jun-Young;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.46-48
    • /
    • 2008
  • A concern about micro grid connection system is elevated. The reason is that carbon dioxide emission is regionally restricted to prevent the drain of fossil fuel, high oil prices and global warming. The existing photovoltaic DC-DC converter is operated by the full-bridge method. However, the configuration is complicated because a phase shift method is required to raise an efficiency. A photovoltaic DC-DC converter connected with second layered half-bridge converter and boost converter is proposed in this paper. This proposed DC-DC converter is easy to control and has an advantage of reducing the size. Finally, the validity of the proposed converter is verified by the experimentation.

  • PDF

A Study on the DME Application Performance of a High Pressure Fuel Pump for an Electric Controlled Common-rail Compression Ignition Engine (전자제어 커먼레일 압축착화엔진용 고압연료펌프의 DME 적용 성능에 관한 연구)

  • Chung, Jae-Woo;Kim, Nam-Ho;Kang, Jung-Ho;Park, Sang-Wook;Lee, Ho-Kil;Choi, Seung-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.132-140
    • /
    • 2009
  • Recently, the interest in the development of high efficiency Diesel engine technology using alternative fuel has been on the rise and related studies are being performed. Therefore, the DME(Dimethyl Ether), an oxygen containing fuel as an alternative fuel for light oil that can be used for diesel engines since it generates very little smoke. But it is unavoidable that the modification of a fuel supply system in an engine to application of the DME fuel because of DME fuel properties. So, in this study, a DME high pressure pump for a common-rail fuel supply system has been composed and the test results of the pump have been presented. As the results of the tests, it is confirmed that DME pump inlet pressure, pump speed and common-rail pressure effects on the volumetric efficiencies of the pump. Finally, it is defined that the optimum plunger volume of a DME pump has to be extended to the minimum 150% compared to a Diesel pump plunger volume considering DME fuel properties and volumetric efficiencies characteristics at same specifications of the high pressure pump.