• Title/Summary/Keyword: Oblique projection

Search Result 44, Processing Time 0.026 seconds

THE STUDY OF THE INTERPRETATION OF THE TMJ RADIOGRAPHY USING SUBTRACTION TECHNIQUE (Subtraction법을 이용한 악관절 X-선사진 판독에 관한 연구)

  • Na Choon-Wha;Yoo Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.175-181
    • /
    • 1987
  • The purpose of this study is to know the value of the photographic subtraction technic in the transcranial oblique lateral projection of the TMJ. The author examined the transcranial oblique lateral projection radiographs which comprise 50 cases of 32 persons, compared the transcranial oblique lateral projection films and those subtraction films. The following results were obtained. 1) The condyle at closed jaw position had showed a reversed tone image, but the condyle at the opening position had showed a re-reversed ordinary image. Both condyles had showed one subtraction film because radiographic interpretation of TMJ was easy. 2) On 50 cases of subtraction films, 46 cases had showed same radiographic images compared with trascranial oblique lateral projection films. Four cases (3 cases of erosion, 1 cases of sclerosis) had showed additional changes of images so that capability of interpretation was improved.

  • PDF

OBLIQUE PROJECTIONS AND SHIFT-INVARIANT SPACES

  • Park, Sang-Don;Kang, Chul
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.5_6
    • /
    • pp.1207-1214
    • /
    • 2008
  • We give an elementary proof of one of the main results in [H.O. Kim, R.Y. Kim, J.K. Lim, The infimum cosine angle between two finitely generated shift-invariant spaces and its applications, Appl. Comput. Har-mon. Anal. 19 (2005) 253-281] concerning the existence of an oblique projection onto a finitely generated shift-invariant space along the orthogonal complement of another finitely generated shift-invariant space under the assumption that the generators generate Riesz bases.

  • PDF

COMPARATIVE STUDY OF TEMPOROMANDIBULAR JOINT RADIOGRAMS USING SOME RADIOGRAPHIC PROJECTIONS (촬영술식에 따른 악관절 방사선 사진상의 비교연구)

  • Kim kwang-In;Kim Han-Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.65-72
    • /
    • 1991
  • For the enhancement of a comprehension in temporomandibular joint radiographs, the author has compared and analysed the roentgenographic images of the temporomandibular joint of human dry skull which was taken by submentovertex projection, panoramic radiography, oblique lateral transcranial projection, corrected anterio-posterior tomogram and corrected lateral tomogram. The obtained results were as follows. 1. The submentovertex projection represented in detail the both poles and the posterior surface of the condylar head of the mandible. 2. The oblique lateral transcranial projection represented the articular space, the outer contour of the condylar head and the position of the condylar head within the mandibular fossa, but the relationship of the temporomandibular joint was not revealed accurate, because of the oblique direction of a central ray in taking radiographs. 3. The corrected antero-posterior tomogram was superior method in representation of roent- genographic images of the superior surface and the both poles of the condylar head and the corrected lateral tomogram was considered as the most accurate method among some radiographic techniques for the interpretation of articular space and condyle-fossa relationship. 4. It was possible to observe three-dimensionally the head of condyle with the combinated use of submentovertex projection, corrected antero-posterior tomogram and corrected lateral tomogram.

  • PDF

Morphological study on abdominal organs of healthy cats using omnidirectional radiography and fluoroscopy (다각도 방사선촬영 및 투시법을 이용한 정상 고양이 장기의 형태학적 연구)

  • Shin, Sa-kyeng;Hirose, Tsuneo;Sato, Motoyoshi;Miyahara, Kazuro
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.949-966
    • /
    • 1996
  • To establish the method for the most effective radiography and fluoroscopy, the abdominal organs of cats were investigeted using omnidirectional angles with the center of the body as the axis using an omnidirectional protective shielding X-ray system and a $360^{\circ}$ rotary restraint unit for use in small animals. The organs examined were the diaphragm, liver, stomach, colon, spleen and kidney. The results obtained in the present study were as follows: 1. Regardless of gas in the stomach present or not, it was feasible to distinguish the left and right crura in the lumbar portion of diaphragm in the oblique projection inclined over $30^{\circ}$ and under $90^{\circ}$ from the lateral projection. 2. Outlines of the exterior left lobe and the interior right lobe of the liver were observed in the oblique image inclined up to $60^{\circ}$ from the lateral image, while that of the exterior right lobe was noted in the oblique image inclined up to $60^{\circ}$ from the ventrodorsal-dorsoventral images. 3. It was necessary to have gas present in the stomach for detailed morphological observations of the stomach. It was most clearly observed in the right $30^{\circ}$ ventral-left dorsal oblique projection($120^{\circ}$ image) and the left $60^{\circ}$ dorsal-right ventral oblique projection($300^{\circ}$ image). 4. Morphology of the colon was observable in detail by the oblique projection inclined over $30^{\circ}$ from the lateral projection. 5. To observe the whole spleen it was required to have images from the ventrodorsal projection ($90^{\circ}$ image) to the right $60^{\circ}$ ventral-left dorsal oblique projection ($150^{\circ}$ image) as well as those from the dorsoventral projection ($270^{\circ}$ image) to the left-right lateral projection $0^{\circ}$ image). 6. Dorsal and ventral sides of the kidney were observable in the oblique images inclined $30^{\circ}$ from the lateral image. 7. Considering above findings collectively, it was thought that the results of present study might be useful for the analysis of abnormalies in each organ of cat.

