• Title/Summary/Keyword: Oblique Image

Search Result 138, Processing Time 0.021 seconds

Optimal Shoulder Position for Visualization of SLAP Ⅱ lesion on MR-Arthrography (SLAP Ⅱ 병변의 진단을 위한 관절 조영 자기 공명 영상에서 견관절 위치에 따른 비교)

  • Lee Young-Soo;Shin Dong-Bae;Park Soo-Jin;Kim Jin-Yong;Kim Hee-Sang;Ha Du-Hae
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.95-101
    • /
    • 2000
  • Purpose : The purpose of this study was to evaluate the efficacy of oblique coronal MR images, oblique axial images of neutral, internal rotation and external rotation positions in the diagnosis of SLAP Ⅱ lesion. Materials and Methods: MR arthrography of the glenohumeral joint was evaluated retrospectively in 16 patients(16 shoulders) who underwent arthroscopic surgery(mean age; 38 years old, Male; 13, Female; 3). Oblique coronal fat-suppressed Tl-weighted spin echo images were performed with each shoulder in the neutral position of the arm and oblique axial images were performed in neutral, internal and external rotations of the arm respectively. The preoperative findings of MR were classified as definite tear, possible tear and no tear. Arthroscopic findings were correlated with MR findings of several different position of the arm. Results: Arthroscopic surgery revealed 8 SLAP Ⅱ lesion, 2 SLAP I lesion, and 6 normal superior labrum respectively. The accuracy of diagnosis in the 8 SLAP Ⅱ lesion were high on oblique axial image in external rotation which were interpreted as 8 definite tear, to compare with oblique axial images in neutral position which were interpreted as 4 definite tear, 3 possible tear, 1 no tear. The 6 normal superior labrum lesion were interpreted as no tear in all three position. The 2 SLAP I lesion were interpreted as 1 definite tear, 1 no tear on oblique axial image in neutral position and 1 definite tear, 1 possible tear on oblique axial image in external rotation. Conclusion: This study showed that axial MR images in external rotation of the arm combined with oblique coronal images have proved to be effective to detect SLAP Ⅱ lesion, and should be considered in imaging protocol for MR arthrography of the SLAP Ⅱ lesion.

  • PDF

Morphological study on abdominal organs of healthy cats using omnidirectional radiography and fluoroscopy (다각도 방사선촬영 및 투시법을 이용한 정상 고양이 장기의 형태학적 연구)

  • Shin, Sa-kyeng;Hirose, Tsuneo;Sato, Motoyoshi;Miyahara, Kazuro
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.949-966
    • /
    • 1996
  • To establish the method for the most effective radiography and fluoroscopy, the abdominal organs of cats were investigeted using omnidirectional angles with the center of the body as the axis using an omnidirectional protective shielding X-ray system and a $360^{\circ}$ rotary restraint unit for use in small animals. The organs examined were the diaphragm, liver, stomach, colon, spleen and kidney. The results obtained in the present study were as follows: 1. Regardless of gas in the stomach present or not, it was feasible to distinguish the left and right crura in the lumbar portion of diaphragm in the oblique projection inclined over $30^{\circ}$ and under $90^{\circ}$ from the lateral projection. 2. Outlines of the exterior left lobe and the interior right lobe of the liver were observed in the oblique image inclined up to $60^{\circ}$ from the lateral image, while that of the exterior right lobe was noted in the oblique image inclined up to $60^{\circ}$ from the ventrodorsal-dorsoventral images. 3. It was necessary to have gas present in the stomach for detailed morphological observations of the stomach. It was most clearly observed in the right $30^{\circ}$ ventral-left dorsal oblique projection($120^{\circ}$ image) and the left $60^{\circ}$ dorsal-right ventral oblique projection($300^{\circ}$ image). 4. Morphology of the colon was observable in detail by the oblique projection inclined over $30^{\circ}$ from the lateral projection. 5. To observe the whole spleen it was required to have images from the ventrodorsal projection ($90^{\circ}$ image) to the right $60^{\circ}$ ventral-left dorsal oblique projection ($150^{\circ}$ image) as well as those from the dorsoventral projection ($270^{\circ}$ image) to the left-right lateral projection $0^{\circ}$ image). 6. Dorsal and ventral sides of the kidney were observable in the oblique images inclined $30^{\circ}$ from the lateral image. 7. Considering above findings collectively, it was thought that the results of present study might be useful for the analysis of abnormalies in each organ of cat.

