• Title/Summary/Keyword: ORP시스템

Search Result 28, Processing Time 0.021 seconds

A Study on the ORP Modeling in SBR Process for Nitrogen Removal: Polynomial Neural Network Is Employed (질소제거를 위한 SBR 공정운전에서 ORP 모델링에 관한 연구: 다항식 뉴럴네트워크 기법 중심)

  • 김동원;박영환;박귀태
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.4
    • /
    • pp.221-225
    • /
    • 2004
  • This paper shows the application of artificial intelligence technique such as polynomial neural network in modeling and identification of sequencing batch reactor (SBR). A wastewater treatment process for nitrogen removal in the SBR is presented. Simulation results have shown that the nonlinear process can be modeled reasonably well by the Present scheme which is simple but efficient.

Rehabilitation Priority Decision Model for Sewer Systems (하수관거시스템 개량 우선순위 결정 모형)

  • Lee, Jung-Ho;Park, Moo-Jong;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.7-14
    • /
    • 2008
  • The main objective of sewer rehabilitation is to improve its function while eliminating inflow/infiltration (I/I). If we can identify the amount of I/I for an individual pipe, it is possible to estimate the I/Is of sub-areas clearly. However, in real, the amount of I/I for an individual pipe is almost impossible to be obtained due to the limitation of cost and time. In this study, I/I occurrence of each sewer pipe is estimated using AHP (Analytic Hierarch Process) and RPDM (Rehabilitation Priority Decision Model for sewer system) was developed using the estimated I/I of each pipe to perform the efficient sewer rehabilitation. Based on the determined amount of I/I for an individual pipe, the RPDM determines the optimal rehabilitation priority (ORP) using a genetic algorithm for sub-areas in term of minimizing the amount of I/I occurring while the rehabilitation process is performed. The benefit obtained by implementing the ORP for rehabilitation of sub-areas is estimated by the only waste water treatment cost (WWTC) of I/I which occurs during the sewer rehabilitation period. The results of the ORP were compared with those of a numerical weighting method (NWM) which is the decision method for the rehabilitation priority in the general sewer rehabilitation practices and the worst order which are other methods to determine the rehabilitation order of sub-areas in field. The ORP reduced the WWTC by 22% compared to the NWM and by 40% compared to the worst order.

Characteristics of Electrolyzed Water Manufactured from Various Electrolytic Diaphragm and Electrolyte (전기분해 격막 및 전해액에 따른 전해수의 특성 비교)

  • 정진웅;김종훈;김병삼;정승원
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2003
  • This study was carried out to investigate the efficacy of surface sterilization and the physicochemical properties of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Physical properties of electrolyzed water manufactured from the diaphragm system were the most effective at the following conditions; the distance between diaphragms was 1.0 mm and the supplying rate of 20% NaCl was 6 mL/min. The ORP, HClO content and pH at above conditions were 1,170 mV, 100 ppm and 2.5, respectively. And two stage electrolyzed system was more effective than one stage electrolyzed water manufactured from non-diaphragm system, with 4 mL/min supplying rate of 20% NaCl, was similar to the most effective diaphragm system. But ORP, HClO content and pH were abut 800 mV, 200 ppm and 9 level, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORP of 750 mV in non-diaphragm system and 1,150 mV in diaphragm system, and HClO content of 100 ppm. Twelve kinds of microorganism tested were sterilized within 30 seconds from initial total counts of 10$\^$5/∼10$\^$6/cfu/ml by electrolyzed water. Though the ORP and HCIO contents of electrolyzed water manufactured from various electrolyte were higher in order of NaCl>KCl>CaCl$_2$, there were no difference between the electyolytes in the efficacy of sterilization. Salmonella typhi and Vibrio Proteolyticus were also sterilized by electrolyzed water manufactured from elctrolytes of NaCl CaC1$_2$and KCl

에코콘 탐사시스템을 이용한 지반특성 및 지반환경 조사

  • 정하익;김영진;홍승서;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.67-70
    • /
    • 2004
  • The purpose of this study is to develop the investigation technology of ground characteristics and environments using eco cone penetration system. The underground environments of landfill was investigated and analyzed by this eco cone system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in eco cone penetration system. This eco cone penetration system provides a continuous profile of measurements in underground, and provides repeatable, reliable and cost effective results for investigation of clean and contaminated ground.

