• 제목/요약/키워드: Off-current

검색결과 2,266건 처리시간 0.032초

Lab scale electrochemical codeposition experiments for comparison to computational predictions

  • Lafreniere, Philip;Zhang, Chao;Simpson, Michael;Blandford, Edward D.
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2025-2033
    • /
    • 2020
  • Signature-based safeguards (SBS) is being developed to assist tradition nuclear material accountancy methods in tracking material in pyroprocessing facilities. SBS involves identifying off-normal scenarios that would result in improper movement of material in a pyroprocessing facilities and determining associated sensor response signatures. SBS investigations are undertaken in the computational space utilizing an electrochemical transport code known as enhanced REFIN with anodic dissolution (ERAD) to calculate the affect of off-normal conditions in the electrorefiner (ER) on material movement. Work is undertaken to experimentally validate the predictions and assumptions made by ERAD for off-normal occurrences. These experiments were undertaken on a benchtop scale and involved operating an electrochemical cell at 10 separate current densities for constant current operations to deposit U and Gd at a W cathode. These experiments were then modeled using ERAD to compare calculated predictions versus analytical experimental results it was found. It was discovered both the experimental and calculated results reflect a trend of increased codeposition of U and Gd with increasing current density. ERAD was thus demonstrated to be useful for predicting trends from anomalous operation but will require further optimization to be utilized as a quantitative design tool.

양성자 조사법에 의한 고속스위칭 사이리스터의 제조 (Fabrication of a fast Switching Thyristor by Proton Irradiation Method)

  • 김은동;장창리;김상철;김남균
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1264-1270
    • /
    • 2004
  • A fast switching thyristor with a superior trade-off property between the on-state voltage drop and the turn-off time could be fabricated by the proton irradiation method. After making symmetric thyristor dies with a voltage rating of 1,600 V from 350 $\mu$m thickness of 60 $\Omega$ㆍcm NTD-Si wafer and 200 $\mu$m width of n-base drift layer, the local carrier lifetime control by the proton irradiation was performed with help of the HI-13 tandem accelerator in China. The thyristor samples irradiated with 4.7 MeV proton beam showed a superior trade-off relationship of $V_{TM}$ = 1.55 V and $t_{q}$ = 15 $\mu$s attributed to a very narrow layer of short carrier lifetime(~1 $\mu$s) in the middle of its n-base drift region. To explain the small increase of $V_{TM}$ , we will introduce the effect of carrier compensation at the low carrier lifetime region by the diffusion current.ffusion current.t.

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;한동희;이운용;임기조;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

서로 다른 소스/드레인 전극물질을 이용한 비정질 In-Ga-Zn-O 박막트랜지스터 성능향상 (Performance Improvement of Amorphous In-Ga-Zn-O Thin-film Transistors Using Different Source/drain Electrode Materials)

  • 김승태;조원주
    • 한국전기전자재료학회논문지
    • /
    • 제29권2호
    • /
    • pp.69-74
    • /
    • 2016
  • In this study, we proposed an a-IGZO (amorphous In-Ga-Zn-O) TFT (thin-film transistor) with off-planed source/drain structure. Furthermore, two different electrode materials (ITO and Ti) were applied to the source and drain contacts for performance improvement of a-IGZO TFTs. When the ITO with a large work-function and the Ti with a small work-function are applied to drain electrode and source contact, respectively, the electrical performances of a-IGZO TFTs were improved; an increased driving current, a decreased leakage current, a high on-off current ratio, and a reduced subthreshold swing. As a result of gate bias stress test at various temperatures, the off-planed S/D a-IGZO TFTs showed a degradation mechanism due to electron trapping and both devices with ITO-drain or Ti-drain electrode revealed an equivalent instability.

소아청소년정신과에서의 허가 초과 및 비승인 약물 처방 (Off-label or Unlicensed Drug Prescriptions in Child and Adolescent Psychiatry)

  • 이소영
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제22권2호
    • /
    • pp.67-73
    • /
    • 2011
  • The purpose of licensing system is to ensure that the medicines are examined for safety, efficacy and quality. Nevertheless, off-label or unlicensed drug usages in pediatric practice is widespread in Korea and worldwide. Psychotropics are one of the most commonly used off-label or unlicensed drugs. The most valid approach to face this dilemma will be to have more evidences from pediatric pharmacological studies. Clinicians, in addition, need to monitor closely their off-label or unlicensed drug prescriptions to minimize the trial and error in practice. Researchers should publish their experiences and provide guidelines. Pharmaceutical companies, regulatory authorities, and consumer organizations should endeavor altogether for the children's right to get safe and efficacious drugs as adults do. Here, the definition as well as the current status of off-label and unlicensed drug prescriptions will be introduced. Critical issues regarding the off label drugs are discussed. In addition, I will describe the present condition as to the off-label and unlicensed drugs in child and adolescent psychiatry and the authorization process of off-label drug prescription in Korea. Lastly, direction we should like to take in this field will be mentioned.