  • PDF

PSP Pressure Field Visualization of an Oblique Impinging Jet (경사충돌제트의 PSP 압력장 가시화)

  • Kang Jong Hoon;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.10-13
    • /
    • 2004
  • The PSP(pressure sensitive paint) technique has recently received a large attention as a new revolutionary optical method to measure absolute pressure distribution on a model surface. The PSP technique can be applied to quantitatively investigate flow structure using a CCD camera and image processing technique. In the static calibration, the luminescent intensity of PSP coatings was measured from 0kPa to 11kPa with 0.5, 1, 2kPa increments. In this study, the low-pressure PSP technique was applied to an oblique impinging jet to measure pressure field variations on the impingement plate with varying angle of an oblique jet. The flow structure over the impingement plate was visualized using a surface tracing method. As a result, the detail pressure field distributions of the oblique low-speed impinging jet were visualized effectively using the PSP technique.

  • PDF

Algorithm for Discrimination of Brown Rice Kernels Using Machine Vision (기계시각을 이용한 현미의 개체 품위 판별 알고리즘 개발)

  • 노상하;황창선;이종환
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.295-302
    • /
    • 1997
  • An ultimate purpose of this study was to develop an automatic system for brown rice quality inspection using image processing technique. In this study emphasis was put on developing an algorithm for discriminating the brown rice kernels depending on their external quality with a color image processing system equipped with an adaptor magnifying the input image and optical fiber for oblique lightening. Primarily, geometical and optical features of images were analyzed with paddy and the various brown rice kernel samples such as a sound, cracked, peen-transparent, green-opaque, colored, white-opaque and brokens. Secondary, geometrical and optical parameters significant for identifying each rice kernels were screened by a statistical analysis(STEPWISE and DISCRIM procedure, SAS wer. 6) and an algorithm fur on- line discrimination of the rice kernels in static state were developed, and finally its performance was evaluated. The results are summarized as follows. 1) It was ascertained that the cracked kernels can be detected when e incident angle of the oblique light is less than 2$0^{\circ}C$ but detectivity was significantly affected by the angle between the direction of the oblique light and the longitudinal axis of the rice kernel and also by the location of the embryo with respect to the oblique light. 2) The most significant Parameters which can discriminate brown rice kernels are area, length and R, B and r values among the several geometrical and optical parameters. 3) Discrimination accuracies of the algorithm were ranged from 90% to 96% for a sound, cracked, colored, broken and unhulled, about 81 % for green-transparent and white-opaque and 75 % for green-opaque, respectively.

  • PDF

The usability of the image according to the frequency encoding gradient direction conversion in fixation using the non magnetic metal screw (비 자성 금속 screw를 이용한 고정술에서 주파수 부호화 경사 방향 변환에 따른 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-So
    • Journal of Digital Contents Society
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Because of causing the geometrical transformation of the magnetic field, the patient implementing the fixation using the nonmagnetic metal screw causes the magnetic susceptibility artifact at an image. Thus, in this research, the distortion measure of the image according to the frequency oblique direction conversion tried to be compared in the magnetic susceptibility artifact occurence. First, the itself phantom inserting the nonmagnetic metal screw of the titanium component was made and the region of interest was set up and the frequency oblique direction the anterior - back side was converted to the right-to-left direction in the axial image and a right-to-left was converted to the upper side - bottom side in the coronal plane and the upper - bottom side was converted to the anterior - back side in the sagittal plane and the distortion measure of the region of interest was compared, it observed. In a result, when converting the frequency oblique direction, the distortion difference of the region of interest could be confirmed and it is considered to enhance the diagnostics efficiency changing the oblique direction appropriately.

Dark Field Digital Holographic Microscopy Based on Two-lens 360-degree Oblique Illumination

  • Zhang, Xiuying;Zhao, Yingchun;Yuan, Caojin;Feng, Shaotong;Wang, Lin
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • In this paper we propose a dark-field digital holographic microscopy system based on 360-degree oblique illumination. This setup is constructed without using a dark-field objective. The principle of 360-degree oblique illumination of vortex beam and dark-field digital holographic microscopy are introduced theoretically and experimentally. By analyzing the reconstructed image of a dark-field digital hologram of a USAF 1951 target, it is proved that the imaging resolution can be improved by this method. And also, comparison and analysis are made on the reconstructed image of a bright-dark field digital hologram of a pumpkin stem slice, the result shows that the imaging contrast is also enhanced with this method, and it is effective for dark-field digital holographic microscopy imaging of large transparent biological samples.