  • PDF

OBLIQUE PROJECTION OPERATION FOR NEAR OPTIMAL IMAGE RESIZING

  • Lee, Chulhee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.209-212
    • /
    • 1996
  • In this paper, we propose to re-size images using an oblique projection operator instead of the orthogonal one in order to obtain faster, simpler, and more general algorithms. The main advantage is that it becomes perfectly feasible to use higher order models(e.g., splines of degree n 3). We develop the theoretical background and present a simple and practical implementation procedure that uses B-splines. Experiments show that the proposed algorithm consistently outperforms the standard interpolation method and that it essentially provides the same performance as the optimal procedure (least squares solution) with considerably less computations.

  • PDF

High-Contrast Projection Screen

  • Kuo, Huei Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1430-1432
    • /
    • 2008
  • We have developed a high-contrast ambient-light rejection projection screen with surface micro-structures for front and rear projection displays with an oblique-angle projector. We have fabricated prototype screens that show a better than $10{\times}$ improvement in contrast compared to a matte-white screen under various ambient lighting conditions and screen luminance.

  • PDF

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

RADIOGRAPHIC STUDY ON THE BONY CHANGES OF MANDIBULAR CONDYLE HEAD IN TEMPOROMANDIBULAR DISORDER PATIENTS (악관절장애환자에 있어서 하악과두의 골변화양상에 관한 방사선학적 연구)

  • Park Moo Soon;You Dong Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.151-159
    • /
    • 1989
  • The author has studied radiographic bony cnages of mandibular condyle head in temporomandibular disorder patients using Oblique lateral transcranial projection, Orthopantomography, and Tomography. The bony change types and the frequencies of occurrence and the incidences of bony changes in three different radiographic techniques were examined. The coincidences of bony change types between the Oblique lateral transcranial projection and the lateral part of Tomogram, the Orthopantomogram and the medial part of Tomogram were also examined. The results were as follows: 1. The mean age of patients was 31.7 years and under 40 years were 24 patients, women werw 27 patients, men were 4patients. 2. The observable case of bony changes in all three radiographic techniques were 19 cases (50%) of 38 cases and the observable cases of bony changes in only Tomography were 5 cases(13.2%) 3. The most frequent radiographic bony change type was osteophyte and next orders were flattening, erosion, concavity. 4. The positional incidences of bony change in Tomogram were 31 cases in lateral part and 27 cases in central part. 5. The coincidence of bony change types between the Oblique lateral transcranial projection and the lateral part of Tomogram was 80%, and the coincidence between the Orthopantomogram and the medial part or Tomogram was 76.0%.

  • PDF

Usefulness of an Auxiliary Tool for Hand Radiography by Using 3D Printing (3D 프린팅을 이용한 손 엑스선 검사 보조도구의 유용성)

  • Ji-Won Kim;Bon-Yeoul Koo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.485-491
    • /
    • 2023
  • As an auxiliary tool for fixing the patient's posture when taking an X-ray, sponges with high radiolucencies are laminated in various thicknesses. This study aimed to evaluate the usefulness of an auxiliary tool for hand oblique projection X-ray by manufacturing it with a uniform thickness by 3D printing and comparing it with existing sponge tools. In the auxiliary tool, radiolucency was measured at the stairs where each finger was located, and pixel information values were compared in the digital imaging and communications in medicine(DICOM) image. Contrast to noise ratio(CNR) and signal to noise ratio(SNR) were compared by shooting the hand phantom and the auxiliary tool together. As the thickness of the sponge tool increased, radiolucency decreased by 15.52% and pixel information value increased by 20.61%. The transmittance of the 3D printing tool increased by 0.82%, and the pixel information value differed by 5.66%. CNR and SNR increased by 20.03% and 22.42% in 3D printing compared to existing sponge tools. while taking hand oblique projection, maintaining the thickness of the auxiliary tool uniformly through 3D printing maintains high radiolucency and minimal impact on medical images, and increases CNR and SNR, making it useful as an auxiliary tool for taking hand oblique projection.

Color Image Scaling Using Oblique Projection (경사 투영을 사용한 컬러 이미지 스케일링)

  • 김준목;정원용
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.53-56
    • /
    • 2000
  • 본 논문에서는 컬러이미지의 스케일링(scaling)을 위해 경사투영방법을 사용하여 기본적인 보간방법, 최소자승근사(least square approximation)의 결과들과 비교하여 보았다. 경사투영방법은 최소의 근사오차(approximation error)를 제공하는 수직투영(orthogonal projection)방법과 유사한 결과를 제공하며 전처리 필터 디자인에 자유성을 부여하고, 좀 더 일반화된 형태의 보간 방법이다. 사용된 방법을 기본적인 보간법들과 비교하여 보았을 때 더 좋은 PSNR의 결과를 얻을 수 있었으며 최소자승근사 방법과 유사한 결과들을 얻을 수가 있었다.

  • PDF