• Title/Summary/Keyword: Oil Leakage

Search Result 241, Processing Time 0.039 seconds

Thermal-structural Coupled Field Analysis for Fire Safety Type Ball Valve (화재 안전용 볼밸브의 열·구조 연성해석)

  • Kim, Si-Pom;Lee, Joon-Ho;Lee, Kwon-Hee;Jeon, Rock-Won;Do, Tae-Wan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.28-32
    • /
    • 2011
  • The safety of transporting equipment in a cryogenic condition is one of important problems under the circumstances that the application weight of natural gas is gradually increasing. As a larger disaster may be generated by leakage of oil or gas from valves in case of fire occurrence of a ship, the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. to the design of ball valves satisfying fire safety test's specification(API607) to prevent this. In addition, the present research progressed fire safety tests and compared the test result with numerical analysis results. The Max stress by parts was confirmed through thermal analysis of major parts to evaluate safety. The fire safety test was progressed according to the regulation of API607.

Experiment and Simulation of Acoustic Detection for the Substitute for Sunken Hazardous and Noxious Substances Using the High Frequency Active Sonar (고주파 능동소나를 이용한 저층 침적 위험유해물질 대체물질 음향 탐지 실험 및 모의)

  • Han, Dong-Gyun;Seo, Him Chan;Choi, Jee Woong;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.459-466
    • /
    • 2018
  • Hazardous and Noxious Substances (HNS) are defined as substances that are likely to create a significant impact on human health and marine ecosystem when they are released into the marine environment. Recently, as the volume of HNS transported by ships increases, the rate of leakage accidents also increases. Therefore, research should be conducted to control and monitor sunken materials from the viewpoint of technology development for hazardous material leakage accident response. In this paper, acoustic detection experiments were carried out using HNS substitute materials in order to confirm the possibility of acoustic detection of sunken HNS on the sediment. The castor oil, which has a similar acoustic impedance with chloroform, is used as a substitute. 200 kHz high frequency signals were used to discriminate the reflected signals and measure reflection loss from the interface between water and castor oil. The reflection loss measured is in good agreement with the modeling results, showing a possibility of acoustic detection for sunken HNS.

Development of a Prototype Data Logger System to Operate under Extreme High Pressure

  • Yoo, Nam-Hyun;Rhee, Sang-Yong;Lee, Hyeong-Ok
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • A subsea oil production system must be safely operated for 20-30 years after being installed. Because of the severe conditions of the subsea environment, such as extreme high pressure, low visibility, the possibility of unexpected impact by any object, and corrosion by seawater, subsea oil production systems should be monitored by subsea data logger systems and remotely operated vehicles to check for abnormal vibration and leakage to prevent a catastrophic accident. Because of the severity of subsea environmental conditions and the dominance of a few companies in the market, many people have thought that it would be difficult to develop a subsea data logger system. The primary objectives of the study described in this paper were to analyze existing subsea data logger systems to establish the requirements for a subsea data logger system, implement a prototype subsea data logger system, and conduct a test of the prototype subsea data logger system.

Fire Characteristics for Spill Rate of Light oil and Methanol (경유와 메탄올의 유출속도에 따른 화재특성)

  • Lee, Jung Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

Activity of Essential Oils Against Bacillus subtilis Spores

  • Lawrence, Hayley A.;Palombo, Enzo A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.12
    • /
    • pp.1590-1595
    • /
    • 2009
  • Alternative methods for controlling bacterial endospore contamination are desired in a range of industries and applications. Attention has recently turned to natural products, such as essential oils, which have sporicidal activity. In this study, a selection of essential oils was investigated to identify those with activity against Bacillus subtilis spores. Spores were exposed to 13 essential oils, and surviving spores were enumerated. Cardamom, tea tree, and juniper leaf oils were the most effective, reducing the number of viable spores by 3 logs at concentrations above 1%. Sporicidal activity was enhanced at high temperatures ($60^{\circ}C$) or longer exposure times (up to 1 week). Gas chromatography-mass spectrometry analysis identified the components of the active essential oils. However, none of the major oil components exhibited equivalent activity to the whole oils. The fact that oil components, either alone or in combination, did not show the same level of sporicidal activity as the complete oils suggested that minor components may be involved, or that these act synergistically with major components. Scanning electron microscopy was used to examine spores after exposure to essential oils and suggested that leakage of spore contents was the likely mode of sporicidal action. Our data have shown that essential oils exert sporicidal activity and may be useful in applications where bacterial spore reduction is desired.