Comparison of the Abdominal Muscle Thickness during Abdominal Hollowing Exercise According to the Visual Feedback Method (할로잉 운동 시 시각적 피드백 방법에 따른 복근 두께에 미치는 영향 비교)

  • Kim, Ha-Rim;Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.107-113
    • /
    • 2021
  • PURPOSE: Selective strengthening of the transverse abdominis muscle (TrA) during abdominal hollowing makes an important contribution to the stability and control of the spine. This study examined the effects of abdominal hollowing exercise (AHE) according to the visual feedback method on the external oblique, internal oblique, and transverse abdominis muscles. METHODS: Twenty healthy subjects were assigned randomly to an AHE with visual feedback from real-time ultrasound image (group A, n = 10), AHE with visual feedback with pressure biofeedback unit (group B, n = 10). Both groups underwent 20 min of AHE with visual feedback once daily, five days/week for two weeks. The changes in the muscle thickness of the TrA, internal oblique abdominal muscle (IO), and external oblique abdominal muscle (EO) were measured by ultrasonography. RESULTS: The thickness of TrA was changed significantly in both groups (p < .05). However, the lowest minimal detectable changes were achieved in Group A. The thickness of the IO and EO muscles in group A was changed significantly, but there were no significant changes in group B. CONCLUSION: Both visual feedback methods were effective for strengthening the TrA muscles selectively. Nevertheless, AHE with visual feedback using real-time ultrasound images may be more useful in trA muscle contraction.

Generation of Mosaic Image using Aerial Oblique Images (경사사진을 이용한 모자이크 영상 제작)

  • Seo, Sang Il;Park, Byung-Wook;Lee, Byoung Kil;Kim, Jong In
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.145-154
    • /
    • 2014
  • The road network becomes more complex and extensive. Therefore, the inconveniences are caused in accordance with the time delay of the restoration of damaged roads, demands for excessive costs on information collection, and limitations on acquisition of damage information of the roads. Recently, road centric spatial information is gathered using mobile multi sensor system for road inventory. But expensive MMS(Mobile Mapping System) equipments require high maintenance costs from beginning and takes a lot of time in the data processing. So research is needed for continuous maintenance by collecting and displaying the damaged information on a digital map using low cost mobile camera system. In this research we aim to develop the techniques for mosaic with a regular ground sample distance using successive image from oblique camera on a vehicle. For doing this, mosaic image is generated by estimating the homography of high resolution oblique image, and the ground sample distance and appropriate overlap are analyzed using high resolution aerial oblique images which contain resolution target. Based on this we have proposed the appropriate overlap and exposure interval for mobile road inventory system.

The Effect of Pelvic Floor Muscle Contraction with Image Feedback on Abdominal Muscle Thickness (영상피드백을 적용한 골반저근 수축이 복부 근 두께에 미치는 영향)

  • Kim, Jin-Hee;Kim, Nan-Soo;Jang, Jun-Hyeok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.533-539
    • /
    • 2012
  • PURPOSE: The purpose of this study was to investigate the effect of pelvic floor muscle contraction with image feedback on Abdominal muscle thickness. METHODS: Twenty three adults participated in this study. Abdominal muscle thickness was measured by ultrasound in three condition(rest, pelvic floor muscle contraction, pelvic floor muscle contraction with image feedback). Subjects was contraction pelvic floor muscle by general method. And ultrasound(convex probe, 3.5MHz) was used to image feedback for selective pelvic floor muscle contraction. One-way ANOVA was used to compare abdominal muscle thickness in three condition. RESULTS: There was no significant difference in external oblique(p=.514) and internal oblique muscle(p=.250) thickness by three condition. There was significant difference in transverse abdominis thickness by three condition (Transverse abdominis thickness was highest while Pelvic floor muscle contraction than pelvic floor muscle contraction with image feedback and rest.)(p=.000). CONCLUSION: This study shows that pelvic floor muscle contraction with image feedback increase the thickness of transverse abdominis lesser than general pelvic floor muscle contraction.

An Investigation on Heat transfer Characteristics of Inclined Wall Attaching Offest jet (경사진 벽부착 제트의 열전달 특성에 대한 연구)

  • 심재경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.200-209
    • /
    • 1998
  • Experiments have been conducted to determine heat transfer characteristics for a two-dimen-sional turbulent wall attaching offset jet at different oblique angles to a flat surface. The local Nusselt number distributions were measured using liquid crystal as a temperature sensor. Wall static pressure coefficient profiles were measured at the Reynolds number Re 53200(based on the nozzle width, D) the offset ratio H/D from 2.5 to 10 and the oblique angle a from $0^{\circ}$, to $40^{\circ}$ It is observed that the maximum Nusselt number point occurs slightly upstream of time-averaged reattachment point for all oblique angles. The correlations between the maximum Nusselt number and Reynolds number offset ration and oblique angle are presented.

  • PDF