  • PDF

Geo-Environmental Site Investigation for Underground Oil Storage facilities and Landfill Using the Envi-Cone Penetrometer System (환경콘 관입시스템을 이용한 유류저장소 및 폐기물매립지 지중환경특성 조사)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.33-36
    • /
    • 2000
  • The purpose of this study investigated underground oil storage(USTs) and Landfill using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground.

  • PDF

에코콘 관입시스템을 이용한 지반의 현장원위치 수리전도도 측정

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.262-265
    • /
    • 2004
  • The purpose of this study is to investigate environmental characteristics and in-situ hydraulic conductivity by eco cone penetration system. The underground environments and permeability of site was investigated and analyzed by this eco cone system. The electrical resistivity, pH, ORP, temperature and hydraulic conductivity were measured by eco cone penetration system. This eco cone penetration system provides a continuous environment and permeability profiles in underground, and provides reliable results for investigation of normal and contaminated ground.

  • PDF

Characteristics of Mineral Mg Dissolving Sensor in Edible Water using GMR-SV Device (거대자기저항 스핀밸브 소자를 이용한 음용수 미네랄 Mg 용해센서 특성 연구)

  • Lee, Ju-Hee;Kim, Da-Woon;Kim, Min-Ji;Park, Kwang-Seo;Kang, Joon-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.5
    • /
    • pp.174-179
    • /
    • 2008
  • The measurement dissolution sensor system using GMR-SV device with magnetic sensitivity of 0.8 %/Oe and Mg-film thick of 200 nm and Mg-foil thick of 50 mm was fabricated and characterized. During the water dissolving process of Mg-film and Mg-foil, the subtle variation of magnetic field by the decrease of current in solenoid was detected by the GMR-SV sensor. The variations of Mg bubble number and ORP as a function of time for three different kinds of edible, tap, and distilled water, are measured and compared. A After 45 min, the speed of fast dissolving Mg was shown the order of edible > tap > DI water. The variation of output magnetoresistance as a function of dissolved time of Mg-film and Mg-foil for edible water, which is composed of mineral content of $0.8{\sim}5.4\;mg/l$ was investigated. The response times for the dissolution in edible water were 5 min and 20 min, respectively. From the measurement of dissolving time and speed for Mg-film and Mg-foil using GMR-SV device, the mineral Mg sensor system in edible water can be possible to develop.

Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process (하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감)

  • Ahn, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

Design of Monitoring System for Integrated Management of On-site Wastewater Treatment Plants and Development of its Operation Program (소규모 현장 오수처리시설의 통합관리를 위한 모니터링 시스템 설계 및 운영 프로그램 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.137-140
    • /
    • 2002
  • The monitoring system for integrated management of on-site wastewater treatment plants(biofilter) was designed and its operation program was developed. In design process, the research on monitoring parameters which will be able to represent condition and operation of the pilot plants was accomplished, and these parameters came to reveal with ORP(Oxidation-Reduction Potential), water level, pump and power on/off. Proposed monitoring system is composed with measurement, control, communication and display device, and PCB(Prototype Circuit Boards) and microcontroller (PIC16F877) technique are applied to its design of control device for performing specific function. also, The operation program of PC setup is developed in order to provide a convenience to the manager.

  • PDF

Real-time Chemical Monitoring System using RGB Sensor toward PCB Manufacturing (PCB 제조공정을 위한 화학약품 용액의 실시간 모니터링 시스템)

  • An, Jong-Hwan;Lee, Seok-Jun;Kim, Lee-Chui;Hong, Sang-Jeen
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.397-401
    • /
    • 2008
  • Most of the topic in PCB industry was about increasing the volume of product for the development of electronics in numerous industrial application area. However, it has been emerged that yield improvement quality manufacturing via detecting any suspicious process in order to minimize the scrapped product and material waste. In addition, recently, restriction of hazardous substances (RoHS) claims that electronic manufacturing environment should reduce the harmful chemicals usage, thus the importance of monitoring copper etchant and detecting any mis-processing is crucial for electronics manufacturing. In this paper, we have developed real-time chemical monitoring system using RGB sensor, which is simpler but more accurate method than commercially utilized oxidation reduction potential (ORP) technique. The developed Cu etchant monitoring system can further be utilized for copper interconnect process in future nano-semiconductor process.