A Study for the Safety Regulation of Tank Car for the Hazardous Material - General Oil Tank Car (위험물 수송 탱크 차량의 국내외 안전기준 비교 연구-유류 차량 중심)

  • Kim, Jae-Hoon;Goo, Byung-Chun
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.70-75
    • /
    • 2008
  • Recently, there are so many studies related safety of railway vehicle. But these studies are focused on the passenger car, metro system and high speed train. However, the leakage of hazardous materials may contaminate the environment and cause terrible damage to the ecology, even the human and properties. And so, Safety and security have been already established in many countries, currently they are investing lots of money on the development of technology to prevent accidents. Therefore it is necessary to make a systematic plan and develop safety specifications. In this study, we compared between domestic and international general oil tank car safety regulations for the hazardous materials, and prepare the basic for the making of systematic safety plans and safety regulations for the transport of hazardous materials by tank car.

Optimal Design of A Quick-Acting Hydraulic Fuse Using Design of Experiments and Complex Method (실험계획법과 콤플렉스법에 의한 고성능 유압휴즈의 최적 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.8-14
    • /
    • 2015
  • A quick-acting hydraulic fuse, which is mainly composed of a poppet, a seat, and a spring, must be designed to minimize the leaked oil volume during fuse operation on a line rupture. The optimal design parameters of a quick-acting hydraulic fuse were searched using the design of experiments method and the complex method. First, the $L_{50}(5^4)$ orthogonal array is used to find the robust minimum point among the 625 points of design variables. The search range can then be narrowed around the robust minimum point. Second, the $L_{25}(5^4)$ orthogonal array is used to obtain the variations of the design variables in the narrowed search range. The variations of design variables are used to set the structure of a polynomial equation representing the leakage oil volume of the quick-acting hydraulic fuse. The least squares method is then applied to obtain the coefficients of polynomial equation. Finally, the complex method is used to find the optimal design parameters where the objective function is described by the polynomial equation.

Evacuation characteristic measurement of anti-suck back centering by mini vacuum system (미니 진공시스템을 이용한 역류방지 센터링의 배기 특성 측정)

  • Hong, Gwang-Gi;Go, Seok-Il;Do, U-Ri;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.255-256
    • /
    • 2009
  • The anti suck back centering (ASBC) for preventing backflow of oil for oil rotary pump was designed in the power failure. To evaluate the evacuation characteristics, we manufactured the mini vacuum system, personal computer, AD converter (National instrument, NI-6009), and automatic controller with touch panel for a basis. In this study, we measured the evacuation characteristics of ABSC and analyzed the flow field of viscous flow regime using a commercial software, CFD-ACE+. Also, the leakage of the advaced ASBC for leveling was measured.

  • PDF

Greenhouse Gas Emission Analysis by LNG Fuel Tank Size through Life Cycle

  • Park, Eunyoung;Choi, Jungho
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.393-402
    • /
    • 2021
  • As greenhouse gas emissions from maritime transport are increasing, the International Maritime Organization is continuously working to strengthen emission regulations. Liquefied natural gas (LNG) fuel is less advantageous as a point of CO2 reduction due to the methane leakage that occurs during the bunkering and operation of marine engines. In this study, greenhouse gas emissions from an LNG-fueled ship were analyzed from the perspective of the life cycle. The amount ofmethane emission during the bunkering and operation procedures with various boil-off gas (BOG) treatment methods and gas engine specifications was analyzed by dynamic simulation. The results were also compared with those of other liquid fuel engines. As a result, small LNG-fueled ships without a BOG treatment facility emitted 32% more greenhouse gas than ships utilizing marine gas oil or heavy fuel oil. To achieve a greenhouse gas reduction via a BOG treatment method, a gas combustion unit or re-liquefaction system must be mounted, which results in a greenhouse gas reduction effect of about 25% and 30%. As a result of comparing the amount of greenhouse gas generated according to the BOG treatment method used with each tank size from the perspective of the operating cycle with the amounts from using existing marine fuels, the BOG treatment method showed superior effects of greenhouse gas reduction.

Quality Improvement to Prevent Shifting Error of Tracked Vehicles (궤도차량 변속오류 예방을 위한 품질개선)

  • Yun, Sunghyun;Baek, Hyun Moo;Park, Dong Min;Oh, Dong-Kyo
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.2
    • /
    • pp.297-313
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the causes of shifting errors reported in military tracked vehicles and to improve related quality to prevent recurrence. Methods: A systematic disassembly and inspection of the transmission is carried out and an experimental simulation is conducted to reproduce the shifting error phenomenon. Electrical characteristic tests are subsequently performed and microscopic observation is also carried out on the disassembled connector parts such as pins and fractured surfaces. Results: Oil contamination and swelling deformation are observed in the connector to the vehicle due to oil leakage of its counterpart connector to the transmission. This causes electrical contact failure between both connectors in the fastened state, and it is found that shifting error of the tracked vehicle could occur subsequently. To prevent the recurrence of this phenomenon, comprehensive quality improvement is conducted including product improvement of the wiring harness assembly and strengthening activities for quality control and preventive maintenance. Conclusion: This study is expected to be helpful as a prior case study for cause analysis and recurrence prevention in the event of similar cases in the future.