• Title/Summary/Keyword: Off-current

Search Result 2,261, Processing Time 0.026 seconds

Experimental Study on the Performance Characteristics of Hot-gas Bypass and On-off Defrosting Cycle in a Showcase Refrigeration System (쇼케이스에서 고온가스 바이패스 및 단속운전 제상사이클의 성능특성에 관한 실험적 연구)

  • 김용찬;조홍현;노현일;김영득;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.493-502
    • /
    • 2002
  • During the defrosting process, the temperature in the cabinet of a showcase becomes high as compared to the setting point, which is not desirable for stored foods or materials. It is necessary to develop a more efficient defrosting method to prevent large temperature fluctuation. In this study, the performance of a showcase refrigeration system with three evaporators is investigated by employing a hot-gas bypass defrosting technology in the system under frosting and defrosting conditions. The operating characteristics are compared with those for the on-off defrosting method that has been widely used in current products. As a result, the hot-gas bypass defrosting method shows higher refrigerating capacity and less temperature fluctuation than the on-off method under frosting/defrosting conditions, while the power input is relatively high for the hot-gas bypass method.

Performance Characteristics for Off-design Operation of Micro Gas Turbines (마이크로 가스터빈의 탈설계 운전 성능특성)

  • Hwang, S.H.;Kim, T.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

A study on the suppress method of arc on a electromagnetic contactor (전자개폐기의 arc 억제방안에 관한 연구)

  • 노창주;홍순일;정승환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 1983
  • Nowadays electromagnetic contactors are used for power on-off in various electrical loads. If the severe arc are occurred when power off, the magnetic contactor can not long run because of damage of contactor. In this paper, Authors indicate a method of how to minimize the arc when power off, Authors contrived a electronic circuit which can adjust the demagnetizing point of electro magnetic contactor, and control the demagnetizing point, utilizing our circuit, so as to occur the extinguish of arc at near the AC current zero point which is indispensibly exists. From the results of study, Authors could get confirmations the AC circuit could cut off with occurrence of mininum arc, and that possibility of extensive utilization of our method to hightension circuit.

  • PDF

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

Two Branches of Tsushima Warm Current in the Western Channel of the Korea Strait (韓國海峽 西水道에서 對馬暖流의 2個 支流)

  • Byun, Sang-Kyung;Chang, Sun-Duck
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.200-209
    • /
    • 1984
  • On the basis of oceanographic observation conducted in summer 1982, the flow pattern of the Tsushima Warm Current definitely showed two branches with high surface velocity more than 70 cm/sec in the western channel of Korea Strait. One of the branches, the East Korea Warm Current, found about 8 km off Pusan flows northward along the east coast of Korea and the other branch, located at about 20km off Pusan flows east after passing the Korea Strait. The branching of two flows already occurred before the Tsushima Warm Current reaches the Pusan Tsushima section, and the volume transport and the widths of the two branches are not much different from each other. The number of branches may be controlled by the width of western channel and the flow of two branches may also be related to the variation of layer depth and the widening ratio of widths between the western channel and the Japan Sea (East Sea).

  • PDF

Hydroquenation Effects on the Poly-Si TFT (다결정 실리콘 TFT에 대한 수소처리 영향)

  • 하형찬;이상규;고철기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.1
    • /
    • pp.23-30
    • /
    • 1993
  • Hydrogenation on the top gate and bottom gate Poly-Si TET's was performed by using Nh$_{3}$ plasma and annealing SiN film deposited by PECVD and then the electric characteristics on Poly-Si TET were investigated. As the time of NA$_{3}$ plasma treatment increaes, on/off current ratio gradually increases and the swing value decreases. The trap densities of graim boundaries in Poly-Si decrease very much during the inital 20min of hydrogenation time, and the decreasing scale becomes smaller after 20 min. The electric characteristics of the top gate TFT are better than those of the bottom gate TFT, it is considered due to the defects at the interface between the Poly-Si and the underlayer, SiO$_{2}$. After NH$_{3}$ plasma was treated for 2 hours for the top gate TFT, as the aging time atroon temperature increases on current was not scacely changed and off current decreases more than 1 order. Gate current density recovers to original value after the aging treatment for 8 days and then the electric characteristics are finally improved. It is suggested that the degraded characteristics of gate oxide are improved, from the variations of C-V characteristics with aging time. For the hydrogenation of isothermal and isochronal annealing SiN film deposited by PECVD, the characteristics of Poly-Si TFT are improved with increasing annealing temperature and are not largely changed with increasing annealing time. This results is good in agreement with the hydrogen reduction in Sin film as variations of annealing temperature and time.

  • PDF

Preparation of Epoxy/Organoclay Nanocomposites for Electrical Insulating Material Using an Ultrasonicator

  • Park, Jae-Jun;Park, Young-Bum;Lee, Jae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.3
    • /
    • pp.93-97
    • /
    • 2011
  • In this paper, we discuss design considerations for an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) with a lateral asymmetric channel (LAC) doping profile. We employed a 0.35 ${\mu}M$ standard complementary MOSFET process for fabrication of the devices. The gates to the LAC doping overlap lengths were 0.5, 1.0, and 1.5 ${\mu}M$. The drain current ($I_{ON}$), transconductance ($g_m$), substrate current ($I_{SUB}$), drain to source leakage current ($I_{OFF}$), and channel-hot-electron (CHE) reliability characteristics were taken into account for optimum device design. The LAC devices with shorter overlap lengths demonstrated improved $I_{ON}$ and $g_m$ characteristics. On the other hand, the LAC devices with longer overlap lengths demonstrated improved CHE degradation and $I_{OFF}$ characteristics.

Device Optimization of N-Channel MOSFETs with Lateral Asymmetric Channel Doping Profiles

  • Baek, Ki-Ju;Kim, Jun-Kyu;Kim, Yeong-Seuk;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.15-19
    • /
    • 2010
  • In this paper, we discuss design considerations for an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) with a lateral asymmetric channel (LAC) doping profile. We employed a $0.35\;{\mu}m$ standard complementary MOSFET process for fabrication of the devices. The gates to the LAC doping overlap lengths were 0.5, 1.0, and $1.5\;{\mu}m$. The drain current ($I_{ON}$), transconductance ($g_m$), substrate current ($i_{SUB}$), drain to source leakage current ($i_{OFF}$), and channel-hot-electron (CHE) reliability characteristics were taken into account for optimum device design. The LAC devices with shorter overlap lengths demonstrated improved $I_{ON}$ and $g_m$ characteristics. On the other hand, the LAC devices with longer overlap lengths demonstrated improved CHE degradation and $I_{OFF}$ characteristics.