A Sensorless Switched Reluctance Drive System Based on the Improved Simplified Flux Method

  • Li, Zhenguo;Song, Andong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.477-482
    • /
    • 2012
  • This paper describes a new rotor position sensorless control method for SRM drives based on an improved simplified flux linkage method. In the traditional simplified flux linkage method, every phases take turns conduction and current chopping control method is used. Every phases take turns conduction means turning on the incoming working phase while turning off the working phase. This conduction mode causes coupling between turn-on and turn-off angles, which goes against optimal efficiency or torque ripple minimization with sensorless speed control. In the improved simplified flux linkage method, turn-off angle is calculated by flux loop, the turn-on angle can be given arbitrarily and has no relations with the turn-off angle, and the current chopping control method is used. The speed and rotor position can be estimated then. Finally, a sensorless SRM speed control system and an experiment platform with DSP are built and validity of this method is confirmed.

트랩 주입의 구조적 설계에 따른 LIGBT의 전기적 특성 개선에 관한 연구 (Study on the Characteristic Analysis and the Design of the IGBT Structure with Trap Injection for Improved Switching Characteristics)

  • 강이구;추교혁;김상식;성만영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.463-467
    • /
    • 2000
  • In this paper, the new LIGBT structures with trap injection are proposed to improve switching characteristics of the conventional SOI LIGBT. The Simulations are performed in order to investigate the effects of the positiion, whidth and concentration of trap injection region with a reduced minority carrier lifetime using 2D device simulator MEDICI. Their electrical characteristics are analyzed and the optimum design parameters are extracted. As a result of simulation, the turn off time for the model A with the trap injection is $0.78\mus$. These results indicate the improvement of about 2 times compared with the conventional SOI LIGBT because trap injection prevents minority carriers which is stored in the n-drift region during turn off switching. The latching current is $1.5\times10^{-4}A/\mum$ and forward blocking voltage is 168V which are superior to those of conventional structure. It is shown that the trap injection is very effective to reduce the turn off time with a little increasing of on-state voltage drop if its design and process parameters are optimized.

  • PDF

GMA 용접에서 강제적인 위빙이 없는 아크센서 시스템에 관한 연구 (II) -용접선 추적의 토치방향 높이제어- (A Study on the Weavingless Arc Sensor System in GMA Welding (II) -Torch Height Control in Weld Seam Tracking)

  • 안재현;김재웅
    • Journal of Welding and Joining
    • /
    • 제16권3호
    • /
    • pp.55-63
    • /
    • 1998
  • Among the position sensing methods available, the arc sensor which utilizes the electrical signal obtained from the welding arc itself is one of the most prevalently used methods, because it has an advantage that no particular sensing device is necessary and real-time sensing of a groove position is possible directly under the arc. The authors have already developed a seam tracking system that contains a new arc sensor algorithm, which uses the relative welding current variation according to the tip-to-workpiece distance in GMA welding. In this study a torch height control algorithm for automatic weld seam tracking was proposed for completing the previous system, which uses an on-off control technique. To implement the torch height control algorithm during weld seam tracking the system parameters which include 2nd averaging range, weighting factor for 2nd moving averaging, and Z-directional basic compensation distance were determined by experimental analysis. Finally the two different height control methods, one is simple on-off control and the other on-off control using a reference current value , were compared in their tracking abilities.

  • PDF

Interleaved ZVS Resonant Converter with a Parallel-Series Connection

  • Lin, Bor-Ren;Shen, Sin-Jhih
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.528-537
    • /
    • 2012
  • This paper presents an interleaved resonant converter with a parallel-series transformer connection in order to achieve ripple current reduction at the output capacitor, zero voltage turn-on for the active switches, zero current turn-off for the rectifier diodes, less voltage stress on the rectifier diodes, and less current stress on the transformer primary windings. The primary windings of the two transformers are connected in parallel in order to share the input current and to reduce the root-mean-square (rms) current on the primary windings. The secondary windings of the two transformers are connected in series in order to ensure that the transformer primary currents are balanced. A full-wave diode rectifier is used at the output side to clamp the voltage stress of the rectifier diode at the output voltage. Two circuit modules are operated with the interleaved PWM scheme so that the input and output ripple currents are reduced. Based on the resonant behavior, all of the active switches are turned on under zero voltage switching (ZVS), and the rectifier diodes are turned off under zero current switching (ZCS) if the operating switching frequency is less than the series resonant frequency. Finally, experiments with a 1kW prototype are described to verify the effectiveness of the proposed converter.

Continuous Conduction Mode Soft-Switching Boost Converter and its Application in Power Factor Correction

  • Cheng, Miao-miao;Liu, Zhiguo;Bao, Yueyue;Zhang, Zhongjie
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1689-1697
    • /
    • 2016
  • Continuous conduction mode (CCM) boost converters are commonly used in home appliances and various industries because of their simple topology and low input current ripples. However, these converters suffer from several disadvantages, such as hard switching of the active switch and reverse recovery problems of the output diode. These disadvantages increase voltage stresses across the switch and output diode and thus contribute to switching losses and electromagnetic interference. A new topology is presented in this work to improve the switching characteristics of CCM boost converters. Zero-current turn-on and zero-voltage turn-off are achieved for the active switches. The reverse-recovery current is reduced by soft turning-off the output diode. In addition, an input current sensorless control is applied to the proposed topology by pre-calculating the duty cycles of the active switches. Power factor correction is thus achieved with less effort than that required in the traditional method. Simulation and experimental results verify the soft-switching characteristics of the proposed topology and the effectiveness of the proposed input current sensorless control.